Component Performance Path, pg. 2 ENV-UA <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: OLYMPIC PARK APARTMENTS-LEASE OFFICE Date 06/29/2016 <br /> Fenestration Area as%gross above-grade wall area 26.0% Max.Target: 30.0% For Building Department Use <br /> Skylight Area as%gross roof area Max.Target: 3.0% <br /> Building Component Proposed UA Target UA <br /> Ins.R Plan/Detail# F-factor Source&Table#8 F-factor x Perimeter =UA(U x A) F-factor x Perimeter= UA(U x A) <br /> R= 0.540 <br /> 3 R= Slab-On Grade F-0.54 <br /> 0`1 R= <br /> R=10 0.550 <br /> R= Heated Slab-On-Grade F-0.55 , <br /> = R= <br /> Schedule ID U-factor Source9'10 U-factor x Area(A) =UA(U x A) U-factor x Area(A)= UA(U x A) <br /> Storefront entry doors 1.098 21 23.1 0.37 1 49 18.1 <br /> Insulated Hollow Metal 0.067 28 1.9 Opaque Swing Doors U-0.37, <br /> 2 co <br /> 0 <br /> 0 <br /> D 0.34 <br /> Opaque rollup&sliding U-0.34 <br /> 0.30 <br /> Non-Metal Frame �: 0.30' <br /> ca; <br /> o g Glass 0.25 618 152.6 0.38 618 234.8 <br /> Metal,:Frame,Fixed- U-0.38 ;,, <br /> o _ <br /> m <br /> 2 <br /> ii .• 0.40 <br /> 0 Metal Frame,Operable U-0.40 <br /> O ToCD0.60 <br /> Metal'Entrarnce Door U-0.60 <br /> m <br /> 0.50 <br /> m <br /> n <br /> All types i1-0.50 <br /> Y <br /> V) Q <br /> Area' UA Area' UA <br /> Page 2 Subtotal 667 178 667 253 <br /> TO COMPLY-The Proposed Total UA shall not Page 1 Subtotal 3656 155 3656 154 <br /> exceed the Target Total UA. Project Total 4323 332 4323 406 <br /> Component Performance Compliance (UA) UA COMPLIES <br /> Note 1-If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1,then Target Area Adjustment of all applicable envelope <br /> elements will be calculated automatically by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br /> Note 2-Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 3-Proposed CMU mass wall in non-Group R that meet Table C402.1.4 Footnote D requirements can enter the target U-value of 0.014 <br /> Note 4-For semi-heated spaces utilizing the wall insulation exception,enter Target Wall U-factors under Proposed Wall U-factors so exterior <br /> walls are neutral to the calculation. <br /> Note 5-Mass transfer slab edges must be covered with an assembly having an overal U-factor of 0.2. <br /> Note 6-Demising walls,doors,and vertical fenestration separating spaces with different degrees of space conditioning(unconditioned,semi-heated, <br /> fully conditioned)shall be included only on the ENV-UA form for the space with the greatest degree of space conditioning. <br /> Note 7-List Group R above grade mass walls here. List all other mass walls, Commercial and Group R,in the Opaque Walls-Above Grade section. <br /> Note 8 -Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 9 -Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 10-Fenestration assembly U-Factors shall be the manufacturer's NFRC product rating, which includes the glazing and frame, or shall be 2 <br /> the default value per Section C303.1.3. <br />
The URL can be used to link to this page
Your browser does not support the video tag.