t \- Rcc <br /> Gl EO }ESIG N? FIELD REPO TT <br /> ,t <br /> Project Name: Everett River Front-Simpson Report: 045 <br /> GeoDesign#: 1 Polygon-127-03 Date: 05/26/2017 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> PW 1505-005 <br /> \ O • S <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) Weather Clear, 70's <br /> Ron Bowen(Polygon) Eddy Stevens(Polygon) Arrival/Departure: 1200/1230 <br /> Distribution: _ <br /> Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> Paul McKee(City of Everett) Dave Foster(City of Everett) Prepared By: Ben Weinberg <br /> Attachments: m Site Plan(s) m Density Test Summary Signature: 2'w <br /> Installation Records 0 Other Reviewed By: A% <br /> PURPOSE of VISIT: GeoDesign representative, Ben Weinberg,was on-site part time at the request of Craig with DDS to <br /> observe the foundation subgrade for Lots 259 and 260. <br /> SUMMARY of OBSERVATIONS: <br /> LOT 259: <br /> Today, GeoDesign noted that DDS was in the process of backfilling the lot area with 2-inch clean crushed railroad ballast to <br /> plan bottom of footing. <br /> LOT 260: <br /> Previously, GeoDesign noted that the west 1/4 of the lot area could be probed 6 to 12 inches using a 1/2 inch diameter soil <br /> probe and recommended that the material be over-excavated down to firm and unyielding underlying material. Today, <br /> GeoDesign noted that DDS over-excavated the above-mentioned area down 6 inches to 1.5 feet. Material exposed at the <br /> base of the over-excavated area consisted of a gray-brown silty SAND with gravel which could be probed less than 1 inch <br /> using a 1/2 inch diameter soil probe.GeoDesign notified Craig with DDS that the area was suitable for placement of backfill <br /> material. <br /> GeoDesign noted that DDS began placement of a 2-inch clean crushed railroad ballast material today. <br /> A summary of our observations and density tests can be found in the attached Figure 1. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services.We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project irrespective of the presence of our representative.Our work does not Include supervision or direction of the contractor,the contractor's employees <br /> or agents. Our firm is not responsible for site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations.The report can only be considered <br /> final upon review of the GeoDesign project manager,as Indicated by Initials In the"Reviewed By"section. <br /> 10700 Meridian Avenue North,Suite 402 I Seattle,WA 98133 I 206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98402 I 253.203.0095 <br />