Simple Heating System Size: W. igton State <br /> " This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA Manuals <br /> Sand S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. <br /> The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at <br /> (360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Plan 2407 <br /> i <br /> Heating System Type: OO All Other Systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Instructions "_._--- -- -- "--"� —` - --- <br /> - � Design Temperature Difference(AT) 49 <br /> Everett Paine AFB pT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 2,407', <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.5 20,460 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> 0.30 448. 134.40 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 --- <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions 0.026 , 1,120 29.12 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions R-38 vented 0.027 <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions -- .. ._. <br /> R-21 Intermediate Ir. 0.056 2,700 151.20 <br /> Floors U-Factor X Area UA <br /> Instructions <br /> R-so 0.029 _590..., • 17.11 <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions ' 500: <br /> No Below Grade Walls in this project. ,.,j <br /> Slab Below Grade(see Figure 1) F-Factor X Length UA <br /> Instructions <br /> 'Select conditioning "' No selection <br /> �— —�` �` <br /> Slab on Grade(see Figure t) F-Factor X Length UA <br /> Instructions -- t, 0.540 136 73.44 <br /> R 10 Perimeter 7. <br /> Location of Ducts <br /> Instructions <br /> Duct Leakage Coefficient <br /> No Ducts --- -- ' 1.00 <br /> Sum of UA 405.27 <br /> Envelope Heat Load 19,858 Btu/Hour <br /> Figure 1. Sum ofuAXAT <br /> Air Leakage Heat Load 10,827 Btu/Hour <br /> VolumeX 0.6 X AT X.016 <br /> Above Grade Building Design Heat Load 30,685 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 30,685 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 —,, <br /> Ducts in conditioned space:Sum of Building Heat Loss X i f <br /> Maximum Heat Equipment Output 42,960 Btu/Hour f//7 J� <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> ' / �./ , C,/ <br /> Building and Duct Heat Loss X 1.25 for Heat Pump ,`w( <br /> (07/01/13) <br />