My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7911 20TH AVE SE 2018-03-14
>
Address Records
>
20TH AVE SE
>
7911
>
7911 20TH AVE SE 2018-03-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/14/2018 11:18:26 AM
Creation date
3/14/2018 8:39:37 AM
Metadata
Fields
Template:
Address Document
Street Name
20TH AVE SE
Street Number
7911
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> Simple Heating System Size: W..gton State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA Manuals <br /> J'and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. <br /> The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at <br /> (360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Plan 2407 .. ,. <br /> ad <br /> Heating System Type: OO All Other Systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> _ <br /> Instructions _....-_ ., ___. _..-. <br /> LL~ r' Design Temperature Difference(AT) 49 <br /> Everett Paine AFB R <br /> AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 2,407c <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.S 20,460 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> 0.30 , 448y. ,,; 134.40 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 --- <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions " 0.026 1,,120 ,, 29.12 <br /> R49 —`--- T1`..� - <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions <br /> R-38 Vented i.� 0.027 <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions R-21 Intermediate R 0.056 2,700 151.20 <br /> Floors U-Factor X Area UA <br /> Instructions .. ,.. <br /> "o „ 0.029 590.. 17.11 <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions -- — __ 500: <br /> No Below Grade Walls in this project. __._�__ ` V. <br /> Slab Below Grade(see Figure 1) F-Factor X Length UA <br /> Instructions __ — No selection <br /> Select conditioning . <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> Instructions ���YYqrr J l 0.540 136 73.44 <br /> R-10 Perimeter - <br /> — <br /> Location of Ducts <br /> Instructions -- --- <br /> __._ _.. _..._- ..._ . _..._._. _ Duct Leakage Coefficient <br /> No Ducts T` <br /> 1.00 <br /> Sum of UA 405.27 <br /> Envelope Heat Load 19,858 Btu/Hour <br /> Figure 1. Sum ofuAXAT <br /> _` Air Leakage Heat Load 10,827 Btu/Hour <br /> VolumeX 0.6XATX.018 <br /> Above Grade Building Design Heat Load 30,685 Btu/Hour <br /> ` Air Leakage+Envelope Heat Loss <br /> _ Building and Duct Heat Load 30,685 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 _ <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> 7'" ---- <br /> Maximum Heat Equipment Output 42,960 Btu/Hour ;' j„,:i • <br /> V <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace I <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.