Laserfiche WebLink
Simple Heating System Size: Wa--gton State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA Manuals <br /> J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. <br /> The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> ,Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at <br /> (360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Plan 1775 <br /> L <br /> t <br /> Heating System Type: O All Other systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Instructions <br /> - Design Temperature Difference(AT) 49 <br /> Everett Paine AFB AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) , 1,,775,; <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) .,,_._,;.,8.5. 15,088 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> 0.30 ,, 285, ,,,,; 85.50 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 - -- <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions a9 0.026 770, 20.02 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions R-38 Vented R 0.027 <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions R-2.1 Intermediate 0.056 , ,,,2,000 ,_ . 112.00 <br /> Floors U-Factor X Area UA <br /> Instructions P "' - "' <br /> R 30 Cr0.029 4,95 14.36 <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions —" - 800; <br /> lioii No Befoww Grade Walls in this project. <br /> Slab Below Grade(see Figure 11 F-Factor X Length UA <br /> InstructionsNo selection <br /> ii Select conditioning <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> Instructions <br /> 0.540 ..„,..116 62.64 <br /> toR-10 Perimeter 7 <br /> Location of Ducts <br /> Instructions _ ---- — — Duct Leakage Coefficient <br /> No Ducts � <br /> tti1.00 <br /> Sum of UA 294.52 <br /> Envelope Heat Load 14,431 Btu/Hour <br /> Figure 1. Sum of UAXAT <br /> Air Leakage Heat Load 7,984 Btu/Hour <br /> VolumeX 0.6X11TX.018 <br /> Above Grade Building Design Heat Load 22,416 Btu/Hour <br /> ' *z Air Leakage+Envelope Heat Loss <br /> '"15,11 <br /> Building and Duct Heat Load 22,416 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 _ <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 31,382 Btu I Hour r <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/ ) <br />