GENERAL - YESNO <br /> Bathroom doors are easily and quickly openable from the outside when locked g. ❑ <br /> Carbon Monoxide alarms are installed as required in R315.1 on each level of the home. <br /> smoke alarms are instailea on ail levels ortne aweiiing,in eacn resident sleeping room,outside each separate <br /> sleeping area in the immediate vicinity of sleeping rooms(R314). AK. 0 <br /> Smoke and Carbon Monoxide alarms are installed In such a manner so that the audible warning may be heard in all xic. 0 <br /> parts of the dwelling upon activation of a single device. <br /> Access road and water supply meet local fire jurisdictional requirements. yiar ❑ <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not req 're tight grasping,pinching or twisting of the wrist(lever-type). El <br /> efoor <br /> R311.8 Ramps YES NO <br /> l. <br /> Inside Ramp N/A 0 CI <br /> R311.8.1 Maximum S of pe one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) ❑ ❑ <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes <br /> directions. 0 0 <br /> _ _ .. . . . . .. ____ -__ ____ -.._ <br /> outside Ramp 1 N/A 0 ( YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) A 0. <br /> R311.8.2 landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes 0 <br /> directions. <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.83.3. kli. 0 <br /> Guards below are depicted vertically as an example only.All Ramps must have Guards A. ❑ <br /> Handrail both sides <br /> I <br /> Guard --Less than 4" 34"-38" <br /> f IIS <br /> .Iilll <br /> 36"min ii( (( j <br /> 1i I l L_ t 3'x3'min <br /> landing <br /> 3'x 3'min � <br /> landing _ —• <br /> 3' -J One unit vertical in twelve units horizontal I''--3' -I <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br /> R311.2 Means of Egress • YES NO <br /> R311.2 Door must be side-hinged with min.width of 32 inches between face of door and stop.Height not less than 78 inches. AgL ❑ <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). 0 <br /> R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry 33Cs. 0 <br /> t4iithn It tIca of kare tnnl nr cnariai knnudarirrn Panrrirar4 oust tint avail karya nn nArlitinnal inrkinn r4aar3rac <br /> R311.7 Stairways I WAAL' YES NO <br /> R311.7.4.1 Riser Height:Max riser height shall be 7% inches(8 inches in structures built prior to July 1,2004) ❑ ❑ <br /> R311.7.4.2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures built prior to July 1,2004) 0 0 <br /> R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple 0 0 <br /> risers.Handrails shall be installed in accordance with R311.7.7.1—R311.7.7.4 <br /> Effective:2013 July 01 <br /> Updated:2013 June <br />
The URL can be used to link to this page
Your browser does not support the video tag.