J <br /> ' <br /> ;ESIGN? y r , <br /> FIELD RE • <br /> vof <br /> 6 <br /> Project Name: Everett River Front-Simpson Report: 036 <br /> GeoDesign#: Polygon-127-03 Date: 05/04/2017 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> PW1505-005 <br /> x .,,. <br /> El <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) Weather: Clear, 60's <br /> Ron Bowen(Polygon) Eddy Stevens(Polygon) Arrival/Departure: 0915/1615 <br /> Distribution: <br /> Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> Paul McKee(City of Everett) Dave Foster(City of Everett) Prepared By: Ben Weinberg <br /> m Site Plan(s) m Density Test Summary Signature: 4:,--" <br /> Attachments: ❑ Installation Records 121 Other Reviewed By: <br /> SUMMARY of OBSERVATIONS(CONTINUED): <br /> Lot 225: <br /> Previously, GeoDesign noted that DDS had over-excavated the Lot 225 area down 1.5 to 3 feet down to material which <br /> could generally be probed less than 4 inches. Today, relative compaction of the exposed soil was tested using a Troxler <br /> Moisture-Density gauge; in-place density tests indicated that the material had been compacted to greater than 95%of its <br /> maximum dry density as determined by a Modified Proctor analysis. <br /> GeoDesign recommended that the over-excavated area be lined with a non-woven geotextile material and backfilled with <br /> structural fill material. GeoDesign noted that DDS began importing 2-inch railroad ballast for use as structural fill for Lot 225 <br /> today. <br /> Craig with DDS stated that the over-excavated areas would be lined with non-woven geotextile and backfilled with a <br /> crushed rock material starting tomorrow. GeoDesign notified the contractor that the over-excavated areas were currently <br /> suitable to place backfill material. <br /> Lot 238: <br /> Previously, GeoDesign noted areas along the west, south,and east sides of Lot 238 which could be probed 6 inches to 1.5 <br /> feet using a 1/2 inch diameter soil probe. Today, GeoDesign noted that DDS had over-excavated Lot 238 down to a <br /> gray-brown to gray silty SAND with gravel which could generally be probed less than 2 inches. Over-excavation depths <br /> ranged from 4 inches to 1.5 feet. Relative compaction of the foundation subgrade was tested using a Troxler <br /> Moisture-Density gauge; in-place density tests indicated that the material had been compacted to greater than 95% of its <br /> maximum dry density as determined by a Modified Proctor analysis. <br /> GeoDesign notified the contractor that the lot area was currently suitable for the placement of backfill material. Craig with <br /> DDS stated that the over-excavated areas would be backfilled with a crushed rock or recycled concrete material at a later <br /> date. <br /> The client and contractor were notified of our observations prior to our departure from the site. <br /> A summary of our observations and density tests can be found in the attached Figure 1, Nuclear Density Gauge Data,and <br /> Photo Log. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services,We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project irrespective of the presence of our representative.Our work does not indude supervision or direction of the contractor,the contractor's employees <br /> or agents. Our firm Is not responsible for site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations,The report can only be considered <br /> final upon review of the GeoDesign project manager,as indicated by initials in the"Reviewed By"section. <br /> 10700 Meridian Avenue North,Suite 402 I Seattle,WA 98133 I 206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98402 I 253.203.0095 <br />
The URL can be used to link to this page
Your browser does not support the video tag.