Laserfiche WebLink
J <br /> � ' � � <br /> � Design Two Four/Two Six <br /> o � <br /> � � �� 42ND STREET SE � � 14835 161ST COURT SE <br /> '� RENTON, WA 98059-8819 <br /> � � STU� PIPES INTO ph. (425) 881-2426 � <br /> FOGTITE CONCRETE „�„ cll. (206) 335-7719 <br /> I J11 BOX W/ � � — � www.design2426.com <br /> IRRIGATION NOTES IRRIGATION SCHED _ <br /> � —" — � Wndscape Architedure•Irrigatlon Planning•Athletic Field Design•Construchon Management <br /> 1 . PROVIDE AND INSTALL ALL IRRIGATION IN CONFORMANCE WITH THE NONSKID LID M I I �_- = C Q � - � �� ; <br /> SYMB L MANUFACTURERf MODELf DESCRIPTION P I I � ; <br /> ' CITY OF EVERETT STANDARDS. IN THE EVENT OF CONFLICT APPROX. LOCATION � � � ,f�, � <br /> BETWEEN NOTES OR DETAILS AND THESE DOCUMENTS, THE o s o HUNTER RZWS-SLEEVE-36-CV 30 I OF EXISTING WATER � � I I <br /> STANDARDS SHALL TAKE PRECEDENCE. 36" LONG RZWS WITH FILTER FABRIC METER. SIZE � I �� � � <br /> SLEEVE, .25GPM OR .50GPM BUBBLER I UNKNOWN. USE 3/4 � � � �� � <br /> � <br /> 2. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES AND � IRRIGATION METER. �� APPROX. LOCATION OF : � � ��� <br /> APPROPRIATE SAFETY REGULATIONS. OPTIONS, CHECK VALVE, 1/2 S�WING I � I PROPOSED IRRIGATION � C O M M lJ N I T Y <br /> JOINT FOR CONNECTION TO 1/2 PIPE 'I I ' <br /> 2 CONTROLLER. COORDINATE � � � H E A L T H C E N T E R <br /> 3. DRAWING IS SCHEMATIC, ACTUAL LOCATIONS MAY VARY DUE TO � � � � � � EXI STI CATION W ARCHITECT � <br /> �" , , L0 � � -�'= N H MISH <br /> UTILITIES OR EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE 0 INSTALLATION. _ � ��� OF S O O <br /> YS MBOL MANUFACTURER f MODEL/DESCRIPTION � I � ' � � FOOTF PRIOR T � ., : . -��, a <br /> F O R L O C A T I N G U T I L I T I E S P R I O R T O B E G I N N I N G C O N S T R U C T I O N. / �I� . �_ " � �� � �-� ` C O U N T Y� <br /> � \ � i , , E X I S T. H T.. 3 9 8 .�- �. �, � <br /> 4. EXISTING STATIC P.S.I AT IRRIGATION METER IS 61 P.S.I � NETAFIM LVCZ 10075-�F E V�R E T T <br /> I I I I I �--- � :°' s-�..� i <br /> INFORMATION RECEIVED ON 07/13/17 PRIOR TO INSTALLATION OF 1 " VALVE, 3/4" FILTER AND A LOW FLOW � � � I I � I I I , _ � _ ' � � ( <br /> iRRIGA TI O N S Y S T E M, C O N T R A C T O R S H A L L F I E L D V E R I F Y E X I S T I N G P R E S S U R E R E G U L A T I N G V A L V E (0.2 5 - � � I I � � (Z O N E. E 1 M U 0) � .: - C E N T R A L <br /> P.S.I. NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES 4.4GPM). Q I I � � � � �~-� <br /> � I�I i �-=-- � � �Z�� <br /> BETWEEN THE DESIGN P.S.I. PRIOR TO PROCEEDING W/ WORK. � ( I I I I I `'"' ' � �, � ���� RUCKER AVENUE <br /> 5. SYSTEM DESIGNED TO 30 P.S.I. AT BUBBLER HEADS & 30 P.S.I. SYMBOL MANUFACTURERf MODELf DESCRIPTION W I \� I I I I � '-'-� '�' ``' ' EVERETT WA 98203 <br /> AT DRIPPERS. � � I I I � �° � � <br /> � HUNTER ICV-G-FS U � \ I I ���� ,:--� �,. <br /> 6. LOCATE UICK COUPLING VALVE & AUTOMATIC CONTROL VALVES 1 ", 1 -1 2", 2", AND 3" PLASTIC � �I I�I I I � � �;�� <br /> 4 , � � ( " ' ' � � � �� �° VLAD OUSTIMOVITCH <br /> AT POINT OF EASY ACCESS. OWNER S REPRESENTATIVE TO ELECTRIC REMOTE CONTROL VALVES, w � <br /> REVIEW & APPROVE FINAL LOCATION OF ALL QUICK COUPLERS & GLOBE CONFIGURATION, WITH NPT I � I I I I � <br /> AUTOMATIC CONTROL VALVES PRIOR TO INSTALLATION. THREADED INLET/OUTLET, FOR Z � � 4109 SW ORCHARD STREET <br /> W � � � � Eo <br /> COMMERCIAL/MUNICIPAL USE. WITH � � 9a� �� SEATTLE WA 98136 <br /> 7. HEAD LOCATION MUST BE ADJUSTED IN THE FIELD TO COMPLY FILTER SENTRY. I Q � <br /> W/ EXISTING SITE CONDITIONS AND PLANT MATERIALS. ADJUST � _ W BF ,� � � � � � - - - - <br /> SPRAY PATTERN FOR MAXIMUM COVERAGE AND MINIMUM HUNTER HQ 44LRC � _ _ _ _ }.� � Design Team <br /> O V E R S P R A Y. QUICK COUPLER VALVE, YELLOW RUBBER I � �.Mv �. ,;� _``== = W, - <br /> U � �:� � �� �. <br /> LOCKING COVER, RED BRASS AND I � — ' �� � �_____ � � �. � Design <br /> 8. CONTRACTOR SHALL COORDINATE IRRIGATION SLEEVING W/ PAVING STAINLESS STEEL, WITH 1 " NPT INLET, � ' ' � � V�N �� � ���, ��`�`�' ' a <br /> WORK AS REQUIRED. 2-PIECE BODY. I � � � � �� � �/�����'� I l; � JA <br /> . � I � l I I I Drawn <br /> � � ` � I 1 - ; � � I I �A <br /> 9. A L L I R R I G A T I O N S L E E V E S S H A L L B E T W I C E T H E D I A M E T E R O F T H E Z M A T C O-N O R C A 5 1 3 T ( I I I � � ��� �//a �y"' � I Checked <br /> INSERT PIPE S . SLEEVES SHALL NOT EXCEED 6" DIAMETER. 3/4"-2" BRONZE GAT E VAL V E, F U LL � � I I I 2 - 1 I � � � �1 �A <br /> C , PORT, HEAVY DUTY, NON-RISING STEM. I I I I i j j,,� I � ��� �'%' I I I °°te <br /> IPS WHEEL HANDLE. SAME SIZE AS � � I I I 3 I � � I-—, ' � 0�/�3/20�� <br /> 10. IRRIGATION CONTRACTOR TO PROVIDE AND INSTALL ALL REQUIRED , - <br /> I I ! �� � — — � 2426 Project No. <br /> PLUMBING SLEEVES WHERE NECESSARY. ALL IRRIGATION SLEEVING MAINLINE PIPE. i ��� ��/�/� � �" I �-= '- ;_ _ � � <br /> BE S AKED IN THE FIELD & LOCATED ON DIMENSIONED I ( 6� r � '_ - - �3� <br /> TO T �� I 1 � :,_ <br /> "AS-BUILT" DRAWING TO ALLOW FUTURE LOCATION & USE. `Mv HUNTER IB�!-FS 1 " I � , ,_ � � / Approved/Date <br /> 1 ", 1 _1/2", 2", AND 3" BRASS I � 1 -.�! I r��� ' �. � � <br /> 11 . AIR BLOW IRRIGATION SYSTEM THROUGH QUICK COUPLERS TO ELECTRIC MASTER VALVE, GLOBE I '''�� � I I <br /> WINTERIZE IRRIGATION SYSTEM. CONFIGURATION, WITH NPT THREADED / � � ' I I Revisions <br /> INLET/OUTLET, FOR / I � �% I I <br /> 12. PIPES TO SHARE TRENCHES WHERE POSSIBLE. SEPARATE COMMON No. Date Description <br /> �� COMMERCIAL/MUNICIPAL USE. WITH � � � � 4, � � C � � � � � � �, � � 1 7/13/17 Land Use Revision <br /> PIPING BY 6 MIN. FILTER SENTRY FACTORY INSTALLED � � � - `� I <br /> OPTION. I � I I I I � � �� - ', <br /> 13. WHERE PIPE SIZES ARE NOT SHOWN ON THE PLAN, PIPE SHALL , F;� � <br /> BE SIZED TO THE NEXT LARGEST PIPE SIZE SHOWN UPSTREAM eF FEBCO 850U 3 4" � I II I ( �'� � � � <br /> 0 N TH E P LAN. � � I �----.���..., � `-�-�,..;� I I �� � <br /> , DOUBLE CHECK BACKFLOW PREVENTION � I II I I �--��--� � � � � <br /> 14. GENERAL CONTRACTOR TO PROVIDE AND INSTALL ALL CONDUIT TO WITH UNION END BAL� VALVE, 1/2 TO I � I I I I � � � � � <br /> CONTROLLER LOCATIONS & POINTS OF CONNECTION. 2 ' � �� �y �//�j\ � �_ _ ��,� <br /> � ;��i� , � _ s <br /> 15. GENERAL CONTRACTOR TO PROVIDE POWER SOURCE FOR � WATER METER 3/4" I �� � <br /> CONTROLLERS. (VERIFY LOCATION W/ ARCHITECT PRIOR TO IRRIGATION LATERAL LINE: PVC SCHEDULE 40 � 30 � . <br /> BEGINNING WORK) � � � <br /> I � ���� Permit#: PW17Q6-012 <br /> I � Site Address: 4�0� RUCKER AVE <br /> IRRIGATION MAINLINE: PVC SCHEDULE 40 owner: COMMUNITY HEALTH CNTR OFSNOH CO <br /> Tenant: COMMUNIIY HEALTH CNTR OF SNOH CO <br /> - IRRIGATION MAINLINE: SCHEDULE 40 STD. STEEL PIPE App.Qate: 6/13/2d17 <br /> Proposed Use: <br /> ��.,�����,,,�, Description: IRRI�ATION PLANS(SEPARATE PLANS <br /> ��������° PIPE SLEEVE: PVC SCHEDULE 40 FROM CIVILS,SAME PERMIT#y <br /> va��e ca��o�t <br /> Valve Number Reviewed By: Qate: <br /> #�—Valve Flow QfFice Set �ala Site Set Fire/Planning Set <br /> #�� Valve Size <br /> Registration <br /> O� W A S,�/ <br /> P�5°���5 ti C� <br /> � ad b� o <br /> . � � . <br /> � <br /> `9����2�� <br /> CqpEpR��� <br /> Sheet Title <br /> � _=—_—� � <br /> �� <br /> � ! .� ..�.��� <br /> `� ��' <br /> ��� I � � I � � � I O � <br /> PLAN <br /> S e t No. <br /> 1 <br /> _ <br /> , ■ <br /> �Q 2009 DESIGN 2426 INC. <br />