• <br /> Simple Heating System Size:Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Unit E Townhome Polygon Northwest Company <br /> Eclipse Jamie Aubrey <br /> Everett,Wa (425)586-770D <br /> Heating System Type: lt Forced Air Furnace 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Instructions _._ Design Temperature Difference(AT) 47 <br /> Everett JC AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 1,163 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8,5, 9,886 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions 0.30 1 ' 38.13 <br /> Insulation <br /> AtticU-Factor X Area = UA <br /> jj <br /> _ <br /> t — 1 <br /> Instructions <br /> R-49 „ 0.026 579 ` 15.05 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> Instructions ( <br /> I No Vaulted Ceilings in this project <br /> L. <br /> Above Grade Walls(seeFigurel) U-Factor Area UA <br /> Instructions 0.056 590 33.04 <br /> ` <br /> 5-21 <br /> Floors U-Factor Area UA <br /> Instructions 4 R-30 0.029 53S 15.46 <br /> Below Grade Walls(see Figure 1) U-Factor Area UA <br /> Instructions <br /> No Below Grade Walls in this project. J -' <br /> Slab Below Grade(see Figure 1) F-Factor Length UA <br /> Instructions <br /> No Slab Below Grade in this project. y <br /> Slab on Grade(see Figure 1) F-Factor Length UA <br /> Instructions -- _— --- <br /> R 0.540 22 11.88 <br /> -10 Perimeter <br /> Location of Ducts <br /> Instructions _---- - <br /> -- Duct Leakage Coefficient <br /> !l I Conditioned Space <br /> 1.00 <br /> Sum of UA 113.56 <br /> Envelope Heat Load 5,337 Btu I Hour <br /> Figure 1. Sum of UAXtT <br /> Air Leakage Heat Load 5,018 Btu/Hour <br /> ,. _., VolumeX 0.6 XAT X.018 <br /> Above Grade Building Design Heat Load 10,355 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 10,355 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heal Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 14,497 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/01/13) <br />