Laserfiche WebLink
uc) i Ver-f ori'Sl vd <br /> C F O DESIGN FIELD REPORT <br /> 1of2 <br /> Pro ect Name: Everett River Front-Simpson Report: 040 <br /> GeoDesign#: Poi •on-127-03 Date: 05/12/2017 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> PW1505-005 <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) Weather:Cloudy,50's <br /> Ron Bowen(Polygon) Eddy Stevens(Polygon) Arrival/Departure: 1400/1530 <br /> Distribution: <br /> Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> Paul McKee(City of Everett) Dave Foster(City of Everett) Prepared By: Ben Weinberg <br /> Attachments: m Site Plan(s) ❑ Density Test Summary Signature: <br /> Installation Records J Other Reviewed By: g <br /> PURPOSE of VISIT:GeoDesign representative,Ben Weinberg,was on-site part time at the request of Craig with DDS to <br /> observe the foundation subgrade for Lot 235. <br /> SUMM, •f OBSERVATIONS: <br /> Lot 235: <br /> o•ay, GeoDesign noted that DDS had completed excavation of the footing and crawl space area for Lot 235. GeoDeslgn <br /> noted that the exposed foundation subgrade consisted of a brown to gray-brown silty SAND(f-m)with gravel(f-c). For the <br /> west 1/4 of the lot area,penetration depths using a 1/2 inch diameter soil probe were less than 2 inches. For the east 3/4 of <br /> the lot area, penetration depths encountered ranged from 6 inches to 1.5 feet.GeoDesign recommended that the east 3/4's <br /> of the lot area be over-excavated down to firm and unyielding material and brought back to bottom of footing elevation with <br /> structural fill. <br /> The client and contractor were notified of our observations prior to our departure from the site. <br /> A summary of our observations can be found in the attached Figure 1 and Photo Log. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnkal engineering or environmental services.We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project Irrespective of the presence of our representative,our wore does not include supervision or direction or the contractor,the contractors employees <br /> or aegpents.Our firm is not responsible for site safety.This field reportIs a DRAFT representation ofour fifld observations,tasting,and.pteliminaryr recommendations.'1be report can only be conskiered <br /> Real upon review of the Gcorksign protea manager,as indicated by Initials in the"Reviewed By"section. <br /> 10700 Meridian Avenue North,Suite 402 I Seattle,WA 98133 1206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98402 1253.203.0095 <br />