PRE-FABRI ED BUILDING DESIGN - FOUNDATION_CULATIONS <br /> BRIGGS ENGINEERING PO BOX 140537,GARDEN CITY, ID 83714-0537 IBC-2015 <br /> CLIENT Pacific Mobile DEALER: Pacific Mobile Structures, Inc. Criteria 25psf-RLL,40psf-FLL,110mph, Exp <br /> C, Cat-D, Ss=1.5, Fp=1500 psf <br /> Date: 25-Mar-17 EST#PO# E17040 Location: KCDA Standards <br /> 28x32 MODULAR COPYRIGHT <br /> Project#: 201701 1 WC-1 05.2-1 FDN-Classroom w/(2) BEI 2017 State(s): ID-OR-WA Varies <br /> Floor Joist Spans <br /> II. FOUNDATION DESIGN <br /> A. Foundation Components <br /> Option A Individual Bearing Pads-Bearing Pads Column Pads <br /> Width,wbp= 16 inches 16 inches <br /> Length, Ibp= 16 inches 16 inches <br /> Surface Support Depth: Conc,Asph&Base 4 inches, Required <br /> Equivalent Bearing Area at Soil, BA= 400 Sq. Inches 384 Sq Inches <br /> IBC-T.18.4.2 Allowable Soil Bearing Pressure, [Class 4] Q= 1500 psf. To Be Verified By Others <br /> Option B Perimeter Support Width 0 inches <br /> Allowable Load, Pbp=(BA)/144*Q= 4167 pounds 4000 pounds <br /> Anchors-'Minuteman'Soil Anchors <br /> Ultimate Uplift Anchor Capacity,AnchU= 4725 lbs. <br /> Ultimate Lateral Anchor Capacity,AnchL= 3341 lbs. 45 Degree from Horizontal <br /> B. Exterior Pads(Around Perimeter) <br /> Floor and Roof Loads: <br /> Exterior Pads Required, Epr= 1 pad <br /> Allowable Load, Pfla= 4167 lbs. From Computer <br /> Calculations, max. span <br /> Perimeter Support Bearing Pressure, (Skirting) 0 psf-OK! <br /> Classroom Exterior Uniform Floor Load, 538 plf 7.76 ft. 6.00 ft. <br /> Classroom Use: Perimeter Pads W/(7) 16-inch x 16-inch pad @ 6-ft o.c.exterior supports. <br /> C. Interior Pads(Floor Loads Only-Mateline Supports) <br /> Floor Loads: <br /> Interior Pads Required, Ipr= 1 pad From Computer <br /> Calculations, max. span <br /> Allowable Load, Pfla= 4167 lbs. <br /> Classroom Interior Uniform Floor Load, 350 plf 11.90 ft. 8.00 ft. <br /> Classroom Use: (5)16-inch x 16-inch Pads @ 8-ft o.c.interior supports. <br /> D.Column Pads(Roof Loads Only) <br /> Roof Loads: <br /> Column Pads Required, Cpr= 1 pads <br /> Allowable Load, Prla= 4000 lbs. <br /> Mateline Roof Beams Uniform Roof Load,mbrl=(RLL+RDL)*MW= 518 lb/ft. <br /> Effective Mateline Beam Span, Mps=Pfla/mbrl= 7.72 ft. <br /> Use: (1)16-inch x 16-inch pads for every 7.72-ft effective Mateline Beam Span. <br /> Effective Interior Roof Beam Span= 0 ft 0 PADS REQ'D <br /> Effective.Interior Roof Beam Span= 16 ft 3 PADS REQ'D <br /> v8f1� 201701.05,KCDA STD FDN-Calcs.xlsx PRINTED-3/25/2017 <br />