Laserfiche WebLink
WOOCIWOPI(S®Sh@aPW1IIS 17134.1 Rucker Duplex Lateral-UPDATED FEB <br /> 2018.wsw Feb.11,2018 12:21:19 <br /> SHEARLINE,WALL and OPENING DIMENSIONS(continued) <br /> Wall G-1 Seg 2 34.00 0.00 4.00 4.00 4.00 2.00 - <br /> Wall G-2 NSW 34.00 4.00 6.00 2.00 0.00 4.00 - <br /> Wall G-3 Seg 2 34.00 6.00 10.00 4.00 4.00 2.00 - <br /> Wall G-4 Seg 2 34.00 30.00 34.00 4.00 4.00 2.00 - <br /> Wall G-5 NSW 34.00 34.00 36.00 2.00 0.00 4.00 - <br /> Wall G-6 Seg 2 34.00 36.00 40.00 4.00 4.00 2.00 - <br /> Level2 <br /> Line G 3 34.00 10.00 30.00 20.00 14.00 - 9.00 <br /> Wall G-1 Seg 3 34.00 10.00 14.00 4.00 4.00 2.25 - <br /> Wall G-2 NSW 34.00 14.00 17.00 3.00 0.00 3.00 - <br /> Wall G-3 Seg 3 34.00 17.00 23.00 6.00 6.00 1.50 - <br /> Wall G-4 NSW 34.00 23.00 26.00 3.00 0.00 3.00 - <br /> Wall G-5 Seg 3 34.00 26.00 30.00 4.00 4.00 2.25 - <br /> Line H <br /> Level 3 <br /> Line H 36.00 10.00 30.00 20.00 0.00 - 8.00 <br /> Wall H-1 NSW 36.00 10.00 13.50 3.50 0.00 1.00 - <br /> Wall H-2 NSW 36.00 13.50 26.50 13.00 0.00 1.00 - <br /> Wall H-3 NSW 36.00 26.50 30.00 3.50 0.00 1.00 - <br /> Legend: <br /> Type-Seg=segmented,Prf=perforated,NSW=non-shearwall <br /> Location-Dimension perpendicular to wall <br /> FHS-Length of full-height sheathing used to resist shear force.For perforated walls,it is based on the factored segments U defined in SDPWS <br /> 4.3.4.3 <br /> Aspect Ratio-Ratio of wall height to segment length(Wbs) <br /> Wall Group-Wall design group defined in Sheathing and Framing Materials tables,where it shows associated Standard Wall <br /> • <br /> 6 <br />