Laserfiche WebLink
4'11° OTTOtOSENAU& ASSOCIATES, INC. <br /> REINFORCING STEEL INSPECTION FIELD REPORT <br /> Job Number: 16-0175 Report Number: 351106 Permit Number: PW1505-005 <br /> Project: Riverfront Simpson Client: Polygon Northwest <br /> Address: 41st Street and go towards the river Everett,WA Address: 11624 SE 5th St Bellevue,WA <br /> Date: 5/24/17 Inspector. Brian R.Robertson WABO SI01181 ICC 0887908- <br /> 49 <br /> Description <br /> Grade: 60 Manufacturer: Nucor <br /> Type of Bar: ®A-615 0 A-706 0 N/A SDQ Steel: 0 Yes ®No <br /> Structural Elements I Location I Grid Lines <br /> On site as requested by the Polygon to inspect reinforcing steel in the Lots 212, 226, 236, and 237 footing walls, <br /> HDU's straps, and interior footings. Inspection of lots 224, 225, and 235 footing reinforcing,and electrical UFER <br /> grounding bars. Work conforms to the City of Everett approved pans and the current IRC Code. <br /> Conforms X Does Not Conform <br /> Is this a re-inspection? 0 Yes ®No Start Time: p.30am Finish Time: 11:30em <br /> Original inspection <br /> date: First inspection by: <br /> Inspected by: -i.— ;+ •.-'`f `'�' <br /> ~ Reviewed by: <br /> This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau&Associates,Inc. Reproduction of this report, <br /> except in full,without written permission from our firm is strictly prohibited. <br /> Page of ----;- <br /> 6747 M.L.King Way S.,Seattle,Washington 98118-Phone(206)725-4600 or 1-888-OTTO-4-US-Fax(206)723-2221 <br /> Form No.:INSP-76-03 LT(Rev 03/08) <br />