Laserfiche WebLink
BUILDING CODE 8. ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION 7. KEYED CONSTRUCTION JOINTS SHALL BE USED IN ALL <br /> 2012 INTERNATIONAL BUILDING CODE WITH 5#8" MINIMUM DIAMETER BOLTS SPACED AT A MAXIMUM CASES. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY A <br /> OF 48" ON CENTER. BOLTS MUST BE EMBEDDED A MINIMUM CLEANED AND ALL LAITANCE SHALL BE REMOVED. ALL <br /> FLOOR LOAD OF 7" INTO CONCRETE OR MASONRY. SEE PLANS AND VERTICAL JOINTS SHALL BE THOROUGHLY WETTED AND <- <br /> DEAD LOAD : 12 psf DETAILS FOR SPECIFIC REQUIREMENTS WHERE APPLICABLE. SLUSHED WITH A COAT OF NEAT CEMENT IMMEDIATELY BEFORE E� <br /> LIVE LOAD: 40 psf PLACING NEW CONCRETE. ` <br /> 9. RIM JOIST IS TO BE 11#4" LSL MINIMUM. 8. SUBMIT LOCATION OF POUR JOINTS PRIOR TO PLACEMENT. <br /> ROOF LOAD POUR JOINTS SHALL BE LOCATED TO MINIMIZE EFFECTS OF <br /> DEAD LOAD: 15 sf 10. PROVIDE DOUBLE JOIST UNDER ALL PARALLEL PARTITION <br /> p WALLS AND SOLID BLOCKING UNDER PERPENDICULAR PARTITION SHRINKAGE AS WELL AS PLACED AT POINTS OF LOW STRESS. N <br /> FLAT ROOF SNOW LOAD:25 psf WALLS. MAXIMUM AREA OF POUR JOINTS IS 400 SF. +-, <br /> SNOW EXPOSURE FACTOR (Ce): 1.1 0 o <br /> SNOW LOAD IMPORTANCE FACTOR (Is): 1.0 11. CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO 9. MINIMUM CONCRETE COVERAGE OF REINFORCING STEEL FOR •CS Ln <br /> THERMAL FACTOR (Ct): 1.1 THESE DETAILS FORMED WORK SHALL BE AS FOLLOWS: o N <br /> WIND DESIGN DATA INTERIOR WALL: 3/4" (n w <br /> FOUNDATIONS EXTERIOR WALLS, EXPOSED TO WEATHER: 1/z U? >� <br /> 1. BASIC WIND SPEED: 85 MPH 1. THE FOUNDATION DESIGN IS BASED ON THE EXPOSED TO EARTH OR WEATHER (#5 OR SMALLER): 1'1h" Q <M x E <br /> 2. WIND IMPORTANCE FACTOR (1w): 1.0 RECOMMENDATION IN THE INTERNATIONAL BUILDING CODE *NOTE: CONCRETE CAST AGAINST GROUND SHALL HAVE 3" w I < o <br /> BUILDING CATEGORY: II TABLE 1804.2. FOUNDATION WORK SHALL BE PERFORMED IN MIN. COVERAGE C cc-"NH <br /> 3. WIND EXPOSURE: B ACCORDANCE WITH CHAPTER 18 OF THIS CODE. I w -ao <br /> 4. Kzt = 1.38 10. PIPES OTHER THAN ELECTRICAL CONDUITS SHALL NOT BEi <br /> 5. INTERNAL PRESSURE COEFFICIENT: NA 2. THE FOUNDATION DESIGN IS BASED ON THE FOLLOWING EMBEDDED IN STRUCTURAL CONCRETE EXCEPT WHERE Q0 o<p-\11-/) <br /> E <br /> 6. APPLICABLE WIND PRESSURE FOR VALUES: SPECIFICALLY APPROVED. n a-_so 3 <br /> COMPONENTS AND CLADDING: NA ALLOW. SOIL BEARING 2000 PSFN a; <br /> SOIL FRICTION .35 11. CONCRETE MIXES SHALL BE PROVIDED IN ACCORDANCE - co 0 <br /> SESIMIC DESIGN DATA EQUIV. FLUID PRESSURES WITH ACI 318 (WHEN STRENGTH DATA FROM TRIAL BATCHES 0 N w'ui <br /> 1. SEISMIC IMPORTANCE FACTOR: 1.0 ACTIVE PRESSURE* 55 PCF OR FIELD EXPERIENCE ARE NOT AVAILABLE). CN <br /> SEISMIC USE GROUP: I PASSIVE PRESSURE 250 PCF + <br /> • 2. SPECTRAL RESPONSE ACCELERATION (Ss):127.1% G CEMENT CONTENT U z <br /> 3. SITE CLASS: D (ASSUMED) 3. ALL FOOTINGS SHALL BE FOUNDED AT LEAST 18" BELOW SACKS PER O <br /> 4. SPECTRAL RESPONSE COEFFICIENTS (SDS): 84.7%G THE UNDISTURBED GROUNDSURFACE OR TO FROST DEPTH. LBS/CUBIC YARD a_ <br /> 5. SEISMIC DESIGN CATEGORY: D ALL FOOTINGS SHALL BE FOUNDED ON COMPACTED FILL OR CUBIC YARD U, <br /> 6. BASIC SEISMIC-FORCE-RESISTING SYSTEM: SHEARWALLS UNDISTURBED NATURAL GRADE UNLESS OTHERWISE NOTED. F'c (PSI) (MINIMUM) <br /> 7. DESIGN BASE SHEAR: SEE CALCULATIONS (MINIMUM) <br /> 8. SEISMIC RESPONSE COEFFICIENT (Cs): 091. 4. COMPACTION: MATERIAL FOR FILLING AND BACKFILLING 2500 (no special inspection) 470 <br /> 9. RESPONSE MODIFICATION FACTOR (R): 6.5 SHALL CONSIST OF THE EXCAVATED MATERIAL AND/OR 5 <br /> 10. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE IMPORTED BORROW AND SHALL BE FREE OF ORGANIC MATTER, SEE NOTE A <br /> PROCEDURE TRASH, LUMBER, OR OTHER DEBRIS. ALL WALLS SHALL BE 3000 517 W <br /> ADEQUATELY BRACED PRIOR TO BACKFILLING. FILL AND <br /> FRAMING LUMBER BACKFILL SHALL BE DEPOSITED IN LAYERS NOT TO EXCEED 8 5'1 l O <br /> CN <br /> 1. FRAMING LUMBER SHALL BE HEM-FIR NO. 2. GRADES ARE <br /> INCHES THICK, PROPERLY MOISTENED TO APPROXIMATE MIXES SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" I I I Q CO <br /> TYPICAL UNLESS OTHERWISE NOTED ON PLANS. LUMBER TO OPTIMUM REQUIREMENTS AND THOROUGHLY ROLLED OR <br /> BE GRADE MARKED PER WCLIB SPECIFICATIONS. COMPACTED WITH APPROVED EQUIPMENT IN SUCH A MANNER OR LESS. NO MORE THAN A 1" PLUS TOLERANCE SHALL BE <br /> AND EXTENT AS TO PRODUCE A RELATIVE COMPACTION OF ALLOWED. - n <br /> 2. STRUCTURAL SHEATHING SHALL BE APA RATED PLYWOOD, 90% OF MAXIMUM POSSIBLE DENSITY AS DETERMINED BY ASTM Si / < <br /> EXPOSURE 1 SHEATHING CONFORMING TO EITHER COMMERCIAL D1557. HAND TAMPERS SHALL WEIGH AT LEAST 50 POUNDS A) WHERE SPECIAL INSPECTION IS NOT REQUIRED UNDER Q <br /> STANDARDS P51-83, APA PRP 108, OR VOLUNTARY PRODUCT EACH AND SHALL HAVE A FACE AREA NOT IN EXCESS OF 64 SECTION 1704.4 OF THE I.B.C., CONCRETE SHALL HAVE A n <br /> STANDARD PSE-92. PROVIDE A MINIMUM OF 3/s" EDGE SQUARE INCHES. HAND TAMPERS MAY BE OPERATED EITHER MINIMUM CEMENT CONTENT OF 5 SACKS PER CUBIC YARD OF n ^ <br /> DISTANCE ON ALL NAILS AND Ya" EXPANSION JOINT BETWEEN MANUALLY OR MECHANICALLY AND SHALL BE USED WHERE CONCRETE. \ I__ <br /> ALL PANEL EDGES. MINIMUM SHEATHING REQUIREMENTS ARE AS LARGER POWER DRIVEN COMPACTION EQUIPMENT CANNOT BE I i I I- <br /> FOLLOWS: USED. STRUCTURAL FILL OVER 12" DEEP SHALL COMPLY WITH B) DESIGN MIX (OTHER THAN AS SPECIFIED IN THIS TABLE) <br /> �g„ A GEOTECHNICAL REPORT. SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TWO WEEKS (Yl W <br /> ROOF SHEATHING TO BE E INT-APA RATED PLYWOOD 0, PRIOR TO FIRST USE Q (Y <br /> P.I. 40/20. NAIL WITH 8d NAILS AT 6" ON CENTER AT CONCRETE • ry I I I <br /> PANEL EDGES AND 12" ON CENTER AT INTERMEDIATE 1. ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REINFORCING STEEL Li MD > <br /> MEMBERS. REGULAR WEIGHT HARD ROCK TYPE (150 PCF) AGGREGATES 1. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 -) I i I <br /> SHALL CONFORM TO ASTM C33 WITH PROVEN SHRINKAGE GRADE 60 (fy = 60 KSI) FOR BAR SIZES NO. 5 & LARGER, <br /> SUB FLOORING TO BE 3/4" TONGUE AND GROOVE C-D CHARACTERISTICS OF LESS THAN 0.05%. GRADE 40 (fy = 40 KSI) FOR NO. 3 AND NO. 4 BARS. <br /> INT-APA RATED PLYWOOD OR OSB WITH EXTERIOR GLUE, <br /> P.I. 48/24. GLUE AND NAIL WITH 10d NAILS AT 6" ON 2. ALL CONCRETE DESIGN IS BASED ON A 28 DAY 2. ALL REINFORCING STEEL SHALL BE LAPPED AS NOTED ON • <br /> CENTER AT PANEL EDGES AND 12" ON CENTER AT COMPRESSIVE STRENGTH (f'c) OF 2500 PSI. WHERE 3000 PSI THE PLANS. WHERE LAP OR SPLICE LOCATIONS ARE NOT <br /> INTERMEDIATE MEMBERS, (SEE BASEMENT WALL CONCRETE IS REQUIRED BY THE BUILDING DEPARTMENT FOR SPECIFICALLY INDICATED ON THE CONSTRUCTION DOCUMENTS, <br /> • SCHEDULE). WEATHERING PURPOSES ONLY, NO SPECIAL INSPECTION IS LAPS AND/OR SPLICES SHALL BE 42 BAR DIA AND BE WELL <br /> REQUIRED. STAGGERED. <br /> 3. NAILING SHALL CONFORM TO TABLE 2304.9.1 OF THE <br /> INTERNATIONAL BUILDING CODE UNLESS NOTED OTHERWISE. 3. CEMENT SHALL CONFORM TO ASTM C150, TYPE I, CSA 3. COMPLETE REINFORCING PLACEMENT DRAWINGS PREPARED IN <br /> USE COMMON NAILS THROUGHOUT UNLESS NOTED OTHERWISE. NORMAL. ACCORDANCE WITH ACI 315 SHALL BE REVIEWED BY THE <br /> ENGINEER AND AVAILABLE ON THE JOB SITE PRIOR TO THE <br /> 4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED 4. MAXIMUM SLUMP SHALL NOT EXCEED 4 INCHES IN PLACING OF CONCRETE. <br /> UNLESS SPECIFICALLY DETAILED OR APPROVED IN WRITING BY FLATWORK. Drawn By: CCC <br /> THE STRUCTURAL ENGINEER. 4. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A82 AND Checked By: CCC <br /> 5. PLACEMENT OF CONCRETE SHALL BE IN CONFORMANCE WITH A185 AND SHALL BE 6x6 W2.1/W2.1 UNLESS OTHERWISE Date: 11-26-14 <br /> 5. PROVIDE PROPERLY SIZED WASHERS UNDER HEADS AND ACI 301. NOTED. LAP REINFORCEMENT 6" MINIMUM. <br /> NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. SDA JOB NO. <br /> 6. CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION 5. ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS 7L21 <br /> 6. PROVIDE 3"x3"x0.229" WASHERS AT ALL ANCHOR BOLTS. FOR A MINIMUM OF FIVE (5) DAYS AFTER PLACEMENT. SHALL BE SECURELY TIED IN PLACE BEFORE CONCRETE IS <br /> ALTERNATE METHODS WILL BE APPROVED IF SATISFACTORY POURED. SLAB ON GRADE REINFORCEMENT SHALL BE PLACED <br /> ' STRUCTURAL <br /> 7. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS PERFORMANCE CAN BE ASSURED. AT MID-DEPTH OF SLAB AND SHALL BE HELD SECURELY IN DETAILS) " UNLESS NOTED OTHERWISE. LAG BOLT PILOT HOLES SHALL PLACE WITH MECHANICAL DEVICES DURING PLACING OF THE <br /> BE PRE-DRILLED TO 60% OF THE NOMINAL DIAMETER OF THE CONCRETE. S- 0 / /fl <br /> LAG BOLT UNLESS NOTED OTHERWISE. <br />