My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3727 MCDOUGALL AVE 2018-03-13
>
Address Records
>
MCDOUGALL AVE
>
3727
>
3727 MCDOUGALL AVE 2018-03-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/13/2018 8:00:36 AM
Creation date
3/13/2018 7:57:34 AM
Metadata
Fields
Template:
Address Document
Street Name
MCDOUGALL AVE
Street Number
3727
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
168
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> A copy of NFPA 72 Record of Completion form must be filled out prior to final occupancy (NFPA 72, <br /> 2010 Edition, Chapter 10,page 114). Call for design requirements per Authority Having Jurisdiction. <br /> Automatic smoke detection is required. <br /> 9. Fire Suppression (Sprinkler) System - An approved automatic suppression system shall be provided as <br /> required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett Municipal Code. The system <br /> must include a mechanical water gong bell. <br /> Plans for any such system shall be submitted to the Engineering & Public Services Department for <br /> examination and approval. Such plans shall include plans for the underground mains that will supply <br /> the sprinkler system. <br /> The type of sprinkler to be installed will be determined by the Building Official. It may be an NFPA 13, <br /> NFPA 13R, or NFPA 13D system depending upon several factors. Sprinkler installation shall not begin <br /> without an approved and stamped set of plans from the Engineering&Public Services Department. The <br /> Fire Department will also review the plans and shall field inspect the installation based only on <br /> approved plans that must be on site. Changes to plans must be approved by both the Engineering & <br /> Public Services and Fire Departments. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 for <br /> private fire mains. (Below-ground piping must be installed by Washington State Patrol Licensed <br /> Underground Sprinkler line certified "U" installers. For further information, contact the State Fire <br /> Marshal's Office at(360) 596-3900 or contact the Everett Fire Department at(425) 257-8124.) All such <br /> tests shall be witnessed by a Fire Department inspector. Call (425) 257-8124 or (425) 257-8120 to <br /> make an appointment for inspection. <br /> Contractors' materials and test certificates shall be submitted to the Everett Fire Department prior to <br /> issuance of any Certificates of Occupancy. Call (425)257-8124 for more information. <br /> 10. All fire alarm control panels (FACP) and sprinkler valves shall be in heated rooms or closets with <br /> standard man door access. Locations shall be approved by the Fire Code Official (NFPA 13 8.16.4.1.3). <br /> 11. The location of Fire Department connections (FDC) and post indicator valves (PIV) shall be determined <br /> by the Fire Code Official. If immediate outside man door access is available to the sprinkler valves <br /> (risers), a PIV will not be required. (On building OK). <br /> 12. A building footprint and lot layout for this project shall be provided to the Fire Marshal's Office on <br /> CD/DVD. <br />
The URL can be used to link to this page
Your browser does not support the video tag.