My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
225 N CABOT RD 2019-10-04
>
Address Records
>
N CABOT RD
>
225
>
225 N CABOT RD 2019-10-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/4/2019 11:22:01 AM
Creation date
4/4/2018 3:07:55 PM
Metadata
Fields
Template:
Address Document
Street Name
N CABOT RD
Street Number
225
Notes
"Unit B" is 6832 Beverly Ln, "Unit A" is this address
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table R402.1.1 Footnotes I <br /> For SI: 1 foot.=304.8 mm,ci.=continuous insulation,int.=intermediate framing. <br /> a R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity which <br /> is less than the label or design thickness of the insulation,the compressed R-value of the insulation from <br /> Appendix Table A101.4 shall not be less than the R-value specified in the table. <br /> b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. <br /> `"10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall,or R-15 on the continuous <br /> insulation on the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the <br /> basement wall at the interior of the basement wall. "10/15/21.+TB"shall be permitted to be met with R-13 <br /> cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or <br /> exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R- <br /> 13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and <br /> basement wall. <br /> d R-10 continuous insulation is required under heated slab on grade floors.See R402.2.9.1. <br /> e There are no SHGC requirements in the Marine Zone. <br /> Reserved. <br /> g Reserved. <br /> n Reserved. <br /> The second R-value applies when more than half the insulation is on the interior of the mass wall. <br /> Reserved. <br /> k For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38. <br /> Reserved. <br /> m Int. (intermediate framing)denotes standard framing 16 inches on center with headers insulated with a <br /> minimum of R-10 insulation. <br /> Table R402.1.3 Footnote <br /> a Nonfenestration U-factors shall be obtained from measurement,calculation or an approved source or as <br /> specified in Section R402.1.3. <br />
The URL can be used to link to this page
Your browser does not support the video tag.