My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3317 RUCKER AVE C D 2020-07-15
>
Address Records
>
RUCKER AVE
>
3317
>
3317 RUCKER AVE C D 2020-07-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2020 2:17:51 PM
Creation date
4/5/2018 9:25:53 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3317
Unit
C D
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
161
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WoodWorks®$fl@arw u s 17134.1 Rucker Duplex Lateral-UPDATED FEB <br /> 2018.wsw Feb.11,2018 12:21:19 <br /> HOLD-DOWN DESIGN(flexible seismic design,continued) <br /> A-3 L End 9.63 0.00 1368 1481 306 193 CS16 - 1.0 1705 0.11 <br /> A-3 R End 13.13 0.00 1368 531 110 947 CS16 - 1.0 1705 0.56 <br /> A-4 L End 13.38 0.00 1288 <br /> A-4 R End 26.63 0.00 1288 <br /> A-5 L End 26.88 0.00 1368 531 110 947 CS16 - 1.0 1705 0.56 <br /> A-5 R End 30.38 0.00 1368 1481 306 193 CS16 - 1.0 1705 0.11 <br /> A-6 L End 30.63 0.00 243 <br /> A-6 R End 35.88 0.00 198 <br /> A-7 L End 36.13 0.00 1452 144 30 1338 CS16 - 1.0 1705 0.78 <br /> A-7 R End 39.88 0.00 1452 144 30 1338 CS16 - 1.0 1705 0.78 <br /> Line G <br /> G-1 L End 0.12 34.00 1670 115 24 1578 CS16 - 1.0 1705 0.93 <br /> G-1 R End 3.88 34.00 1670 115 24 1578 CS16 - 1.0 1705 0.93 <br /> G-2 L End 4.13 34.00 58 <br /> G-2 R End 5.88 34.00 58 <br /> G-3 L End 6.13 34.00 1670 115 24 1578 CS16 - 1.0 1705 0.93 <br /> G-3 R End 9.87 34.00 1670 1411 292 550 CS16 - 1.0 1705 0.32 <br /> G-4 L End 30.13 34.00 1670 1411 292 550 CS16 - 1.0 1705 0.32 <br /> G-4 R End 33.87 34.00 1670 115 24 1578 CS16 - 1.0 1705 0.93 <br /> G-5 L End 34.13 34.00 58 <br /> G-5 R End 35.88 34.00 58 <br /> G-6 L End 36.13 34.00 1670 115 24 1578 CS16 - 1.0 1705 0.93 <br /> G-6 R End 39.88 . 34.00 1670 115 24 1578 CS16 - 1.0 1705 0.93 <br /> Legend: <br /> Line-Wall:. <br /> At wall or opening-Shearline and wall number <br /> At vertical element-Shearline <br /> Posit'n- Position of stud that hold-down is attached to: <br /> V Elem- Vertical element:column or strengthened studs required where not at wall end or opening <br /> L or R End-At left or right wall end <br /> L or R Op n-At left or right side of opening n <br /> Location-Co-ordinates in Plan View <br /> Hold-down Forces: <br /> Shear-Seismic shear overturning component,factored for ASD by 0.7.For perforated walls,T from SDPWS 4.3-8 is used <br /> Dead-Dead load resisting component,factored for ASD by 0.60 <br /> Ev-Vertical seismic load effect from ASCE 712.4.2.2=-0.2Sds x ASD seismic factor x unfactored D=0.207 x factored D.Refer to Seismic <br /> Information table for more details. <br /> Cmb'd-Sum of ASD-factored overturning,dead and vertical seismic forces.May also include the uplift force t for perforated walls from SDPWS <br /> 4.3.6.2.1 when openings are staggered. <br /> Hold-down-Device used from hold-down database <br /> Cap-Allowable ASD tension load <br /> Crit.Resp.-Critical Response=Combined ASD force/Allowable ASD tension load <br /> Notes: <br /> ^WARNING-This hold-down does not have design capacities for the thickness of end studs selected,so additional jack studs or blocking required <br /> Shear overturning force Is horizontal seismic load effect Eh from ASCE 7 12.4.2. <br /> Uses load combination 8 from ASCE 7 2.4.1=0.6D+0.7(Eh-Ev). <br /> Anchor bolts must have minimum 0.229"x 3"x 3"steel plate washers,conforming to specifications in SDPWS 4.3.6.4.3 and 4.4.1.6. <br /> Refer to Shear Results table for factor Co,and shearline dimensions table for the sum of Li,used to calculate tension force T for perforated walls <br /> from SDPWS 4.3-9. <br /> Shearwalls does not check for either plan or vertical structural irregularities. <br /> 45 <br />
The URL can be used to link to this page
Your browser does not support the video tag.