My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4201 RUCKER AVE COMMUNITY HEALTH CENTER 2019-04-10
>
Address Records
>
RUCKER AVE
>
4201
>
COMMUNITY HEALTH CENTER
>
4201 RUCKER AVE COMMUNITY HEALTH CENTER 2019-04-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2019 9:26:24 AM
Creation date
3/27/2018 12:05:11 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
4201
Tenant Name
COMMUNITY HEALTH CENTER
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
305
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
\IL) <br /> AwARCHITECTURE <br /> SPACE PLANNING <br /> architectural werks,inc. INTERIOR DESIGN <br /> July 11th, 2017 <br /> City of Everett Building Plans Examiner D kC7OVErr) <br /> Public Services Department <br /> 3200 Cedar Street JUL 14 2017 _J <br /> Everett, WA 98201 <br /> CITY OF EVERETT <br /> RE: Plan Check Number: B1705-065 Permit Services <br /> Dear Plan Reviewers, <br /> Engineering Public Services Department General Corrections Notice#1: <br /> Date:June 29th, 2017 <br /> Associate Engineer Plans Examiner:James Bronder, PE <br /> Phone: (425) 257-8810 <br /> Corrections: <br /> 1. Exit signs should be shown on the plans. Section 1013 <br /> Response: Exit signs indicated at stairway and egress doors shown on sheets A0.2, A0.3, and A0.4 <br /> per section 1013. <br /> 2. The doors in the exterior northern stairway should be shown as minimum 60-minute assemblies. <br /> Section 1027.6 &Table 716.5 <br /> Response: Notes added to demolish door 113A and replace with a 60 minute fire rated door <br /> assembly with a small lite. Details and door schedule updated to reflect new door assembly. Notes <br /> added to verify that existing doors 239A and 319A are 60 minute fire rated doors, or replace them <br /> with new 60 minute fire rated doors. See sheets A2.0,A2.3,A2.4, A2.5, A6.2, and A9.1 <br /> 3. The glazed opening adjacent to door 113A is within a one-hour fire-barrier. It should be verified <br /> that the glazing is approved for such a location or replaced with minimum one-hour construction. <br /> Sections 1027.6 &716.2 <br /> Response: Notes added to demolish existing storefront glazing adjacent to door 113A, and replace <br /> it with a new 60 minute rated wall assembly as shown on sheet A2.0,A2.3, and A6.2. <br /> 4. Two-way communication devices should be shown at the elevator landings on each floor. Section <br /> 1009.8 <br /> Response: Notes added to verify existing elevator communication device for existing elevator <br /> exist, and to provide new two-way communication devices if non-existent. See sheets A0.2, A0.3, <br /> 11416 98th Avenue NEāSuite 200,Kirkland,WA 98033 P:425.823.2244 F:425.898.4722 W:www.awerks.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.