My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
225 N CABOT RD 2019-10-04
>
Address Records
>
N CABOT RD
>
225
>
225 N CABOT RD 2019-10-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/4/2019 11:22:01 AM
Creation date
4/4/2018 3:07:55 PM
Metadata
Fields
Template:
Address Document
Street Name
N CABOT RD
Street Number
225
Notes
"Unit B" is 6832 Beverly Ln, "Unit A" is this address
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size:Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Unit A Glenn Morgan Construction <br /> 6832 Beverly Ln 6832 Beverly Ln <br /> Everett,WA 98203 425-344-4872 <br /> Heating System Type: O All Other Systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Instructions - Design Temperature Difference(AT) 49 <br /> Everett Paine AFB J <br /> AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> instructio is Conditioned Floor Area(sq ft) 1,949 <br /> Average Ceiling Height Conditioned Volume <br /> instructions Average Ceiling Height(ft) 8.5 16,567 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> 0.30 212 63.60 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions I R-49 w , 0.026 1,019 26.49 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions No selection <br /> Select R Value --- <br /> ^'•=-'s <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions 0.056 2,092 117.15 <br /> j R-21 Intermediate 1, <br /> Floors U-Factor X Area UA <br /> Instructions No selection 1,019 <br /> Select R Value w I <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions _. _._ _ ! - <br /> Select R value .� J No selection --- <br /> Slab Below Grade(see Figure 1) F-Factor X Length UA <br /> Instructions <br /> Select conditioningNo selection <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> IllStillCt1011ti <br /> Select R Value .,..V..� No selection <br /> J --- <br /> Location of Ducts <br /> Instructions Duct Leakage Coefficient <br /> Unconditioned Space _ <br /> 1.10 <br /> • <br /> Sum of UA 207.25 <br /> Envelope Heat Load 10,155 Btu/Hour <br /> Figure 1. Sum of DA X AT <br /> Air Leakage Heat Load 8,767 Btu/Hour <br /> Volume 0.6X AT X.018 <br /> Above Grade Building Design Heat Load 18,922 Btu/Hour <br /> '-' Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 20,814 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 29,140 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.