Laserfiche WebLink
, Simple Heating System Size: Waw:triiton State <br /> This heating system sizing calculator is based blit the Prescriptive Requirements of the 2012 Washington bf6f6 Energy Code(WSEC)and ACCA Manuals <br /> J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. <br /> The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at <br /> (360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Plan 1775 <br /> i <br /> Heating System Type: O All Other Systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word'Instructions". <br /> Design Temperature <br /> Instructionsij - - ------------------------- Design Temperature Difference(AT) 49 <br /> In Everett Paine AFB w' AT.Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) ; ,_�;1„775,1 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.5 15,088 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> 0.30 H 285,.. ,„„ 85.50 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 _ _. --- <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions <br /> R�9 ' 0.026 . 770. . 20.02 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions ._. <br /> . R-38 Vented ° 0.027 -, - <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions R-21 Intermediate 0.056 2,,000 . 112.00 <br /> lik <br /> FloorsU-Factor X Area UA <br /> Instructions 30 Y y -f <br /> ..-.�_.____-_ --..-._ .- 0.029 4.95'' 14.36 <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions iii No Below Grade Walls inithis project. ___________W_ --- <br /> Slab Below Grade(see Figure 1) F-Factor X Length UA <br /> Instructions ° ,t , No selection --- <br /> Select conditioning I. <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> Instructions1r b 0.540 116 ., 62.64 <br /> R 10 Perimeter - <br /> Location of Ducts <br /> Instructions <br /> Duct Leakage Coefficient <br /> No Ducts .- . <br /> 1.00 <br /> Sum of UA 294.52 <br /> Envelope Heat Load 14,431 Btu/Hour <br /> Figure 1. Sum of UA XAT <br /> Air Leakage Heat Load 7,984 Btu/Hour <br /> -.. VolumeX 0.6 XAT X.018 <br /> Above Grade Building Design Heat Load 22,416 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> .,_�-''' Building and Duct Heat Load 22,416 Btu/Hour <br /> "T`c''X0 Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 31,382 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/01/13).+'1 <br />