FIRE DEPARTMENT NOTES DISABLED ACCESS NOTES GENERAL NOTES
<br /> 1. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, 1. THE AMERICANS WITH DISABILITES ACT (A.D.A.) PROVIDES THAT ALL 1. ALL WORK SHALL CONFORM TO THE AMERICAN WITH DISABILITIES 18. THE CONTRACTOR SHALL LAYOUT THE WORK AND SHALL ESTABLISH
<br /> WHERE SHOWN ON DRAWINGS, AND ADDITIONAL SIGNS AS ALTERATIONS TO A FACILITY MUST BE MADE IN SUCH A MANNER ACT (A.D.A.) ALONG WITH ALL STATE, COUNTY, AND LOCAL AND MAINTAIN NECESSARY MARKERS, AND SHALL BE RESPONSIBLE
<br /> REQUIRED BY BUILDING DEPARTMENT INSPECTOR OR FIRE THAT, TO THE MAXIMUM EXTENT FEASIBLE, THE ALTERED PORTIONS APPLICABLE CODES, ORDERS, ORDINANCES AND REGULATIONS. FOR THE ACCURACY OF SAME. THE CONTRACTOR SHALL LAYOUT, .,
<br /> DEPARTMENT FIELD INSPECTOR. CONNECT EXIT SIGNS TO OF THE FACILITY ARE READILY ACCESSIBLE TO INDIVIDUALS WITH NOTIFY ARCHITECT PRIOR TO START OF WORK OF ANY AS A GUIDE TO ALL TRADES AND TO HIS SUBCONTRACTORS, THE
<br /> EMERGENCY POWER CIRCUITS. COMPLY WITH BUILDWG CODES. DISABILITIES. BANK AND GENERAL CONTRACTOR ACKNOWLEDGES DISCREPANCIES BETWEEN THE DRAWINGS AND CODE. ALL WORK EXACT LOCATIONS OF NEW OR REMODEL WORK WITH RESPECT TO '
<br /> 2 MAINTAIN AISLES AT LEAST 44" WIDE AT PUBLIC AREAS. THAT THE REQUIREMENTS OF A.D.A. WILL BE SUBJECT TO VARIOUS SHALL CONFORM TO THE MOST RESTRICTIVE REQUIREMENT. CHANGES TO EXISTING. ADA UPGRADE
<br /> AND POSSIBLY CONTRADICTORY INTERPRETATIONS. THE
<br /> ' 3 EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT qRCHITECT THEREFORE, WILL USE IT'S BEST PROFESSIONAL 2. BEFORE COMMENCING WORK, CONTRACTOR SHALL BECOME 19. INSTALL AND APPLY ITEMS, MATERIALS, EQUIPMENT, FINISHES, ETC.
<br /> THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. FAMILIAR WITH DRAWINGS SCOPE OF WORK AND VERIFY EXISTING INCLUDING THE PREPARATION OF SURFACES IN STRICT EVERGREEN & SOth
<br /> SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. ALL EFFORTS TO INTERPRET A.D.A. REQUIREMENTS AND OTHER CONDITIONS AND DIMENSIONS AT THE SITE AND NOTIFY THE ACCORDANCE WITH THE MANUFACTURER'S PRINTED
<br /> � NEW DOORS SHALL HAVE APPROVED LEVER HANDLES. FEDERAL, STATE AND LOCAL LAWS, RULES, CODES ORDINANCES ARCHITECT OF ANY DISCREPANCIES. RECOMMENDATIONS AND INSTALLATION REQUIREMENTS.
<br /> AND REGULATIONS AS THEY APPLY TO THE PROJECT. THE
<br /> 4 DOOR OPENINGS INTO REQUIRED 1-HOUR, FIRE-RESISTIVE ARCHITECT, HOWEVER, CANNOT AND DOES NOT WARRANT OR 3. PRIOR TO STARTING WORK, THE GENERAL CONTRACTOR SHALL 20. PERTAINING TO EQUIPMENT: GENERAL CONTRACTOR IS 5019 Evergreen Way
<br /> CORRIDORS SHALL BE PROTECTED WITH A SMOKE OR DRAFT STOP GUARANTEE THAT BANK OF AMERICA WILL COMPLY WITH ALL SUBMIT TO BANK OF AMERICA PROJECT MANAGER AND ARCHITECT RESPONSIBLE FOR THE REMOVAL AND RELOCATION OF ANY
<br /> ASSEMBLY HAVING A 20 MINUTE RATING AND SHALL BE INTERPRETATIONS OF THE A.D.A. REQUIREMENTS AND/OR THE AN ITEMIZED COST BREAKDOWN OF ALL SCOPE ITEMS AND A EXISTING EQUIPMENT OR CONSTRUCTION AS NECESSARY FOR A Everett, WA 98203
<br /> SELF-CLOSING. REQUIREMENTS OF OTHER FEDERAL, STATE AND LOCAL LAWS, CONSTRUCTION SCHEDULE. WORK TO BE SCHEDULED TO MEET COMPLETE INSTALLATION.
<br /> 5 20-MINUTES DOOR JAMBS TO BE TIGHT-FITTIN, SMOKE AND DRAFT RULES, CODES, ORDINANCES AND REGULATIONS AS THEY APPLY TO BANK OF AMERICA REQUIREMENTS. 21. ACCESS PANELS SHALL BE PROVIDED FOR ALL EQUIPMENT
<br /> CONTROLLED. THE PROJECT. 4. ALL WORK DESCRIBED OR INDICATED IN THESE DOCUMENTS AND SWITCHES, VALVES AND OTHER CONTRO� DEVICES THAT ARE
<br /> 6 EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN 2, THE SCOPE OF WORK INDICATED IN THESE DRAWINGS IS FOR ALL WORK DEPENDENT UPON OR NECESSARY TO GOMPLETE THIS CONCEALED. EXACT LOCATIONS TO BE APPROVED BY ARCHITECT
<br /> SERVING 50 OR MORE PERSONS AND IN ANY HAZARDOUS AREAS. SPECIFIC ITEMS SELECTED BY BANK OF AMERICA FOR CUSTOMER WORK SHALL BE EXECUTED IN A WORKMAN LIKE MANNER PRIOR TO INSTALLATION.
<br /> 7 INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDORS SHALL ACCESS TO GOODS AND SERVICES. NOTE THAT SOME AREAS OF CONSISTENT WITH THE BEST STANDARDS OF THE TRADE INVOLVED 22, BESIDES GUARANTEES REQUIRED ELSEWHERE, THECONTRACTOR
<br /> NOT EXCEED AND END POWT FLAME SPREAD RATING: ACCESS HAVE NOT BEEN MODIFIED TO MEET A.D.A. REQUIREMENTS. AND BE OF ITEMS AND MATERIALS SUITED FOR THE PURPOSE SHALL, HEREBY DOES, GUARANTEE ALL WORK FOR A MINIMUM
<br /> � INTENDED. PERIOD OF ONE YEAR AFTER DATE OF ACCEPTANCE OF WORK
<br /> 8 CLASS A, FLAME SPREAD 0-25, SMOKE DEVELOP INDEX 450, FOR ALL OTHER AREAS OF A.D.A. UPGRADE THAT MAY BE REQUIRED AT
<br /> MATERIALS INSTALLED IN VERTICAL EXITS. THIS TIME ARE NOT IN THIS CONTRACT AND ARE NOT INDICATED ON 5. TRADESMEN, CRAFTSMEN, INSTALLERS, FOREMEN, AND WITH ANY OTHER WORK, WHICH MAY BE DISPLACED IN SO DOING,
<br /> THESE DOCUMENTS. SEE BANK OF AMERICA FOR ADDITIONAL SUPERVISORS ARE TO BE SKILLED, EXPERIENCED AND LICENSED IF THAT MAY PROVE DEFECTIVE IN WORKMANSHfP AND/OR MATERIALS
<br /> 9 CLASS B, FLAME SPREAD 26-75, SMOKE DEVELOP INDEX 450, FOR WFORMATION CONCERNING OTHER AREAS OF A.D.A. SCOPE OF REQUIRED IN THE WORK THEY WILL BE PERFORMING. WITHIN A MINIMUM OF ONE YEAR PERIOD FROM THE DATE OF 2101 Webster Street
<br /> MATERIALS INSTALLED IN HORIZONTAL EXITS. WORK. 6. PROJECT CONSTRUCTION ITEMS TO BE NEW, UNLESS OTHERWISE ACCEPTANCE WITHOUT EXPENSE TO BANK OF AMERICA. Suite 2000
<br /> 10 CLASS C, FLAME SPREAD 76-200, SMOKE DEVELOP INDEX 450, FOR NOTED. NO SUBSTITUTIONS WILL BE ALLOWED UNLESS COMPLETE 23. GC/CONTRCTOR TO OBTAIN AND PAY FOR PERMITS AND Oakland CA 92660
<br /> MATERIALS INSTALLED IN ANY OTHER LOCATION. 3. IN BUILDING AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE DESCRIPTIONS OF ITEMS INCLUDING DRAWINGS, TEST DATA,
<br /> A COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES GOVERNING THE Tel: 510.625.7400
<br /> 11 PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE SAMPLES, COST AND SCHEDULE CHANGES ARE SUBMITTED BY THE WORK. ��SI�� Fax: 510.625.7499
<br /> • FIRE-RATED WALLS OR CEILINGS. PEDESTRIAN RAMPS, PASSENGER ELEVATORS OR SPECIAL ACCESS CONTRACTOR AND APPROVED BY THE ARCHITECT PRIOR TO
<br /> LIFTS. INSTALLATION. ANY ITEM NOTED ON THE DRAWINGS THAT ARE NOT 24. GC/CONTRCTOR TO SUBMIT REQUESTS FOR SUBSTITUTIONS,
<br /> 12 WOOD BLOCKING SHALL BE FIRE-TREATED IN ACCORDANCE WITH 4. FLOOR SURAFCES SHALL BE SLIP-RESISTANT. REVISIONS, OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO
<br /> APPLICABLE CODES. AVAILABLE OR WOULD CAUSE A TIME DELAY SHALL BE IDENTIFIED PURCHASE, FABRICATION OR INSTALLATION.
<br /> ' 13 HEARING IMPAIRED: FLASHING VISUAL WARNINGS SHALL HAVE A 5. EVERY CORRIDOR AND AISLE SERVING AN OCCUPANT LOAD OF 10 BY THE GENERAL CONTRACTOR AND THE ARCHITECT NOTIFIED. 25. GC/CONTRCTOR TO PROVIDE WORK NOTED "BY OTHERS" OR "NIC"
<br /> FREQUENCY OF NOT MORE THAN 60 FLASHES PER MINUTE, AND OR MORE, SHALL BE NOT LESS THAN 44" IN WIDTH. 7. TYPICAL DETAILS AND GENERAL NOTES SHALL BE USED WHENEVER
<br /> 6. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL UNDER SEPARATE CONTRACT. INCLUDE SCHEDULE REQUIREMENTS
<br /> SHALL BE SYNCHRONIZED. APPLICABLE U.N.O. ALL SYMBOLS AND ABBREVIATIONS USED ON THE IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO
<br /> 14 LOCATE THE CENTER OF FIRE ALARM INITIATING DEVICES 48" ABOVE NOT EXCEED 1/2" IN HEIGHT. LEVEL CHANGES NOT EXCEEDING 1/4" DRAWINGS ARE CONSIDERED CONSTRUCTION STANDARDS. IF ASSURE ORDERLY SEQUENCE OF INSTALLATION
<br /> THE LEVEL OF THE FINISHES FLOOR, WORKING PLATFORM, GROUND MAY BE VERTICAL. BEVEL OTHERS WITH A SLOPE NOT GREATER CONTRACTOR HAS ANY QUESTIONS REGARDING THE SAME OR 26. GC/CONTRCTOR TO COORDINATE TELECOMMUNICATIONS, DATA AND
<br /> SURFACE OR SIDEWALK. THAN 1:2. EXACT MEANING, ARCHITECT SHALL BE NOTIFIED FOR
<br /> 7. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND CLARIFICATION. SECURITY SYSTEM INSTALLATIONS.
<br /> 15 CONTRACTOR SHALL PERMANENTLY INDENTIFY ALL PROTECTED WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A 27. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE.
<br /> OPENINGS, CORRIDOR PARTITIONS, SMOKE PARTITIONS, 8. DIMENSION LINES ARE TO FACE OF FINISH ON EXISTING AND NEW
<br /> EXIT ENCLOSURES AND ALL FIRE SINGLE EFFORT BY LEVER. TYPE HARDWARE, PANIC BARS, WORK UNLESS NOTED AS FACE OF STUD OR MASONRY OR 28. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE
<br /> ' HORIZONTAL EXIT PARTITIONS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO � OF CONFLICT, CONSULT THE ARCHITECT.
<br /> RATE WALLS WITH CORRESPONDING HOURLY RATING BY EITHER CENTERLINE OR OTHERWISE. DIMENSIONS SHALL HAVE
<br /> INSTALLING SIGNS OR BY STENCILING IN CONCEALED SPACES THE PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP PRECEDENCE OVER SCALE AND LARGER SCALE DRAWINGS SHALL 29. COORDINATE AND PROVIDE BLOCKING FOR MILLWORK AND ITEMS
<br /> ' FOLLOWING: "1 HOUR FIRE AND SMOKE BARRIER - PROTECT ALL THE OPENING HARDWARE. MOUNT DOOR OPENING HARDWARE HAVE PRECEDENCE OVER SMALLER SCALE DRAWINGS. ATTACHED OR MOUNTED TO WALLS OR CEILINGS.
<br /> OPENINGS." NOTE: IDENTIFICATION SHALL BE SPACED NO MORE BETWEEN 30" AND 44" ABOVE FLOOR FINISH. g, PROVIDE SHOP DRAWINGS WHERE INDICATED AND FOR ALL METAL 30. UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH,
<br /> THAN 30 FEET ON CENTER WITH A MINIMUM LETTER SIZE OF THREE 8. CENTER HAND ACTIVATED DOOR OPENING HARDWARE BETWEEN FABRICATION OR WHERE THEY ARE CALLED OUT FOR ON THE UNLESS OTHERWISE NOTED.
<br /> (3) INCHES IN HEIGHT ON A CONTRASTING BACKGROUND. 30" AND 44" ABOVE THE FLOOR. CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL SUBMIT 31. CONCEALED INSULATING MATERIALS INSTALLED WITHIN WALL SHALL
<br /> 9. MAXIMUM PULL OR PUSH EFFORT TO OPERATE DOORS SHALL NOT FIVE (5) SETS TO THE ARCHITECT WITH AMPLE TIME TO REVIEW. HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 75 AND A
<br /> EXCEED 8.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR REQUIRED CORRECTIONS WILL BE NOTED AND A COPY WILL BE SMOKE-DEVELOPED INDEX OF MOT MORE THAN 450.
<br /> INTERIOR DOORS, MEASURED AT RIGHT ANGLES TO HINGED DOORS RETURNED TO THE CONTRACTOR WHO SHALL REVISE DRAWINGS 32. INSULATWG MATERIALS WHICH ARE SUBJECT TO DIRECT EXPOSURE
<br /> AND AT CENTER PLANE OF SLIDING OR FOLDING DOORS. AND RESUBMIT FOR FINAL APPROVAL PRIOR TO FABRICATION. TO POTENTIAL FIRE ON THE INSIDE OF THE BUILDING DUE TO
<br /> . CORRESPONDING DEVICES OR AUTOMATIC DOOR OPERATORS MAY 10. CONTRACTOR TO SUBMIT SAMPLES OF ALL FINISH MATERIALS TO INSTALLATION IN UNCONCEALED SPACES SHALL HAVE A FLAME
<br /> BE UTILIZED TO MEET THE ABOVE STANDARDS. MAXIMUM EFFORT ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED
<br /> TO OPRATE REQUIRED FIRE DOORS MAY BE INCREASED NOT TO 11. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF AS-BUILT INDEX OF NOT MORE THAN 450.
<br /> , EXCEED 15 POUNDS. DRAWINGS NOTING DEVIATIONS BETWEEN THESE DRAWINGS AND 33. MATERIALS EXPOSED WITHIN PLENUMS ARE REQUIRED TO BE
<br /> 10. THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) ACTUAL FIELD CONDITIONS AND NEW CONSTRUCTION OF ALL NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT
<br /> SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE TRADES AND DELIVER TO BANK OF AMERICA AT END OF PROJECT. MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE
<br /> DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT GENERAL CONTRACTOR SHALL PROVIDE ALL SUBCONTRACTORS THAN 50 AS DETERMINED IN ACCORDANCE WITH ASTM E 84.
<br /> CREATING A TRAP OR HAZARDOUS CONDITION. PROVIDE A 10" HIGH WITH THE MOST CURRENT CONSTRUCTION DOCUMENTS
<br /> SMOOTH PANEL ON THE PUSH SIDE OF NARROW FRAME DOORS. THROUGHOUT THE PROJECT, INCLUDING ALL REVISIONS.
<br /> 11. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL NOT 12. CONTRACTOR TO NOTIFY ARCHITECT AND BANK OF AMERICA
<br /> BE LESS THAN 3' IN WIDTH IN NOT LESS THAN 6'-8" IN HEIGHT. PROJECT MANAGER OF ALL REVISIONS TO THE DRAWINGS AND
<br /> • DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND CHANGES WITH THE SCOPE OF WORK OR SCHEDULE REQUIRED BY
<br /> SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE DOORWAY GOVERNING AGENCIES, FIELD CONDITIONS OR BANK OF AMERICA Issue
<br /> IS NOT LESS THAN 32". PERSONNEL REGARDLESS OF EXTENT. ALL REVISIONS TO BE IN
<br /> � 12. WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE WRITING AS CHANGE ORDERS AND APPROVED PRIOR TO STARTING # Issue Date Issue Descriptio�n
<br /> DOORS SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING WIDTH WORK.
<br /> OF 32" WITH THE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES 13. CONTRACTOR TO PROVIDE EQUIPMENT TO ENSURE LIFE SAFETY OF 1 08/04/17 ISSUE FOR PERMIT
<br /> FROM ITS CLOSED POSITION. PUBLIC, TENANTS AND WORKERS AS REQUIRED BY FEDERAL,
<br /> 13. IDENTIFY ACCESSIBLE ENTRANCES WITH AT LEAST ONE STANDARD STATE AND LOCAL CODES THROUGHOUT CONSTRUCTION. z`�'�
<br /> ,.�
<br /> SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PROTECT
<br /> VISIBLE FROM APPROACHING PEDESTRIAN WAYS. PEDESTRIANS.
<br /> 14. THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR 14. CONTRACTOR TO VERIFY EXISTING STRUCTURAL CONDITIONS AND
<br /> • PASSAGE DOOR SHALL BE LEVEL AND CLEAR. THE LEVEL AND REQUIREMENTS OF NEW CONSTRUCTION PRIOR TO START OF
<br /> CLEAR RAEA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR WORK. CONTRACTOR SHALL FURNISH ADEQUATE SHORING,
<br /> SWING OF AT LEAST 60" AND THE LENGTH OPPOSITE THE DIRECTION BRACING, ETC. AS REWIRED TO SAFELY EXECUTE ALL WORK AND
<br /> � OF DOOR SWING OF 48" AS MEASURED AT RIGHT ANGLES TO THE SHALL BE FULLY RESPONSIBLE FOR SAME, UNLESS SPECIFICALLY
<br /> PLANE OF THE DOOR IN ITS CLOSED POSITION. DETAILED IN THE DRAWINGS. CONTRACTOR SHALL PROVIDE
<br /> 15. FLOORS AND LANDINGS SHALL BE NOT MORE THAN 1/2" LOWER BLOCKING, BACKING, FRAMING, HANGERS, OR OTHER SUPPORTS AS
<br /> THAN THE THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL NECESSARY FOR ALL FIXTURES, EQUIPMENTS AND ALL OTHER
<br /> BETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A SLOPE NO ITEMS REQUIRING SAME.
<br /> GREATER THAN 1:2. 15. SITE AND BUILDING SHALL BE MAINTAWED IN A CLEAN, SAFE
<br /> � 16. TO ALERT THE VISUALLY IMPAIRED, MARK THE UPPER APPROACH MANNER, DIRTY/ NOISY WORK SHALL BE PERFORMED AT SUCH TIME
<br /> AND THE LOWER TREAD OF EACH INTERIOR STAIR WITH A STRIP OF AS DIRECTED PER THE OWNER AND/OR CITY WHEN THE WORK
<br /> • CLEARLY CONTRASTING COLOR AT LEAST 2" WIDE, PLACED VARIOUS SECTIONS ARE COMPLETED, AND AT OTHER TIMES AS
<br /> PARALLEL TO AN NOT MORE THAN 1" FROM THE NOSE OF THE STEP DIRECTED BY BANK OF AMERICA, OR OWNER, ALL TRASH DEBRIS,
<br /> OR LANDING. THE STRIP SHALL BE OF A MATERIAL THAT IS AT SURPLUS MATERIAL, TOOLS AND EQUIPMENT TO BE REMOVED
<br /> � LEAST AS SLIP RESUSTANT AS THE OTHER TREADS OF THE STAIR. FROM THE SITE AND DISPOSED OF IN A LEGAL MANNER. LEAVE
<br /> }' 17. CENTER ELECTRICAL RECEPTACLE OUTLETS NOT LESS THAN 15" PREMISES IN A CONDITION ACCEPTABLE TO BANK OF AMERICA, OR
<br /> � ABOVE THE FLOOR OR WORKING PLATFORM. OWNER.
<br /> � 16. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE.
<br /> L WHERE EXISTING CONSTRUCTION, FINISHES OR EQUIPMENT IS
<br /> � DAMAGED BY WORK IN THIS CONTRACT, THEY SHALL BE PATCHED,
<br /> � REPAIRED OR REPLACED AS REQUIRED TO MATCH EXISTING, BY
<br /> � TRADE WHOSE WORK IS DAMAGED AT NO COST TO BANK OF
<br /> , � AMERICA.
<br /> � 17. LOCATION AND ELEVATION OF ALL WORK TO BE CONSTRUCTED ARE
<br /> Q� SHOWN ON DRAWINGS AND UNLESS DISCREPANCIES ARE BROUGHT
<br /> � �a
<br /> TO THE ATTENTION OF THE ARCHITECT PRIOR TO CONSTRUCTION,
<br /> � THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE PROPER SeallSignature
<br /> m LOCATION AND ELEVATIONS AS SHOWN AND INTENDED.
<br /> ��
<br />. r � � � � � . � . . .
<br /> �� ����
<br /> ������ ��
<br /> � � �������
<br /> �
<br /> ♦ � ���.< �� � �,��. �*����.. ,� �`., ...�� w.., � ._..,
<br /> ,i�, �. . � ,;�� ..
<br /> ,�,
<br /> � .,,... [ �r�,t� �. ��+.���
<br /> N �° �y �,g
<br /> � ���k � �� ���i t�d'���
<br /> , W
<br /> QI
<br /> 0
<br /> Q
<br /> v Project Name
<br /> m ADA UPGRADE
<br /> ��
<br /> cfl
<br /> 0
<br /> � Project Number
<br /> • `� 33.1546.065
<br /> cYi
<br /> M
<br /> �
<br /> N
<br /> N
<br /> , �
<br /> N
<br /> � Description
<br /> a� GENERAL NOTES
<br /> �
<br /> 0
<br /> �
<br /> a�
<br /> �
<br /> �
<br /> ca e
<br /> a...
<br /> ��
<br /> �
<br /> �
<br /> �
<br /> �
<br /> . �
<br /> U
<br /> N
<br /> .O
<br /> �
<br /> � AO0 . 10
<br /> �
<br /> �
<br /> L
<br /> �
<br /> �
<br /> �
<br /> ' �
<br /> � O 2016 Gensler
<br /> �
<br /> �
<br />
|