My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
905 80TH ST SW MTORRES AMERICA 2018-09-18
>
Address Records
>
80TH ST SW
>
905
>
MTORRES AMERICA
>
905 80TH ST SW MTORRES AMERICA 2018-09-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2018 8:45:35 AM
Creation date
3/30/2018 2:31:54 PM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
905
Tenant Name
MTORRES AMERICA
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
428
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Drawing No. Rev. <br /> ENGINEERING JUDGMENT FIRESTOP DETAIL NS06917021 - <br /> Cold Smoke Seal <br /> 0 <br /> o.. <br /> 0' <br /> 0 <br /> a a hill • � <br /> • ll ll 4 A . <br /> . L1 <br /> 0 <br /> .�C <br /> 1. Floor Assembly (1 Hr) -Min 2"thick concrete over metal deck(max 3"deep flutes) floor assembly. <br /> 2. Penetrants -Annular space is min 0"9point contact)to max 2". Any combination of the following may be installed: <br /> A. Two (or fewer) max 3/4"diam (or smaller) copper with max 3/4"thick AB/PVC pipe insulation. <br /> B. Two (or fewer) max 3/4"diam (or smaller) copper pipes. <br /> C. Two (or fewer) max 4 pair No. 18 AWG thermostat cable. • <br /> 3. Packing Material -Min 4 pcf density mineral wool batt insulation tightly packed and installed within opening to a <br /> min 1-1/2"depth, recessed from top surface of floor to accommodate for the required depth of sealant. <br /> 4. Sealant-SpecSeal®LCI Sealant applied to completely cover mineral wool to a min 1/2"depth, flush with top <br /> surface of floor. Sealant applied at point contact locations as a min 1/2"diam bead. <br /> THIS DESIGN REPRESENTS A FIRESTOP SYSTEM EXPECTED TO PASS THE STATED RATINGS IF TESTED <br /> Project: Mtorres Signature: SO ste-AJm-8084 Reference: <br /> Project Address: Everett,WA 98201 <br /> Designed by: Gary Mason <br /> Contractor:Mechanical FirestopServices Scale: Date: Based on testing to ASTM E814/UL 1479:Standard for Fire <br /> N.T.S. 3/10/2017 PAGE 1 OF 1 Tests of Penetration Firestops <br /> All statements,technical information,and recommendations contained herein are based <br /> Specified Technologies Inc. upon tests we believe to be accurate;however since the conditions of use and application <br /> are beyond our control,STI shall not be liable for any damage,direct or consequential, <br /> ys� 110!vane Way•Somevllle,NJ0187$USA•Toll Free:100.992.1110•T1+1901.52/.1100 resulting from the use of this material or design.STI'ssole warranty shall be to refund or <br /> . F:*1808237.8415•Eteeheery@aGflreetop.eom•wwwWflrestopeom replace materials found to be defective. <br /> s*f <br />
The URL can be used to link to this page
Your browser does not support the video tag.