4416 29TH AVE SE 2018-03-14
>
Address Records
>
29TH AVE SE
>
4416
>
4416 29TH AVE SE 2018-03-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/14/2018 12:05:23 PM
Creation date
3/14/2018 12:05:16 PM
Metadata
Fields
Template:
Address Document
Street Name
29TH AVE SE
Street Number
4416
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LHfly 260111 - \6-c e t <br /> G EO DESIGN FIELD REPO <br /> :121.1) <br /> Project Name: Everett River Front-Simpson Report: 031 <br /> GeoDesign#: Poly on-127-03 Date: 04/27/2017 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> PW 1505-005 <br /> M 1, �..p <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) Weather:Clear, 50's <br /> Ron Bowen(Polygon) Eddy Stevens(Polygon) Arrival/Departure: 1415/1530 <br /> Distribution: -- -- <br /> Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> Paul McKee(City of Everett) Dave Foster(City of Everett) Prepared By: Ben Weinberg <br /> m Site Plan(s) m Density Test Summary Signature: T✓ <br /> Attachments: _ — -- <br /> Installation Records 0 Other Reviewed By: ilect <br /> PURPOSE of VISIT: GeoDesign representative, Ben Weinberg,was on-site part time at the request of Craig with DDS to <br /> observe the foundation subgrade for Lots 211 and 212. <br /> SUMMARY of OBSERVATIONS: <br /> Lot 211: <br /> Upon arrival, GeoDesign noted that the foundation excavation subcontractor had completed excavation of the footing and <br /> crawl space area for Lot 211. GeoDesign noted that the exposed foundation subgrade consisted of a brown, brown-gray, <br /> and gray silty SAND with gravel which could generally be probed less than 2 inches using a 1/2 inch diameter soil probe. <br /> Prior to our arrival on-site, Craig with DDS identified loose and saturated material that would clearly need to be removed <br /> along the west 2/3 of the lot area;the west 2/3 of the lot area was over-excavated by approximately 1.0 to 1.5 feet. It is <br /> GeoDesign's understanding that the lot area will be brought back to plan grade with a 2 inch clean crushed railroad ballast <br /> material compacted into a firm and unyielding mass. <br /> Relative compaction of the footing subgrade material was tested using a Troxler Moisture-Density gauge; in-place density <br /> tests indicated that exposed foundation subgrade material had been compacted to greater than 95%of its maximum dry <br /> density as determined by a Modified Proctor analysis. <br /> Lot 212: <br /> Upon arrival, GeoDesign noted that the foundation excavation subcontractor had completed excavation of the footing and <br /> crawl space area for Lot 212. GeoDesign noted that the exposed foundation subgrade consisted of a brown, brown-gray, <br /> and gray silty SAND with gravel which could generally be probed less than 2 inches using a 1/2 inch diameter soil probe. <br /> Prior to our arrival on-site, Craig with DDS identified loose and saturated material that would clearly need to be removed <br /> along the west 2/3 of the lot area;the west 2/3 of the lot area was over-excavated by approximately 0.5 to 1.0 feet. It is <br /> GeoDesign's understanding that the lot area will be brought back to plan grade with a 2 inch clean crushed railroad ballast <br /> material compacted into a firm and unyielding mass. <br /> Relative compaction of the footing subgrade material was tested using a Troxler Moisture-Density gauge; in-place density <br /> tests indicated that exposed foundation subgrade material had been compacted to greater than 95%of its maximum dry <br /> density as determined by a Modified Proctor analysis. <br /> A summary of our observations and density tests taken today can be found in the attached Figure 1 and Nuclear Density <br /> Gauge Data. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services.We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project irrespective of the presence of our representative.Our work does not include supervision or direction of the contractor,the contractor's employees <br /> or agents.Our firm Is not responsible for site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations.The report can only be considered <br /> final upon review of the GeoDesign project manager,as indicated by initials in the"Reviewed By"section. <br /> 10700 Meridian Avenue North,Suite 402 I Seattle,WA 98133 I 206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98402 I 253.203.0095 <br />