Simple Heating System Size:Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Unit E3 Townhome Polygon Northwest <br /> Eclipse Jamie Aubrey <br /> Everett,Washington (425)586-7700 <br /> Heating System Type: O Forced Air Furnace 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> instructions .- - Design Temperature Difference(AT) 47 <br /> Everett 1C _ <br /> AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 1,560 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.5 13,260 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions 0.30 I 241 I 72.27 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> instructions I R I90.026 688 17.89 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> Instructions .. _.. _ -- <br /> No Vaulted Ceilings in this project. V J <br /> Above Grade Walls(see Figure 1) U-Factor Area UA <br /> Instructions R-27 —J �, l 0.056 I 1,801 I 100.86 <br /> Floors J U-Factor Area UA <br /> Instructions <br /> R-3o - I 0.029 430 12.47 <br /> � J <br /> Below Grade Walls(see Figure 1) U-Factor Area UA <br /> Instructions <br /> I __No Below Grade Walls m this project. <br /> l <br /> Slab Below Grade(see Figure 1) F-Factor Length UA <br /> Instructions <br /> j I No Slab Below Grade in this project --- <br /> ._. .. <br /> Slab on Grade(see Figure 1) J F-Factor Length UA <br /> Instructions <br /> R-to Perimeter <br /> 0.540 75 40.50 <br /> , . ) <br /> Location of Ducts <br /> Instructions ( <br /> --- Duct Leakage Coefficient <br /> _ - _ _ <br /> 1 [Conditioned Space - i J <br /> 1.00 <br /> Sum of UA 243.98 <br /> Envelope Heat Load 11,467 Btu/Hour <br /> Figure 1. Sum ofUAXAT <br /> Air Leakage Heat Load 6,731 Btu/Hour <br /> �.- VolumeX 0.6XATX.018 <br /> Above Grade Building Design Heat Load 18,198 Btu/Hour <br /> n-- Air Leakage+Envektpe Heat Loss <br /> Building and Duct Heat Load 18,198 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 25,477 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/01/ <br /> 79 <br />