. . .. . . . . . . . _. . . .- . � _ _ _ _ -___ . . ,.-. . _ \ <br /> --- - - Permit#: B17Q5-010 <br /> .µ_. .__ AB B REVIATI O N S SYM BO LS 1 N D�X O F D RAWI N GS Owne�r�ress: CO UM IA�CASCA�E PLAZA LLC <br /> "� Tenant: PLANEi'FITNESS <br /> �� � ;, � �y � `_� AB ANCHOR BOLT LAM LAMINATED pp' � u <br /> r�`��� ;£ A Date: 5 1 20ll <br /> ` � ��~�� ACOUST ACOUSTICAL LF LINEAR FEET CURRENI" REVISION Praposed Use: COMMERCIAL <br /> ' � �� � �� REVISION DATE NO. SHEET NAME <br /> � ? AFF ABOVE FINISH FLOOR LG LONG, LARGE Description: INTERIOFI REMODEL INCLUDING FINISHES <br /> � �� � ��� � � ARCHITECTURAL NORTH <br /> � ALT ALTERNATE LL LANDLORD &CONST-PLANET FITNESS , i�7� / <br /> R L4.l i� 3 � ;v- �4 � �^� <br /> � -p .�� � ALUM ALUMINUM LLH LONG LEG HORIZONTAL ARCHITECT�JRAL �� � <br /> ' � �, j A P P R O X A P P R O X I M A T E L Y L L V L O N G L E G V E R T I C A L � 4 � s <br /> G005 PRELIMINARY SITE PLAN Reviewed By: ���� ������Date: � � ��d <br /> �� �'� �. ___ ARCH ARCHITECT/ARCHITECTURAL LP LOW POINT GENERAL <br /> � +�� ����� � �'} BD BOARD MAS MASONRY f�Office Set �ob Site Set Firef Planning Set <br /> � � ��z� : <��;�; � '� �- 1 WALL SECTION G001 COVER <br /> BLDG BUILDING MATL MATERIAL <br /> � , �r� �'k 3 � �fi.� BLK BLOCK MAX MAXIMUM A101 G002 ADA DETAILS <br /> � `�_ <br /> F � �f = � �''� �� � � BLKG BLOCKING MECH MECHANICAL - G003 LIFE SAFETY PLAN <br /> t` � �� '��'" � <br /> BM BEAM MED MEDIUM G 0 0 4 U L R A T E D A S S E M B L I E S A R C H I T E C T U R E 105 BROADWAY <br /> £ �� �� � '��� BOS BOTTOM OF STEEL MFR MANUFACTURER 4TH FLooR <br /> � '"� n'�r.��e ��„�. <br /> ��, � ; ; �`� � °'"� ,`'� � �°�,. BRG BEARWG MIN MINIMUM � ARCHITECTURAL PLANNING NASHVILLE,TN 37201 <br /> •� �''�`��'�� ` � ' �f�'�`' BS BOTH SIDES MISC MISCELLANEOUS A101 DEMO PLAN (P)615.244.8170 <br />, �s � ��� T�3^` � ,�.x r , INTERIORS (F)615.244.8141 <br /> BTM BOTTOM MO MASONRY OPENING A102 FLOOR PLAN &DETAILS <br /> r��'' ��e � �, `'•• BTS BUILD TO SUIT MTD MOUNTED � A101 1 ELEVATION GRAPHICS www.mjmarch.com <br /> �f � <br /> A103 REFLECTED CEILING PLAN <br /> � ' � ����� � I. � f� BUR BUILT UP ROOF MTL METAL A104 FLOOR FINISH PLAN <br /> �� �`�� �����,�' r� <br /> » �.���� � ,. � <br /> � ��� , �k�� �, f� CI CAST IRON N NORTH � <br /> �` �� '� � � '_ ' V. ��'�k ; CJ CONTROL JOWT NIC NOT IN CONTRACT A105 EQUIPMENT PLAN <br /> _ . __.__.z � y��� •}z . , ,__.,,..___._._,, CT CERAMIC TILE NO,# NUMBER A401 ENLARGED PLAN &ELEVATIONS <br /> ) F �,� :,- ,,�� �<. ` . <br /> P <br /> ' ` CAB CABWET NTS NOT TO SCALE <br /> - <br /> t ,'F �, • �' ��_ � � � A402 INTERIOR ELEVATIONS <br /> ' _ €,� . � �`'s, CEM CEMENT(ITIOUS) O/A OVERALL I DETAIL TAG A403 ENLARGED PLANS&ELEVATIONS <br /> � L ° '1, CG CORNER GUARD OFD OVERFLOW DRAIN A101 �__J A404 WTERIOR ELEVATIONS <br /> }� ��:��. `'sf; CL CLEAR O/H OVERHEAD <br /> � CL, C L CENTERLINE O/O OUT TO OUT A405 INTERIOR ELEVATIONS <br /> � " � ` CLG CEILING OC ON CENTER � CEILING TAG A501 WALL SECTIONS � , � <br /> �.- <br /> �s.�; � � �� � ���� <br /> �� ; CMU CONCRETE MASONRY UNIT OD OUTSIDE DIAMETER �oo�-o°AFF A502 DETAILS {���;�,`�` � ;.� � }- <br /> '�.. �'� ��� t ������,�. � <br /> _„_�' <br /> � 1 CO CLEAN OUT OPNG OPENING � � <br /> � --_._...�� <br /> A503 DETAILS � ��# � a ��a �` ' 3 <br /> COL COLUMN OPP OPPOSITE � � ��� � . �;: �� ,E ° ; � <br /> I����� �� �� �� � ��� � CONC CONCRETE P PAINT � A504 DETAILS ��� ���„� �,�`""� � � ` <br /> ���� <br /> � MATERIAL FINISH TAG �,.� R � ;� , � � <br /> � �__ �' CONST CONSTRUCTION PC PIECE A601 SCHEDULES <br /> i 3 <br /> � ' � CONT CONTWUOUS PL, P PLATE � <br /> 3 <br /> ; j CONTR CONTRACTOR PLAS PLASTER, PLASTIC This permit review does not cover <br /> A801 EXTERIOR ELEVATIONS � ' � �'� � � =a <br /> � <br /> ~ � �;. CPT CARPET PLYWD PLYWOOD CEILING ELEVATION T�derai ADA, FHH or HUD regulatior�� A901 CAL GREEN � ��,�-"` �; ` � <br /> � , . �----------- <br /> -_-----. CR CARTRAIL,CHAIRRAIL PTD PAWTED 10'-0" �nd standards, including the A902 CAL GREEN ��'� � ���' ��g: ��#� 3� <br /> _ � ` , ;�, � <br /> ; � --=" � � ' _� ; .. <br /> , _:� � ��, ' , CSK COUNTERSUNK QUAN QUANTITY Fair Housing Accessibility Guidelines. STRUCTURAL � �� � �'� �s � '' <br /> ,� XX� <br /> � � ' '' � D DEPTH; DEEP R RADIUS; RISER Compliance with those regulations is'th S101 GENERAL NOTES «����°�����`°»"""����`�'�A > <br /> � : _.._ DBL DOUBLE RD ROOF DRAIN � WINDOW TAG <br /> a � r�sp�nsibility 9f the owner 9fi the b�ildin a �'.,,"u • <br /> . .} DEMO DEMOLITION REINF REWFORCING S201 ROOF FRAMING PLAN <br /> k'� '� DET DETAIL REQD REQUIRED S301 DETAILS <br /> ' ,.��� " `��-, DIA DIAMETER RESIL RESILIENT RM NAME ROOM TAG � S401 TYPICAL METAL STUD DETAILS <br /> �,. <br /> l�t� �''' x`�� ��-��,.:,-� DN DOWN REV REVISION, REVERSE 0 �%�� � �� �u����� S402 TYPICAL METAL STUD DETAILS <br /> °�, <br /> �-��� <br /> , 3,.-- ,__ �. DIM DIMENSION RM ROOM ti MECHANICAL <br /> ' ,_- � _�� ��V1�V�1��3 F�J'� P���'� <br /> , r - ' �� K--" ---� DO DOOR OPENING RO ROUGH OPENING <br /> {� �� ��- ' �"� ��``� � �� DS DOWNSPOUT RQMTS REQUIREMENTS � DOOR TAG M001 SPE�S, SCHEDULES&DETAILS <br /> � •� � �`=fi � � ���, �� � ` DWG DRAWING RTS REHAB TO SUIT M102 HVAC-FLOOR PLAN � <br /> ° _ �, E EAST RTU ROOF TOP UNIT M103 HVAC-ROOF PLAN <br /> r <br /> ~�,,,y _ � �� ,,�"'f T ,�_ EA EACH RWL RAIN WATER LEADER PLUMBING <br /> :�" �:�� _ <br /> ' _ Jf�,� �`i� ° .'�.., ,.,-''' _- • � EB EXPANSION BOLT NISH SYS. SCHED SCHEDULE REVISIO�� ���u����'�MF�y� �CE O� � <br /> �-�:� P001 SPECS, SCHEDULES &DETAILS <br /> EIFS EXT INSULATION FI SD SELF DEVELOP ��� <br /> �, ' � ` EJ EXPANSION JOINT SF SQUARE FEET, STOREFRONT <br /> + __,, - � a���z�+a�����a��G issua <br /> �f '�� - EL ELEVATION (FLOOR) SHT SHEET ���L��1NU�2KS,iV�E�H/��V1CAL, rlr2� P100 PLUMBING- DEMO FLOOR PLAN <br /> P101 PLUMBING-UNDERGROUND FLOOR PLAN <br /> ���m�'T �~ ELEV ELEVATION SIM SIMILAR �U�'P�2�SSiCJN,E���Tr�1�A�.�� P102 PLUMBING-FLOOR PLAN <br /> ELEC ELECTRICAL SMS SHEET METAL SCREW p���y�{�(�P��MIYS. <br /> P103 PLUMBING-ROOF PLAN <br /> P E R M I T S E T M J M P ROJ E CT # 16 3 0 6 0 5/04/ 17 EQ EQUAL SPECS SPECIFICATIONS P104 PLUMBING-WASTE RISER <br /> EQUIP EQUIPMENT SQ SQUARE <br /> EM/ EACH WAY SQ FT SQUARE FOOT/FEET P105 PLUMBING-WATER RISER <br /> EWC ELECTRIC WATER COOLER SS SERVICE SINK, STAINLESS STEEL ELECTRICAL <br /> EXIST EXISTING STD STANDARD E101 LIGHTING FLOOR PLAN <br /> EXP EXPOSED, EXPANSION STL STEEL Additi�nal P�rmifis�Are Required E201 POWER FLOOR PLAN <br /> P ROJ E CT D I RE CTO RY EXT EXTERIOR STOR STORAGE <br /> FOF FACE OF FRAMING STRUCT STRUCTURAL FOt'T�IIS Proj�ct T'o Includ�: E301 ELECTRICAL DETAILS <br /> FOM FACE OF MASONRY SUSP SUSPENDED E302 ELECTRICAL DETAILS <br /> C L I E N T A RC H I T E CT FD FLOOR DRAIN T TREAD E401 ELECTRICAL LEGENDS <br /> F/O FACE OF T/B TOP&BOTTOM � �a��'1blT'1� � �pri�kler <br /> FIN FINISH TEL TELEPHONE j� �ech�nicai �� Fire Alarrn E501 ELECTRICAL PANELBOARDS . <br /> FL FLOOR T/O TOP OF ,_ � <br /> PLAN ET F ITN ESS MJ M ARCH ITECTS FDN FOUNDATION To TAKE OVER �� Ef��trical <br /> FS FLOOR SINK TOM TOP OF MASONRY <br /> FT FOOT, FEET TOS TOP OF STEEL <br /> FTG FOOTING TH THICK(NESS) FIf2 d2fGCtI0f1�Cld alaCfi'1 SyStefi1 Upd2t8S <br /> GC GENERAL CONTRACTOR TYP TYPICAL may be required throughout permit area. SPRINKLE� VALV�� AND ��?�111PONEN � <br /> GA GAUGE; GYPSUM ASSOC. UL UNDERWRITERS LABORATORY ���;� ,���������� �����+'���� ���� Contact Ffre Depar�ment at425-257-�120 <br /> GALV GALVANIZED UNO UNLESSNOTED OTHERWISE •�! � ,������^��N �Y�'��� ����JIR�� �OCIci�IfySCOp�. N�U�T �� NIAINTAIN�D AT 40°F � <br /> GEN GENERAL V VOLT �J <br /> GL GLASS/GLAZING:GLUE VCT VINYL COMPOSITION TILE �INI�UNI ���P��ATU�� PEFZ NFPA ' ,� <br /> GWB GYPSUM SOARD VIF VERIFY IN FIELD ���������D ��`���ja�'��; Electrical permit required from Permit Services <br /> 712 4TH AVE. S. H HIGH VERT VERTICAL far n@w work or revision� 425-257-$$1 0 <br /> NASHVILLE, TN 37210 Hs HOSE BIBB W WIDTH;WASTE;WEST;wiRE _ 5'�F�INKL'�� S Y��'�� ���U»�� � �.A l a r m <br /> and detection permit application and drawing� <br /> H C H A N D I C A P P E D W/ W I T H t o b e s u b m r t t e d d i r Qc t ly to Permi t ServiGes, �,r,,� <br /> HDW HARDWARE WC WATER CLOSET <br /> HM HOLLOW METAL WD WOOD '� ' <br /> GRETCHEN BARKER HORIZ HORIZONTAL WT WEIGHT := r_ ' <br /> (615) 244-8170 HP HIGH POINT W/H WATER HEATER ,� � -�r �' <br /> 615 244-8141 HT HEIGHT W/I WITHIN G E N E RAL N OTES �O��� � ����_� r ' <br /> .<.. <br /> ;. <br /> � � HVAC HEAT., VENT., &AIR CONDITIONING W/O WITHOUT Y y,, % <br /> g.barker@mjmarch.COtll ID INSIDE DIAMETER WWF WELDED WIRE FABRIC ;-- �„�`" - -- <br /> INCL INCLUDE(ING) <br /> INSUL INSULATION I. APPLICABLE BUILDING CODES: <br /> 1. CONTRACTOR SHALL REVIEW AND BECOME FAMILIAR WITH PLANET FITNESS <br /> INT WTERIOR, INTERMEDIATE GUIDELINES. CITY OF EVERETT,WA � ` <br /> JT JOINT 2U15 INTERNATIONAL BUILDING CODE WITH WAAMENDMENTS " <br /> 2. CONTRACTOR SHALL COMPLY WITH ALL CODES, ORDINANCES,LAWS, 2U15 INTERNATIONAL ELECTRIC CODE �� <br /> REGULATIONS AND OTHER LEGAL REQUIREMENTS OF AUTHORITIES HAVING 2U15 INTERNATIONAL MECHANICAL CODE WITH WAAMENDMENTS .. `� <br /> JURISDICTION. 2015 UNIFORIVI PLUMBING CODE WITH WAAMENDMENTS <br /> 2015 INTERNATIONAL ENERGY CONSERVATION CODE W ITH WA AMENDMENTS \''��'` - <br /> , � <br /> 3. BIDDING SUBCONTRACTORS SHALL VISIT THE SITE AND REVIEW EXISTING AS- 2U15 INTERNATIONAL FIRE CODE WITH WA AMENDMENTS " ' `�'""� <br /> BUILT CONDITIONS OF THE BUILDING. INCLUDE ALL WORK NECESSARY TO 2U15 WASHINGTON STATE ENERGY CODE <br /> � PROVIDE A COMPLETE AND FULLY FUNCTIONAL SPACE AND AS NEEDED TO MEET 2�15 INTERNATIONAL EXISTING BUILDING CODE P LAN �T <br /> : RE Q U I RE D VE N D O R L I ST D E F E RRE D S U B M ITTALS THE DESIGN INTENT OF THE CONTRACT DOCUMENTS. 2U09 ICC A117.1 <br /> 4. FIELD VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS AND IMMEDIATELY II. OCCUPANCY GROUP: F I T N E S S <br /> NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND PRIOR TO A. PROPOSED: A-3 (ASSEMBLY)WITH NON-SEPARATED MIXED USE <br /> BEGINNING WORK. B (BUSINESS)&S-1 (STORAGE) <br /> 1. FIRE SPRINKLER TENANT IMPROVEMENT SHALL BE SUBMITTED BY G.C. ON SEPARATE 5. IF INCONSISTENCY OCCURS ON THE DRAWINGS,THE HIGHER QUALITY SHALL B• PREVIOUS: A-3 (ASSEMBLY)WITH NON-SEPARATED MIXED USE � <br /> ITEM VENDOR _ PRODUCT NAME ADDRESS WEBSITE PHONE CONTACT EMAIL PERMIT. GOVERN UNLESS DIRECTED OTHERWISE BYTHE ARCHITECT. B(BUSINESS)&S-1 (STORAGE) <br /> ACCESSORIES N�J CHANGE IN OCCUPANCY, SQUARE FOOTAGE OR MEANS OF EGRESS <br /> DEFIBRILLATOR AUTOMATED EXTERNAL DEFIBRILLATOR DEFIBRILLATOR P:(978)561-5000 SUE DITUcci 2. FIRE ALARM TENANT IMPROVEMENT SHALL BE SUBMITTED BY G.C. ON SEPARATE PERMIT. 6.ALL WORK SHOWN/NOTED ON THE DRAWINGS IS NEW WORK UNLESS <br /> BEVERAGE COOLERS �LOCAL PEPSI DISTRIBUTOR SOFT DRINKS/COOLERS pepsico.com P:(781)366-7418 KRISTEN(HALL)RINOWSKI kristen.rinowski@pepsico.com SPECIFICALLY NOTED AS EXISTING.ALL ITEMS INDICATED AS EXISTING SHALL BE III. CONSTRUCTION TYPE: <br /> Au�lo visUAL 3.ANY REQUIRED SEISMIC ENGINEERING DESIGN FOR NEW OR MODIFIED SPRINKLER UNDERSTOOD TO REMAIN AND BE PROTECTED. <br /> SYSTEMS OR GAS PIPING SHALL BE SUBMITTED BY G.C. ON SEPARATE PERMIT. A.V-B,;UNPROTECTED, SPRINKLERED.ASSUMED CONSTRUCTION TYPE BASED ON <br /> PLANET FITNESS N CLUBCOM(PREFERRED) CLUB RADIO clubcom.com P:(412)706-5360 CHRIS TRAY christray@clubcom.com 03SERVABLE CONDITIONS. EXTERIOR CMU WALLS, STEEL COLUMNS, LAMINATED • <br /> TELEVISIONS MYE ENTERTAINMENT CLUB TELEVISIONS myeclubtv.com P:(315)363-3726 STEVE JOANIS sales@adk-cc.com 7.THE TERM"PROVIDE"ON THE DRAWINGS MEANS FURNISH AND INSTALL. WOOD ROOF STRUCTURE, INTERIOR METAL STUD FRAMED PARTITIONS. <br /> TRIANGLE TRUSS ADIRONDACK(PREFERRED) STRUCTURAL TRUSSES FOR CLUB TELEVISIONS adk-cc.com P:(315)363-3726 STEVE JOANIS sales@adk-cc.com 4. EXTERIOR SIGNAGE-THE INSTALLATION OF EXTERIOR SIGNS WILL REQUIRE A SEPERATE <br /> BATHRooM AccEssoRiEs PERMIT AND APPROVAL PROCESS. 8. REPAIR/REPLACE ANY EQUIPMENT OR FINISHES DAMAGED DURING <br /> "'*ALL NEW CONSTRUCTION TO COMPLY WITH TYPE V-B CONSTRUCTION. <br /> HAND DRYER/BATHROOM NEWTON DISTRIBUTING COMPANY CUSTOM PF DESIGNED DRYERS newtondistributing.com P:(877)837-7745 DANA D'AGOSTINO dana@newtondistributing.com DEMOLITION AND INSTALLATION OF THE WORK; INCLUDING MECHANICAL, <br /> FIXTURES/PARTITIONS ELECTRICAL AND FIRE PROTECTION WORK. B. FIRE RESISTANCE REQUIREMENTS (TABLE 601) <br /> CHANGING ROOM STATIONS HOME DECORATORS MELANIE STOOL homedecorators.com 1. STRUCTURAL FRAME: REQUIRED=0 HOUR, PROVIDED=0 HOUR <br />� BATHROOM PARTITIONS MATERIAL HANDLING SALES,INC BATHROOM PARTITIONS mathand.com P:(800)458-6870 DON HATHORN dhathom@mathand.com 9. PATCH SPRAYED-ON FIREPROOFING(IF ANY)WHERE DAMAGED BY 2. EXTERIOR BEARING WALLS: REQUIRED=0 HOUR, PROVIDED =0 HOUR <br /> COMPUTERS DEMOLITION AND INSTALLATION OF NEW CONSTRUCTION. 3. INTERIOR BEARING WALLS: REQUIRED=0 HOUR, PROVIDED=0 HOUR <br /> COMPUTERS&ACCESSORIES ABC(DATATRACK) POS SYSTEM ab�nancial.com pfsupport@abcfinancial.com 4. EXTERIOR NON-BEARING WALLS: REQUIRED=0 HOUR, PROVIDED=0 HOUR <br /> ENERGY SAVINGS REBATES 10. DO NOT'SCALE DRAWINGS, IF DIMENSIONS ARE IN QUESTION, CONTACT THE 5. INTERIOR NON-BEARING WALLS: REQUIRED=0 HOUR, PROVIDED =0 HOUR <br /> SAVE ENERGY SAVE ENERGY SYSTEMS ENERGY SAVINGS saveenergysystems.com P:(617)564-4442 PAUL LASKOW plaskow@saveenergysystems.com ARCHITECT FOR CLARIFICATION. 6. FLOOR CONSTRUCTION: REQUIRED=0 HOUR, PROVIDED=0 HOUR <br /> REBATES/INCENTIVES MANAGED ENERGY SYSTEMS ENERGY SAVINGS&REBATES energymes.com P:(913)333-3713 LEAH MULLEN leah@energymes.com VI C I N ITY MAP 7. ROOF CONSTRUCTION: REQUIRED=0 HOUR, PROVIDED=0 HOUR <br /> EQUIPMENT 11. DETAILS AND NOTES ON DRAW ING SHALL BE CONSIDERED TYPICAL AND <br /> FITNESS CLUB WORKOUT PF EQUIPMENT COMPANY(MANDATORY) LIFE FITNESS/CYBEX PF CORPORATE P:(603)750-0001 x301 (ADAM) ADAM RAITT adam.raitt@pfhq.com APPLY TO ALL SIMILAR CONDITIONS UNLESS NOTED OTHERW ISE. <br /> EQUIPMENT __ - - P:(603)750-0001 x302(CHRISTINA) CHRISTINA NYE christina.nye@pfhq.com r�;,�s.;,� � S <a �,, � FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE <br /> METAL PAPER TOWEL<RODS PLANET FITNESS CORPORATE METAL RODS TO GO ON TOP OF TRASH PF CORPORATE P:(603)750-0001 x302 CHRISTINA NYE christina.nye@pfhq.com °, � ° �� - SEPARATIOIV <br /> �� ""~--..,� 12. PLAN PARTITION DIMENSIONS ARE NOMINAL FINISH SURFACE TO FINISH DISTANCE TABLE 602 <br /> E�� € �� � �' � r���.��s� <br /> BRANDED BLACK CARD DREAMSEAT BRANDED BLACK CARD FURNITURE dreamseat.com P:(631)656-1066 RYAN HEENAN rheenan@dreamseat.com „"� � �� � x ,.� ;> "� � SURFACE UNLESS NOTED OTHERWISE. � �' <br /> FURNITURE _. ;� ��� �� � �� �' 7a�,.s�y, �. <br /> � ��� '' "��� '` I � LESS THAN 5'-2 HOUR <br /> -_-MASSAGE BEDS/LOUNGES ITYDROMASSAGE(MANDATORY) JTL ENTERPRISES 15395 ROOSEVELT BLVD. P:(727)536-5566 PAUL LUNTER plunter@hydromassage.com ';?h s�'� �� `�"�'�`� r 13. CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL GREATER THAN 5' LESS THAN 10'- 1 HOUR <br /> CLEARWATER,F�33�so �`�,°�'��`a,,��r i GREATER OR EQUAL TO 10 -NOT REQUIRED P LAN �T <br /> SUBCONTRACTORS AND INSPECTIONS. CONTRACTOR SHALL ALSO COORDINATE <br /> MASSAGE CHAIRS SMARTE CARTE(MANDATORY) MASSAGE CHAIRS 4455 WHITE BEAR PKWY. P:(800)838-1176 BARBARA SLATER slaterb@smartecarte.com � WITH THE OWNER FOR ANY OUT-OF-CONTRACT WORK. <br /> ST.PAUL,MN 55110 � ; *ALL EXISTING EXTERIOR WALLS HAVE FIRE SEPARATION DISTANCE GREATER <br /> TANNING BEDS&BOQTHS JK NORTH AMERICA MANDATORY BED:ERGOLINE PASSION 40/3 suner oline.com P: 870 273-9198 BRIGITTE BRIGITfE KRATZ bri itte.kratz us=k- rou .net 7a�hscs� �5��,s�-sr� 'Sth,s?5� �'aati�st 7E�;5xhst�E THAN 10'-NO FIRE RATING RE UIRED. F I TN E S S <br /> � > 9 � � � > 9 °� 1 9 P t � �� r� 14. SEAL ALL PENETRATIONS WITH APPROPRIATE SMOKE STOPPING MATERIALS, Q <br /> BOOTH:SUNRISE 480 P:(870)336-1591 (LAURIE) LAURIE JOHNSON laurie.johnson@jkamerica.com ° � � �' ( �' <br /> TANNING BEDS&BOOTHS HEARTLAND TANNING(MANDATORY) BED:OVATION 134 heartlandtan.com P:(916)804-7055(MARTY) MARTY SLOAN martys@heartlandtan.com a � � � �� � PROVIDE FIRE STOPPING FOR ALL PENETRATIONS IN FLOORS, CEILINGS, CHASES MAXIMUM AREA OF EXTERIOR WALL OPENINGS TABLE 704.8 <br /> BOOTH:SUNDAZZLER 160W P: 800 230-9422 T <br /> FANS � � r.; .�.�` � -..� �-a���r � • farK-ur� � AND FIRE RATED WALLS. � ) <br /> � � � �,� E , � a a � UNLIMITED WITH SEPARATION GREATER THAN 30' <br /> �' % � � � E f'1 x ,''" ' � � :, 3,� ._ 15. COORDINATE W ITH OWNER AND LANDLORD FOR INSTRUCTIONS ON GREATER THAN 25 -700% GREATER THAN 10'- 15% � <br /> CEILING FANS BIG ASS FAN COMPANY(PREFERRED) FANS 2425 MERCHANT ST. P:(859)967-1687 PETE NUCKOLS pete.nuckols@bigasssolutions.com < ,- � �,,,�, GREATER THAN 20 -45/o GREATER THAN 5'- 10% <br /> LEXINGTON,_KY4o5��-- - � �� ' - � $��?��_,.� 4�`` m � '� DELIVERIES,TRASH REMOVAL, STAGING, PARKING AND OTHER SIfv�ILAR GREATER THAN 15'-25% LESS THAN 5'-0% <br /> CEILING FANS KELLY FANS(PREFERRED) FANS 1612 HUTTON DR.STE.140 4frontes.com P:(972)236-2446 DAN I.INDER dan.linder@entrematic.com , � • � G��� .�,:; r . �' CONSTRUCTION RELATED ACTIVITIES. PROVIDE 48 HOURS NOTICE'FOR ANY 7621 EVERCREEN WAY <br /> ._. �.. � � a t�r�� � � � �- <br /> . CARROLLTON,TX 75008 � € ,�� e, , �.� ACTIVITIES THAT W ILL DISRUPT ADJACENT EXISTING TENANTS. IV. FIRE PROTECTION SYSTEM: <br /> , � ;, �� �� .�. EVERETT, WA 98203 . <br /> FINISHEs �.: � .-.m,,y �, z A. EXISTING BUILDING IS FULLY SPRINKLERED. SEE SPRINKLER DESIGN INTNENT <br /> METALLIC FRP WAINSCOT MARLITE(PREFERRED) CROSSHATCH W/EITHER SQUARE 5,SMOOTH,RIB,OR DOME TEXTURE marlite.com P:(603)924-9128 JAMIE McEDWARD jmcedward@marlite.com t,`'�•. ..�F ..' � ;„-,��`� `�' 16. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING PERMITS DF2AW INGS FOR MODIFICATION TO EXISTING SYSTEM. <br /> M:(330)260-7627 w,�3�b�;��f4 }�,- r ' ' /' ';4 � �, FOR FIRE PROTECTION, FIRE ALARM, PLUMBING, SIGNAGE (WHERE APPLICABLE) B. EXISTING FIRE ALARM SYSTEM, MONITORING AND NOTIFICATION. <br /> METALLIC FRP WAINSCOT IMPACT SPECIALTIES(PREFERRED) WAINSCOT impactspeciafties.com P:(908)849-3073 MICHELLE BUEHLER mbuehler@impactspecialties.com ti': ��,, SITE �, � 4�;-t MECHANICAL&ELECTRICAL SYSTEMS PRIOR TO INSTALLATION OF THOSE C. SPRINKLER AND FIRE ALARM SYSTEM MODIFICATIONS ARE DEFERRED � <br /> M:(570)419-0529 ° �7t1z-�t.�c-�, a� � <br /> .� ' l � �; : SYSTEMS UNLESS NOTED OTHERWISE. SUBMITTAL ITEMS BY CONTRACTOR. CONTRACTOR SHALL SUBMIT SIGNED AND <br /> FRP IN TANNING ROOMS MARLITE(PREFERRED) BRANDED FRP marlite.com P:(603)924-9128 JAMIE McEDWARD jmcedward@marlite.com ���' � f�� � w `�,a�`'� c o�aa ` <br /> �- SEALED ENGINEERED DRAW WGS AND CALCULATIONS FOR MODIFICATIONS TO <br /> . M:(330)260-7627 ,�,,� � : ��, .,� � � s� <br /> ,�r `�.,, s,r � ,��, � s;rf ,.. 17. ELECTRICAL PANELS, FIRE EXTINGUISHER CABINETS, ETC. IN STUD WALLS SPRINKLER AND ALARM SYSTEMS TO ARCHITECT/ENGINEER OF RECORD FOR <br /> FRP IN TANNING,ROOMS IMPACT SPECIALTIES(PREFERRED) ACROVYN TEXTURE COLLECTION,MISSION WHITE impactspecialties.com P:(908)849-3073 MICHELLE BUEHLER mbuehler@impactspecialties.com F.`` ,.;.� ,� � � '�"' SHALL BE BACKED WITH DRYWALL AS REQUIRED TO MAINTAIN WALL RATING, REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO REVIEWING AUTHORITY. <br /> M:(570)419-0529 r - -' °`'�ti4 -,-�' � �' CONTRACTOR TO VERIFY WALL THICKNESSES REQUIRED FOR ALL ELECTRICAL <br /> PAINT SHERWIN WILLIAMS(MANDATORY) CUSTOM PF COLORS sherwin-wiliiams.com P:(603)742-6963 SHERWIN WILLIAMS � '-- � % `' PERMIT SET <br /> • WALLPAPER NORTHEAST COLOR INC.(MANDATORY CUSTOM PF COLORS ( ) pf@northeastcolor.com f , :-; �y ` , ! `' ` PANELS, FIRE EXTINGUISHER CABINETS, ETC. VII. OCCUPANT LOAD <br /> ) pfsignshop.com/pf/xcart P: 603 436-8210 BILL FORTE r ` ,:';�.�` „ <br /> � , t Raita,���� ' � •�ECTION 1004-GENERAL MEANS OF EGRESS(TABLE 1004.1.2) <br /> bill@northeastcoloccom � �''� > .� b:. <br /> �- ' d�°z 18. PROVIDE DOUBLE STUDS&BLOCKING AS REQUIRED TO SUPPORT EXERCISE AREAS=50 SF GROSS/OCC. (18,307 SF)=366 <br /> TILE CREATIVE MATERIALS CORP. INTERIOR TILE � creativematerialscorp.com P:(800)207-2967 x7538 DONALD KELLISH pftile@creativematerialscorp.com �„___ 1� <br /> TILE FITZGERALD TILE INTERIOR TILE fitzgeraldtile.com P:(800)234-8453 CONNIE FITZGERALD conniefitzgerald@fitzgeraldtile.com --�� ��' � EQUIPMENT AND/OR MISCELLANEOUS ITEMS,-TYP. CASEWORK, GRAB BARS, �OCKERS=50 SF GROSS/OCC. (3,785 SF)=76 0 5/04/ � � <br /> �-� `"" ���r;�,��,,,�, s� ETC. BUSINESS(RECEPTION, SPA&OFFICE AREAS)= 100 SF GROSS/OCC. (4,782SF)=48 ' <br /> RUBBER FLOORING ADIRONDACK RUBBER PRODUCTS BLACK W/YELLOW&PURPLE FLECK adk-cacom P:(315)363-3726 STEVE JOANIS sales@adk-cc,com � � <br /> %� -'�� �TORAGE=300 SF GROSS/OCC. (1,468 SF)=5 MJM # 16306 � <br /> (MANDATORY) M:(315)335-3544 �i� � ; `' <br /> _; ,. . . <br /> 19. FIREPROOFING, SEALANTS&DAMPERS MAY NOT BE SHOWN ON SOME <br /> RUBBER FLOORING ECORE INTERNATIONAL(MANDATORY) BLACK W/YELLOW&PURPLE FLECK 715 FOUNTAIN AVE. everlastflooring.com P:(515)450-2144 MATT KOCH matt.koch@ecoreinti.com �' ,,����u;tr,Qa�art`' .,.� .,,.� �-�-- DETAILS FOR CLARITY. HOW EVER,ALL ASSEMBLIES MUST BE INSTALLED AS 28,342 TOTAL SF/495 OCCUPANTS <br /> LANCASTER,PA 17601 RANDY KISER gratefulhomeservices@yahoo.com � <br /> FURNISHINGS KEY P LAN REQUIRED TO MAINTAIN RATING INDICATED ON PLANS.ALL PENETRATION <br /> LOCKER ROOM BENCHES WABASH VALLEY YELLOW,GREEN,PURPLE&BLACK FLAT TOP wabashvalley.com P:(800)253-8619 x546 LESLEY BROUYETTE Ibrouyette@wabashvaliey.com SEALANTS OR ASSEMBLIES SHALL BE UL LISTED (OR EQUIVALENT)FOR VIII. EXi1'CAPACITY NO. DESCRIPTION DATE <br /> INSTALLATION WITHIN THE RATED WALL ASSEMBLY NOTED ON THE PLANS. THE A. MINIMUM NUMBER OF EXITS(SECTION 1021) <br /> LOCKER ROOM BENCHES HOLLMAN,INC. BENCHES hollman.com P:(972)s15-4066 TINA SMITH tinas@hollman.com CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM "I"OTAL OCCUPANT LOAD =495 OCCUPANTS=2 EXITS, MIN. <br /> ACCESSIBLE BENCHES LOCAL/CUSTOM BUILD CHANGING&LOCKER ROOMS <br /> -��*- r f � i THE OWNER'S REPRESENTATIVE BEFORE CONTtNUING CONSTRUCTION B. NUMBER OF EXITS PROVIDED: 5 <br /> TRASH BARRELS&ACCESSORIES WABASH VALLEY YELLOW,GREEN&PURPLE TRASH CANS wabashvalley.com P:(800)253-8619 x546 LESLEY BROUYETi'E Ibrouyette@wabashvalley.com •, �� :�� � �` ` <br /> ; �' �``"d� ` ' � -- _„_ �:_ � C. EACH EXIT MUST ACCOMMODATE GREATER THAN 50%OF THE TOTAL OCCUPANT <br /> STAINLESS STEEL ROUND TOP STACK CHAIR DEPOT STAINLESS STEEL ROUND TOP TABLE stackchairdepot.com P:(866)586-9975 MARILYN marilyn@danielpaulchairs.com � � E ��-: 20. WHERE WALL RATWGS APPEAR ON BOTH SIDES OF DOORS AND OR LOAD SO THAT LOSS OF ANY ONE EXIT DOES NOT REDUCE AVAILABLE CAPACITY TO <br /> TABLE r z _ -� €_.' !�1 '. <br /> STAINLESS STEEL CHAIRS STACK CHAIR DEPOT ALUMINUM ARM CHAIRS stackchairdepot.com P:(866)586-9975 MARILYN marilyn@danieipaulchairs.com �' ' "' ' ' ' '�'-� `- � CONTINUE ABOVE THE FRAME TO THE LESS THAN 50%OF OCCUPANTS. - - <br /> WINDOWS THE WALL TYPE SHOWN SHALL <br /> � HAND CHAIRS HAND SHAPED CHAIRS HAND SHAPED CHAIRS handshapedchairs.com P:(815)980-4766 SHAWN BARBAGALLO � . � �" , , {' �-- � CEILING OR STRUCTURE AS APPLICABLE. <br /> r,, WORKOUT MIRRORS THE MIRROR COMPANY WORKOUT MIRRORS themirrorcompany.com P:(800)473-0619 DAVE MANESS dave@themirrorcompany.com ��°�' � F ` _ "=' �. EXIT CAPACITY-CALCULATIONS (1005.3.2) <br /> � '� 21. THE HWGE SIDE OF ALL INTERIOR DOOR FRAMES SHALL BE PLACED 4" FROM DOORS,0.20"PER PERSON � <br /> '� . BATHROOM MIRRORS NATIONAL ENERGY&LIGHT(PREFERRED) BATHROOM MIRROR nelcompany.com P:(603)864-8635 JIM SCHMIDT jschmidt@nelcompany.com ��� , ` ' � "'1-, ti <br /> � THE ADJACENT INTERIOR WALL UNLESS NOTED OTHERWISE 30"PE <br /> . QL-'�,' , HVAC° ,z� .y v� , ' .£_..,� �," -; . . STAIRS, 0. R PERSON <br /> , <br /> < <br /> ,� _.: <br /> ( EXIT 1: 68 CLEAR WIDTH AT DOOR-340 OCCUPANT CAPACITY OK <br /> J • HVAC EQUIPMENT CARRIER CARRIER HVAC EQUIPMENT carrier.com/carrieden/us P:(315)317-2481 PAUL WITZ paul.witz@carrier.utc.com �' ' ' ' ' ,.. ' _ ' ��..::� ,_' <br /> ( ) <br /> � ;; (,__, . } . � ��:.-,=' 22. GENERAL CONTRACTOR SHALL RETAIN ONE SET OF THE PLANS IN GOOD EXIT 2: 34 CLEAR WIDTH AT DOOR- 170 OCCUPANT CAPACITY(OK) <br /> HVAC EQUIPMENT YORK/JOHNSON CONTROLS JOHNSON CONTROLS HVAC EQUIPMENT 'ohnsoncontrols.com P: 405 419-6351 WALT JACOBE walt.'acobe 'ci.com <br /> J ( ) 1 @1 �` ��", . . �� '., '' <br /> S3: . <br /> � �,, <br />� ��� '� � CONDITION TO NOTE&DOCUMENT ALL CHANGES DURING CONSTRUCTION.THIS EXIT 3: 34"CLEAR WIDTH AT DOOR-170 OCCUPANT CAPACITY(OK) <br /> IT VENDORS , � ' } ,��: ';. <br /> � ;'wf;,' '�� �� �- W� � ,� SET OF PLANS SHALL BE RETURNED TO THE OWNER AS PART OF THE REQUIRED EXIT 4: 34"CLEAR WIDTH AT DOOR-170 OCCUPANT CAPACITY(OK) � <br /> � � STRUCTURED CABLING AUTOMATED SYSTEM DESIGN(ASD) STRUCTURED CABLWG asd-usa.com P:(828)624-1092 JOHN PERSUITfE jpersuitte@asd-usa.com �,,,�.� ��� r�:,� � � <br /> � MANAGED FIREWALL CERDANT MANAGED FIREWALL cerdant.com P:(877)616-9384 TODD BARRETf pf@cerdant.com ''� ,.,, � °- � s�: .t CLOSE OUT PACKAGE. TOTAL CAPACITY: 850 OCCUPANTS(OK� <br /> > CLUB WIRELESS DEEPBLUE CLUB WIRELESS deepbluecommunications.com P:(518)389-2719 REBECCA DOUGLAS rebecca@deepbluecommunications.com f `�-f `'.� <<.- ' ' <br /> ,r^-> .° 23. DEFERRED SUBMITTALS IX.ARRANGEMENT OF EXITS: <br /> W BACKUP INTERNET/CRADLEPOINT WYLESS BACKUP INTERNET/CRADLEPOINT wyless.com P:(617)863-3221 MATT'HEW TYRE planetfitness@wyless.com f �` � ,*` ' <br /> I LIG � »-ff v , ' � �. -�'.� THE FOLLOWING ITEMS WILL BE SUBMITTED AS DEFERRED SUBMITTALS BY THE A. SEPARATION OF EXITS:AT LEAST 2 EXITS SHALL BE PLACED A DISTANCE APART <br /> cp HTIN � °'�"'� ' � '�� `'� APPROPRIATE INSTALLING SUBCONTRACTOR OR VENDOR. FOR EACH DEFERRED - <br /> o � r;:,, ,��,.;,, �QUAL TO NOT LESS THAN ONE-HALF THE LENGTH OF THE MAXIMUM OVERALL <br /> , . <br /> GENERAL LIGHTING FIXTURES SPECIALTY LIGHTING GROUP HIGH BAY FIXTURES LED LIGHTING RECESSED LIGHTING TRACK LIGHTING ssli htin .com P: 508 922-0786 ' ' � '' <br /> M 9 9 ( ) ANUSHKAZARIAN ak@sslighting.com �;.X �,<, . ' -€ �,-;; < '�. <br /> ' ' ' SUBMITTAL ITEM THE SUBCONTRACTOR OR VENDOR SHALL FIRST SUBMIT <br /> " °' � " ' DIAGONAL DIMENSION OF THE AREA BEING SERVED 1015.2.1 FOR SPRINKLERED <br /> : � . . �.�%->.,,; <br /> ..; <br /> . . �.<.< .�� �. : . , , <br /> CO GENERAL LIGHTING FIXTURES NATIONAL ENERGY&LIGHT HIGH BAY FIXTURES LED LIGHTING RECESSED LIGHTING TRACK LIGHTING nelcom an .com P: 603 864-8635 JIM SCHMIDT schmidt nelcom an .co ^^ �. _ "�^�•�.. �= t .-�s :- . _ _ . Tnis drawin9 and tne desi9n snown is tne properry of tne <br /> � p y � � � @ p y m ;� ~``�r�;;_. r ' ` ;x ''� .;�,� SIGNEDANDSEALEDENGINEEREDDRAWINGSANDCALCULATIONSTOTHE E3UILDINGS, arcnite�t. Thereprod�otion,copyingoruseofthisdrawing <br /> i SPECIALTY FIXTURES SMD LIGHTS PF BRANDED SCONCES smdlights.com P:(505)247-4276 ELAINA BULOW elaina@smdlights.com �; '�?��{, � ` '�:� h�-`".;:� , without their written consent is prohibited and any <br /> ` `.` ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO SUBMITfAL TO THE BUILDING E3. MAXIMUM TRAVEL DISTANCE :250 FULLY SPRWKLERED(TABLE 1016.2) infringementwill be subject to legal action. <br /> � LocKeRS ,'rt� ��` �R 7 �.� -�.` t `��; OFFICIAL OR FIRE MARSHAL.ARCHITECT'S REVIEW WILL BE FOR GENERAL <br /> � LOCKERS MATERIAL HANDLING SALES,INC LOCKERS mathand.com P:(800)458-6870 DON HATHORN dhathom@mathand.com �z, , ; �'= t . � <br /> ,� ,; �4r ; U1 = � ,'<'� CONFORMANCE WITH THE BUILDING DESIGN ONLY.SUBCONTRACTOR OR <br /> � LOCKERS HOLLMAN,INC. LOCKERS hollman.com P:(972)815-4066 TINA SMITH tinas@hollman.com ;� �'':` �<" �f�; ' ' �-' `;: �� '" VENDOR SHALL BE RESPONSIBLE FOR DETERMINING SUBMITTAL REQUIREMENTS X. OTHER LIFE SAFETY CONSIDERATIONS(TENANTZ <br /> � SI�NA�E -;'. �"� `; �� f:. < A. MINIMUM CORRIDOR WIDTH:44 (1018.2) CdVE R <br /> .� ' ���r f , ; AND PAYMENT OF ALL FEES FOR SUBMITTALS.THE GENERAL CONTRACTOR IS „ <br /> O EXTERIOR SIGNAGE VIEWPOINT ILLUMINATED LOGO&CHANNEL LETTERS viewpointsign.com P:(508)393-8200 JEFF KWASS jeff@viewpointsign.com �''�,�` f . ', � � �<<t E3. MINIMUM AISLE WIDTH: 36 (1017.5) <br /> ,r'� RESPONSIBLE FOR COORDINATING THE TIMING OF SUBMITTALS SO AS TO NOT C. DEAD END CORRIDOR:20'MAXIMUM 1018.4 <br /> � EXTERIOR SIGNAGE IDENTITI RESOURCES EXTERIOR SIGNAGE identiti.net P:(847)702-0644 LINDSEY JERZYK Ijerzyk@identiti.net � �' ``� '�`� -'y'�' INTERFERE WITH OVERALL CONSTRUCTION SCHEDULE,ALLOWING TIME FOR „ � � <br /> � `"' [�. DOOR CLEAR WIDTH:32 MINIMUM (1008.1.1) <br /> � EXTERIOR SIGNAGE PRIDE SIGNS EXTERIOR SIGNAGE pridesigns.com P:(519)622-4040 x226 RANDY STANTON rstanton@pridesigns.com ��-��5 � � " "''` APPROPRIATE REVIEWS FOR ARCHITECT AND BUILDWG OFFICIAL OR FIRE ,� <br /> � EXTERIOR SIGNAGE BARLO SIGNS EXTERIOR SIGNAGE barlosigns.com P:(800)227-5674 x356 PAULA KELLEY paula_k@barlosigns.com MARSHAL. NO DELAYS OR TIME EXTENSIONS WILL BE ALLOWED FOR FAILURE TO �. STAIR CLEAR WIDTH:48 MINIMUM BETWEEN HANDRAILS (1009.4) <br /> � INTERIOR SIGNAGE/GRAPHICS/ NORTHEAST COLOR MANDATORY INTERIOR SIGNAGE 280 HERITAGE AVE. UNIT E fsi nsho .com/ f/xcart P: 603 436-8210 BILL FORTE f northeastcolor.com ° " �� E. NO EGRESS THRU STOCKROOMS <br /> p ( > p 9 p P ( ) p@ � , ALLOW APPROPRIATE TIME FOR REVIEW. F. INTERIOR FINISHES TABLE 803.9 SPRINKLERED <br /> -p DECALS/LUNK ALARM&LIGHT PORTSMOUTH,NH 03801 bill@northeastcolor.com F SEE SCHEDULE THIS SHEET � � <br /> � ; s._ <br /> � INTERIOR SIGNAGE/GRAPHICS/ SPECTRUM MARKETWG COMPANIES MARKETING&SIGNAGE FORMS,CARDS, ETC. 95 EDDY RD.STE 101 P:(603)627-0042 JANINE SOFFRON janine@spectrummarketing.com t E� � � ' z ' 1.VERTICAL EXITS/PASSAGEWAYS: CLASS B (NONE PRESENT) <br /> � DECALS/LUNK ALARM&LIGHT (MANDATORY) MANCHESTER,NH 03102 `� : E �' < =- ,-^''•; 2. ROOMS/ENCLOSED SPACES: CLASS C <br /> � INTERIOR SIGNAGE/GRAPHICS/ DUNN BLUE(MANDATORY) INTERIOR SIGNAGE 1009 W.MAPLE RD. pfsignage.com P:(248)288-5600 BILL DUNN bill.dunn@dunnblue.com 3. FLOOR FINISHES: FLOOR FINISH MATERIALS MUST COMPLY <br /> j DECALS/LUNK ALARM&LIGHT ctAWSON,MI 4so17 SMOKESRATING NOTT O EXCEED 450 PER ASTME 61�12C OPTICAL DENSITY <br /> U <br />