My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3337 31ST DR 2019-01-11
>
Address Records
>
31ST DR
>
3337
>
3337 31ST DR 2019-01-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2019 2:21:44 PM
Creation date
4/11/2018 3:56:58 PM
Metadata
Fields
Template:
Address Document
Street Name
31ST DR
Street Number
3337
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Enemy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Unit F Townhome Polygon Northwest Company <br /> Eclipse Jamie Aubrey <br /> Everett,Wa (425)586-7700 <br /> Heating System Type: O Forced Air Furnace 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Instructions _. .. -::: ......_.._ . _. Design Temperature Difference(AT) 47 <br /> Everett 1C <br /> ST=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 1,381 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.5 11,739 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions 0.30 149 44.58 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions <br /> R-49 . 0.026 674 17.52 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> Instructions + <br /> L I No Vaulted Ceilings in this project I ` <br /> Above Grade Walls(see Figure 1) U-Factor Area UA <br /> Instructions <br /> 1R-21 662 37.07 <br /> Floors U-Factor Area UA <br /> Instructions ( - ---- --"- <br /> 1 112-30 ..........._ .........._� 0.029 564 16.36 <br /> Below Grade Walls_(see Figure 1) U-Factor Area UA <br /> Instructions <br /> rNo Below Grade Walls in this project. I --- --- <br /> Slab Below Grade(see Figure 1) F-Factor Length UA <br /> Instructions "----- -._...—.._.....--------------� l <br /> 'No Slab Below Grade in this project. V J --- <br /> Slab on Grade(see Figure 1) F-Factor Len.th UA <br /> Instructions .....::: ........... . ...___ ... <br /> 1. H-10 Perimeter w I 0.540 37 19.98 <br /> Location of Ducts <br /> Instructions _.... _..... Duct Leakage Coefficient <br /> Conditioned Space__ <br /> 1.00 <br /> Sum of UA 135.51 <br /> Envelope Heat Load 6,369 Btu/Hour <br /> Figure 1. Sum of UAX AT <br /> Air Leakage Heat Load 5,958 Btu/Hour <br /> VolumeX 0.6XST X.018 <br /> I Above Grade Building Design Heat Load 12,328 Btu/Hour <br /> a Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 12,328 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 17,259 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/01/13); 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.