Permit#: M1705-024
<br /> Site Address: 7621 EVERGREEN WAY
<br /> DUCT LINE EQUIVALENTS LEGEND GENERAL PIPING ABBREVIATIONS (CONTINUED) VICINITY MAP �wner: COLUM6IAC�\SCqpEpLAZqLLC
<br /> Tenant: PLANET FITNFSS
<br /> App.Date: 5/12/ZQ17
<br /> GALV GALVANIZED LEGAL DESCRIPTION
<br /> Proposed Use: COMMERCIAL
<br /> SINGLE LINE DOUBLE LINE DESCRIPTION SYMBOL ABBR DESCRIPTION SYMBOL ABBR DESCRIPTION GPM GALLONS PER MINUTE SEC 07 TWP 28 RGE 05TRACT 2 OF BSP REC VOL 1 OF BSP'S PGS 196 THRU 198 AF NO 8912085005 BEING A PTN OF NE1/4 FQR�trOn� MECHANICALSYSTEMMODIFICATIONS
<br /> GWB GYPSUM WALLBOARD SW1 4
<br /> � AAV AUTOMATIC AIR VENT / Review�d By: ;r(\�� t%�Pf l.
<br /> �--� 90° ELBOW UP (SUPPLY) � 45° ELBOW HC HEATING COIL
<br /> — BFW— BFW BOILER FEED WATER HORIZ HORIZONTAL PARCEL NUMBER � Date: � 1�� C�!
<br /> 90° ELBOW UP RETURN EXHAUST HP HORSEPOWER 1�i of�ice set ;
<br /> � / � C 45° DOWN —BWS— BWS BEAM WATER SUPPLY 28050700300100 � r � k�, ob Site Set Fire/Pianning Set
<br /> HT HEAT TRACE ;�� � ,, ,��,�`-'�
<br /> ❑--� ' 90° ELBOW DOWN (SUPPLY) � —BWR— BWR BEAM WATER RETURN HVAC HEATING, VENTILATING, AND AIR CONDITIONING �
<br /> 90° ELBOW HX HEAT EXCHANGER
<br /> �
<br /> ID INDiRECT DRAIN INSIDE DIAMETER PROJECT LOCATION PLRNNING � �
<br /> �--� 90° ELBOW DOWN (RETURN/EXHAUST) � �� BUCKET STEAM TRAP _ /�
<br /> AD ACCESS DOOR IN CEILING IN INCH " / ' (NTERIDRS (P)615.244.8170
<br /> �--�—� RADIUS ELBOW UP (SUPPLY) —CA— CA CONTROL AIR KW KILOWATT ., /- www.mjma ch.scom1
<br /> LAT LEAVING AIR TEMPERATURE GRAPHICS
<br /> � AD ACCESS DOOR IN WALL —CHR— CHR CHILLED WATER RETURN �
<br /> �--�—� RADIUS ELBOW UP (RETURN/EXHAUST) LB POUND
<br /> — — CHS— CHS CHILLED WATER SUPPLY LWT LEAVING WATER TEMPERATURE `'`
<br /> — ALIGNMENT GUIDE � �-' � � - �
<br /> �,- .. =
<br /> MBH THOUSAND BTU PER HOUR
<br /> �--�—� RADIUS ELBOW DOWN (SUPPLY) �� ANCHOR —CR CR CONDENSER WATER RETURN MECH MECHANICAL � ,,_,, , V
<br /> CS CS CONDENSER WATER SUPPLY MOD MOTOR OPERATED DAMPER �P�- Wq ��
<br /> ❑--�—� RADIUS ELBOW DOWN (RETURN/EXHAUST) MTD MOUNTED °- � ° ��, °F S�S'i,��
<br /> � AUTOMATIC CONTOL VALVE (3-WAY) � � FLANGE NC NORMALLY CLOSED / NOISE CRITERIA � � �� o v
<br /> �—� R O U N D D U C T U P (S/R/E) N I C N O T I N C O N T R A C T N
<br /> � AUTOMATIC CONTROL VALVE (2-WAY) �"��"� FLEX NO NORMALLY OPEN / NUMBER
<br /> � ROUND DUCT DOWN S R E NTS NOT TO SCALE `� � sszao c�,�
<br /> C� � � � � T FLOAT AND THERMOSTATIC STEAM TRAP � = �
<br /> TURNING VANE ELBOW � BALANCING VALVE — FOR— FOR FUEL OIL RETURN OCD ONP�CENT�ER�DE DAMPER n �,��,SS oNAL��G��'�"
<br /> —I jl— BV BALL VALVE — FOS— FOS FUEL OIL SUPPLY OD OUTSIDE DIMENSION OR DIAMETER , _ �
<br /> OSA OUTSIDE AIR � � �� � � � �
<br /> RADIUS ELBOW, RECT — FOV— FOV FUEL OIL VENT PD PRESSURE DROP / PUMPED DRAIN , � 4 � ��/��/2�I�
<br /> oP xx'-xx" BOP BOTTOM OF PIPE ELEVATION PL PLENUM , J
<br /> G G NATURAL GAS POC POINT OF CONNECTION v'
<br /> u. -
<br /> .��. .... a�� � Q
<br /> � BREAK — HCR— HCR HIGH PRESSURE CONDENSATE RETURN PT POST-TENSION SLAB W
<br /> RA RETURN AIR , � �
<br /> REF REFERENCE ` �� � �� '
<br /> RADIUS ELBOW, ROUND HG HG HOT GAS ,,;,.
<br /> —�1f— BFV BUTTERFLY VALVE �
<br /> —NPS— HPS HIGH PRESSURE STEAM REV REVISION
<br /> C CAP RF RELIEF FAN
<br /> —HWR— HWR HEATING HOT WATER RETURN RH RELATIVE HUMIDITY
<br /> �—�—� TRANSITION (ROUND TO ROUND/ � CENTERLINE SA SUPPLY AIR
<br /> RECTANGULAR TO RECTANGULAR) —HWS— HWS HEATING HOT WATER SUPPLY SENS SENSIBLE
<br /> � xx'-xx" CL-EL CENTERLINE OF PIPE ELEVATION SF SUPPLY FAN / SQUARE FOOT
<br /> �—� TRANSITION (RECTANGULAR TO ROUND) — LCR— LCR LOW PRESSURE CONDENSATE RETURN SL SOUND LINE (INSIDE DUCT INSULATION )
<br /> �� CHK CHECK VALVE SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION
<br /> � RECT SPIN-IN TAKEOFF — LPS— LPS LOW PRESSURE STEAM SP STATIC PRESSURE
<br /> �--ROUND=-- --�— CIRCUIT SETTER SS STAINLESS STEEL
<br /> � MAV MANUAL AIR VENT ST SOUND TRAP NORTH ARROW
<br /> TCV TEMPERATURE CONTROL VALVE � UNIVERSITY
<br /> ROUND —MCR— MCR MEDIUM PRESSURE CONDENSATE RETURN TDH TOTAL DYNAMIC HEAD MECHANICAL
<br /> CONICAL TEE X DETAIL OR ENLARGED PLAN, NUMBER FOR DEfAIL, TOD TOP OF DUCT CONTRACTORS INC.
<br /> E—ROUND—� X_X LETTER FOR ENLARGED PLAN TAG �� METER REFER TO PLANS FOR METER SERVICE TOS TOP OF STEEL '
<br /> TP TOTAL PRESSURE CODE REFERENCES WeeuildValue
<br /> � TEE WITH TURNWG VANES —MG— MG MEDIUM PRESSURE NATURAL GAS TSP TOTAL STATIC PRESSURE
<br /> C DN DOWN 11611 49th Place West, �
<br /> —MPS— MPS MEDIUM PRESSURE STEAM nP TYPICAL Mukilteo, Washington 98275
<br /> UBD UPBLAST DISCHARGE Phone: (206) 364-9900 Z
<br /> BRANCH TAKEOFF, RECT UH UNIT HEATER 2015 INTERNATIONAL MECHANICAL CODE (IMC)� Fax: (206) 361-2126 Q
<br /> X ELEVATION TAG — PCR— PCR PUMPED CONDENSATE RETURN UNO UNLESS NOTED OTHERWISE 2015 WASHINGTON STATE ENERGY CODE (WSEC)# www.umci.com �
<br /> L-�-+ SP*-*
<br /> P� PI PRESSURE INDICATOR VA VALVE 2015 INTERNATIONAL FUEL GAS CODE (IFGC)� J
<br /> VAV VARIABLE AIR VOLUME
<br /> RECT ► FLOW ARROW —RL RL REFRIGERANT LIQUID VD VOLUME DAMPER 2015 UNIFORM PLUMBING CODE (UPC)' �
<br /> BRANCH TAKEOFF, ROUND
<br /> �--ROUND--� RS RS REFRIGERANT SUCTION VENT VENTILATION / VENTILATOR 2015 INTERNATIONAL BUILDING CODE (IBC)� �
<br /> --�j}— GAS COCK VEL VELOCITY 2015 INTERNATIONAL FIRE CODE (IFC)� Z
<br /> T TEMPERATURE PRESSURE TEST PLUG W INSULATED DUCT / WATT / WIDE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) RECOMMENDATIONS O
<br /> RECT BRANCH TEE, RECT �� GLOBE VALVE WB WET BULB (TEMPERATURE)
<br /> T� TI TEMPERATURE INDICATOR WG WATER GAUGE � INCLUDING AMENDMENTS BY THE STATE OF WASHINGTON AND RUTHORIn HAVING JURISDICTION V
<br /> �� GV GATE VALVE TS TEMPERATURE SENSOR WT WEIGHT
<br /> TS
<br /> RECT iE xx'-xx" IE INVERT PIPE ELEVATION � VB VACUUM BREAKER
<br /> CONICAL SPIN-IN TAKEOFF
<br /> =—ROUND� PITCH VENTURI �
<br /> �
<br /> �iX• �F� PITCH LE�f —G�—
<br /> �.,
<br /> PITCH „�`'� �
<br /> ROUND BOOT TEE ��' �+� PITCH RIGHT `�
<br /> � � v-.
<br /> �R°��°-' '- ���� ABBREVIATIONS GENERAL NOTES MECHANICAL INDEX OF DRAWINGS r����� ��
<br /> � POC POINT OF CONNECTION
<br /> 45° LATERAL � " �
<br /> �--� � PG PRESSURE GAUGE AC AIR CONDITIONING UNIT 1. THE MECHANICAL SYSTEM SNALL CONSIST OF ALL WORK SHOWN ON DRAWINGS, SHEET � DESCRIPTION SCALE
<br /> AFF ABOVE FINISHED FLOOR DIAGRAMS AND AS DESCRIBED lN SPECIFICATIONS. '
<br /> 45° CONICAL LATERAL � PRV PRESSURE REDUCING VALVE AHU AIR HANDLING UNIT M001 LEGEND, ABBREVIATIONS, GENERAL NOTES NTS
<br /> �� AMS AIRFLOW MEASURING UNIT 2. DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT SHOW EXACT ROUTING OR ALL
<br /> —+C�� ROLLING 45 DOWN TRANSITIONS/CONNECTIONS/OFFSETS REQUIRED. M002 PERMIT NOTES & CALCULATIONS NTS
<br /> --� R ELEVATION CHANGE B BOILER 3. INSTALL MECHANICAL WORK AS HIGH AS POSSIBLE, TIGHT TO STRUCTURE ABOVE M101 MECHANICAL SCHEDULES NTS
<br /> `��� — R RISE (R) OR DROP (D) —f-- REDUCER BDD BACKDRAFT DAMPER UNLESS NOTES OTHERWISE. P LAN ET
<br /> BOD BOTTOM OF DUCT
<br /> F---z � AIR FLOW DIRECTION - SUPPLY BOT BOTTOM MD201 LEVEL 1 - HVAC DEMO PLAN 1/8" = 1'-0° FITNESS - TN
<br /> �-- �— �� REDUCING CONCENTRIC BTUH BRITISH THERMAL UNIT PER HOUR 4. ITEMS NOTES AT "TYPICAL" OR "TYP" ON ANY DRAWING APPLY TO THAT PARTICULAR M201 LEVEL 1 - HVAC PLAN 1/8° = 1'-0"
<br /> DRAWING.
<br /> �� �� AIR FLOW DIRECTION - � REDUCING ECCENTRIC
<br /> RETURN OR EXHAUST CC COOLING COIL M301 MECHANICAL DETAILS NTS p�
<br /> CFM CUBIC FEET PER MINUTE 5. COORDINATE EXACT LOCATIONS OF ALL ROOM THERMOSTATS AND/OR ROOM
<br /> RV RELIEF VALVE TEMPERATURE SENSORS WITH ARCHITECT PRIOR TO INSTALLATION. PROVIDE A W
<br /> �---� � DUCT END CAP CHLR CHILLER THERMOSTAT LOCATION SHOP DRAWING FOR APPROVAL. MOUNT WALL THERMOSTAT AT
<br /> x DRAWING NOTE DESIGNATION CLG CEILING 48" A.F.F. UNLESS COORDINATED OTHERWISE WITH ARCH�OWNER. 161 BELLE FOREST RD. Z
<br /> �
<br /> �����i% CNTFGL CENTRIFUGAL #208 �
<br /> ��%il�l�llil FLEXIBLE DUCTWORK --�— SLEEVE COND CONDENSER / CONDENSATE 6. PROVIDE CONNECTIONS AND TRANSITIONS AT EQUIPMENT AS REQUIRED. NASHVILLE, TN 37221 O
<br /> 4 CP CIRCULATING PUMP
<br /> ��� MANUAL VOLUME DAMPER --d4— SV SOLENOID VALVE CT COOLING TOWER 7. INSTALLATION SHALL COMPLY TO ALL FEDERAL, STATE AND LOCAL CODES.
<br /> CU CONDENSING UNIT / CUBIC
<br /> R R �— TEE DOWN CV CONSTANT VOLUME 8. INSULATION OF DUCT WORK AND PIPING SHALL CONFORM TO THE WASHINGTON STATE
<br /> '�—� REMOTE VOLUME DAMPER CWP CHILLED WATER PUMP ENERGY CODE AND THE EVERETT AMENDMENTS.
<br /> FSD FSD � TEE
<br /> z--�---�' FIRE/SMOKE DAMPER - PROVIDE ACCESS �_ D DRAIN 9. ALL DUCT DIMENSIONS ARE ID (INTERNAL DIMENSIONS). ALL DUCT HEIGHTS ABOVE
<br /> TH THERMOMETER DB DRY BULB / DECIBEL THE FINISHED FLOOR ARE TAKEN FROM THE DUCT'S ID DIMENSIONS. CONTRACTOR IS
<br /> � FD DEG DEGREE REQUIRED TO ADD TO THE DUCT ID WHEN THE DUCTWORK HAS INTERIOR INSULATION.
<br /> FIRE DAMPER - PROVIDE ACCESS xxxXXxxxx LONG TAG 9 CHARACTERS MAX DIA DIAMETER ALL MECHANICAL ELEVATION ARE TO BOTTOM OF DUCT, BOTTOM OF PIPE.
<br /> MOD �, XXXXXX MEDIUM TAG 6 CHARACTERS MAX DNPR DOWNER 10. MANUAL VOLUME DAMPERS ARE REQUIRED AT EACH BRANCH DUCT GOING TO A
<br /> �� �� MOTOR OPERATED DAMPER SUPPLY AIR, RETURN AIR, AND EXHAUST AIR OUTLET OR INLET.
<br /> "' � NEED�E ISOLATION VALVE EA EXHAUST AIR
<br /> BDD BDD 11. ACCESS DOORS SHALL BE REQUIRED AT EACH FIRE DAMPER, FIRE SMOKE DAMPER,
<br /> �--�--2 BACKDRA�f DAMPER EAT ENTERING AIR TEMPERATURE �
<br /> xxXx SHORT TAG 4 CHARACTERS MAX ECONO ECONOMIZER AND WHERE ACCESS TO ANY DEVICE IS REQUIRED FOR OPERATION OF THAT ��-� � PLAN ET
<br /> H H EDH ELECTRIC DUCT HEATER
<br /> DEVICE. i����� �j c�
<br /> �---�� 4 � F ITN ESS
<br /> HUMIDIFIER oP xx'-xx" TOP TOP OF PIPE ELEVATION EER ENERGY EFFICIENCY RATIO 12. REFERENCE STRUCTURAL DRAWWGS FOR ACCEPTABLE POST-INSTALLED ANCHORS TO �. "
<br /> EF EXHAUST FAN �� `
<br /> ELEC ELECTRIC SUPPORT MECHANICAL EQUIPMENT OR DUCTWORK FROM THE SLAB. �., _. _
<br /> ��� WALL MOUNTED TSTAT WITH CONTROL LINE �I� U UNION �""�=-- �
<br /> ELEV ELEVATION �
<br /> � 13. COORDINATE ALL MECHANICAL WORK WITH OTHER TRADES TO INSURE PROPER AND '�' Z
<br /> � ESP EXTERNAL STATIC PRESSURE O
<br /> SUPPLY GRILLE OR DIFFUSER � UP ADEQUATE CLEARANCE. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL
<br /> • VERTICAL SLEEVE EWT ENTERING WATER TEMPERATURE WORKING CLEARANCES FOR ALL ELECTRICAL AND MECHANICAL EQUIPMENT. �� _
<br /> � RETURN�EXHAUST GRILLE EXH EXHAUST ; ��� � � ����� ,� _ �; ` , - � CASCADE PLAZA �
<br /> + VALVE IN PIPE RISE OR DROP EXT EXTERIOR / EXTERNAL 14. MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEATING DURING ' ' , � �� �� 7621 EVERGREEN WAY
<br /> EF-X EQUIPMENT MARK CONSTRUCTION. �� � �' EVERETT, WA. a
<br /> �o STR WYE TYPE STRAINER FCU FAN COIL UNIT � V
<br /> o- 200 DIFFUSER/GRILLE DESIGNATION �� FD FIRE DAMPER / FLOOR DRAIN 15. SEISMIC CALCULATIONS WILL BE A DEFERRED SUBMITTAL THROUGH THE BUILDING Q
<br /> � WYE TYPE STRAINER WITH VALVE AND HOSE END FLTR FILTER PERMIT APPLICATION. ' '
<br /> " J
<br /> � ROUND DUCT FPM FEET PER MINUTE �.
<br /> ��J FSD FIRE SMOKE DAMPER � �
<br /> T=� � AUTOMATIC INTERLOCKED FT FEET
<br /> B_ TOP OF DUCT, BOTTOM OF DUCT L~�
<br /> - �j T 2-WAY BUTTERFLY VALVE F-fU FAN TERMINAL UNIT PERMIT SET
<br /> FV FACE VELOCITY W
<br /> 0 3/ 17/2 017 �
<br /> Q
<br /> MJM # XXXXX �
<br /> NO. DESCRIPTION DATE
<br /> V�
<br /> Z
<br /> 0
<br /> � —
<br /> �
<br /> �
<br /> �
<br /> W
<br /> �
<br /> This drawing and the design shown is the property of the
<br /> architect. The reproduction,copying or use of this drawing
<br /> without their written consent is prohibited and any
<br /> infringement will be subject to legal action.
<br /> LEGEND,
<br /> ABBREVIATIONS,
<br /> GENERAL NOTES
<br /> �
<br /> W
<br /> W
<br /> _
<br /> �
<br />
|