My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3353 31ST DR 2018-04-12
>
Address Records
>
31ST DR
>
3353
>
3353 31ST DR 2018-04-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2018 12:02:21 PM
Creation date
4/12/2018 12:02:12 PM
Metadata
Fields
Template:
Address Document
Street Name
31ST DR
Street Number
3353
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size:Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Unit 6 Townhome Polygon=Northwest Company. 3. ;,_ .. <br /> Eclipse Jamie_Aubrey• . <br /> r <br /> Everett,Wa (425)586-7700' <br /> Heating System Type: O Forced Air Furnace Q Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Instructions _ Design Temperature Difference(OT) 47 <br /> Everett JC <br /> AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) ::;.1,960 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) __�xf,;, ,6i 16,660 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions 0.30 295 88.44 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions — '- — - <br /> R-,9 w li 0.026 872 22.66 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> Instructions r _ I <br /> 1 I No Vaulted Ceilings in this project +v I -- <br /> Above Grade Walls(see Figure 1) U-Factor Area UA <br /> Instructions <br /> -- <br /> R-2t . 0.056 1,883 105.45 <br /> Floors U-Factor Area UA <br /> Instructions0.029 570- 16.53 <br /> I <br /> I I R-30 --_H <br /> Below Grade Walls(see Figure 1) U-Factor Area UA <br /> Instructions I - - --- "--- <br /> L I No Below Grade Walls in this project. I J --- --- <br /> Slab Below Grade(see Figure 1) F-Factor Len th UA <br /> Instructions <br /> L I No Slab Below Grade in this project. J -- <br /> Slab on Grade(see Figure 1) F-Factor Len•th UA <br /> Instructions <br /> 1 I R-to Perimeter 0.540 88 47.52 <br /> Location of Ducts <br /> Instructions f _ Duct Leakage Coefficient <br /> I �Conditioned Space V <br /> ' — 1.00 <br /> Sum of UA 280.60 <br /> Envelope Heat Load 13,188 Btu/Hour <br /> Figure 1. Sum of UAXAT <br /> Air Leakage Heat Load 8,457 Btu/Hour <br /> �; \ VolumeX 0.6 X5TX.016 <br /> Above Grade . Building Design Heat Load 21,645 Btu/Hour <br /> ezr - , - - --. Air Leakage+Envelope Heat Loss <br /> °N `~ Building and Duct Heat Load 21,645 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 30,303 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (.1 <br /> -- (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.