My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
415 RIVERSIDE RD ZODIAC 2019-02-14
>
Address Records
>
RIVERSIDE RD
>
415
>
ZODIAC
>
415 RIVERSIDE RD ZODIAC 2019-02-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2019 11:35:53 AM
Creation date
4/13/2018 2:17:51 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERSIDE RD
Street Number
415
Tenant Name
ZODIAC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
213
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SERIES 632 <br /> Pass door leaf has perimeter trim to protect face finish and to provide The jamb is equipped with a mechanical rack and pinion gear drive <br /> visual identification as required by International Building Code. Pass mechanism and shall extend 4"-6"[100-152]by turning the <br /> door leaf incorporates a self-adjusting retractable bottom seal removable operating handle. <br /> providing sound control when door is closed. 2. Pivot Panel(Optional for heights to 12'3"137341 and a maximum of <br /> a.Automatic door closer 10 panels)`Pivot panel is attached to the wall and permits access <br /> b.Door lock between adjacent rooms. Pivot panel is of the same construction as <br /> c.Exit sign(consult your local code) basic panels but with continuous contact multi-ply vinyl top and <br /> d.Prepped for window bottom seals. The lead end of the panel has full height finger pull <br /> 2. Inset chalk/writing/projection surfaces and vertical seal of multi-ply vinyl <br /> 3. Inset tackboards E.Stack/Store Panels <br /> 4. Inset eraser pocket 1.Retract seals and move to storage area. Panels may be stored at <br /> 5. Segmented faces either or both ends of the track or in a pocket. <br /> 6. Finished end cover 2.04 ACOUSTICAL PERFORMANCE <br /> 7. Pocket doors A.Acoustical performance shall be tested at a laboratory accredited by the <br /> 8. Inset chair rail pan(for field installation of chair rail). U.S.Dept.of Commerce,National Institute of Standards and <br /> 9.Custom design options(consult your local Hufcor Distributor) Technology,under the National Voluntary Laboratory Accreditation <br /> 2.03 OPERATION Program(NVLAP)and in accordance with ASTM E90 Test Standards. <br /> A.Panels shall be manually moved from the storage area,positioned in Standard panel construction shall have obtained an STC rating of <br /> the opening,and seals set. (select as required): 41,43,47,49,51 <br /> B.Retractable Horizontal Seals (Not all substrates are available in all STC ratings) <br /> 1. Retractable horizontal seals shall be activated by a removable quick- 1. Complete,unaltered written test report is to be made available upon <br /> set operating handle located approximately 42"[1067]from the floor request. <br /> in the panel edge. <br /> 2.All retractable seals in each hinged pair shall be operated PART 3-EXECUTION <br /> simultaneously. A.Installation. The complete installation of the operable wall system shall <br /> 3. Seal activation requires approximately 15 lbs.[6.8 kg]of force per be by an authorized factory-trained installer and be in strict accordance <br /> panel and approximately a 190 degree turn of the removable handle. with the approved shop drawings and manufacturer's standard printed <br /> C.Automatic Floor Seals specifications,instructions,and recommendations. <br /> 1. Horizontal seals shall be activated by pressing the edge of the panel B.Cleaning <br /> into the edge of the adjacent panel or wall. 1.All track and panel surfaces shall be wiped clean and free of <br /> 2.Seal activation requires approximately 15 lbs.[6.8 kg]of force per handprints,grease,and soil. <br /> panel. 2. Cartoning and other installation debris shall be removed to onsite <br /> D.Final partition closure to be by(select one): waste collection area,provided by others. <br /> 1. Lever closure panel with expanding jamb which compensates for C.Training <br /> minor wall irregularities and provides a minimum of 250 lbs.[113.4kg] 1. Installer shall demonstrate proper operation and maintenance <br /> seal force against the adjacent wall for optimum sound control. The procedures to owner's representative. <br /> jamb activator shall be located approximately 45"[1143]from the 2.Operating handle and owners manuals shall be provided to owner's <br /> floor in the panel face and be accessed from either side of the panel. representative. <br /> Header shown for `1 2 1/4"'' <br /> plenum sound I..------.-1 . SOUND ATTENUATION BY OTHERS <br /> enclosure is one of (57] .. 1/2"[13)(MIN.)GYPSUM BOARD ON <br /> several that may be z ..—CONTINUOUS METAL STUDS BY OTHERS <br /> used.See ASTM m <br /> E557 Standard N . die <br /> 3/8"[10)0 HANGER RODS <br /> Practice for Archl zo <br /> Application& " <br /> Installation of 4116, <br /> n ._ �. A CEILING BY OTHERS <br /> t.�Gltil. fr.4 l <br /> Operable Partitions z 1/2"[sa) OMB 1 J 1 <br /> for other ilhb ' , ,I 1 11 ) <br /> I�I I ill . I <br /> recommendations. L 43/4 (121)" ni <br /> _...1 1-(25j if 1"[25) <br /> Type 38 Aluminum <br /> track. Standard for <br /> weights to 400 lbs. <br /> [182 kg]. Alternate <br /> track system to be l <br /> used for weights • i LJ <br /> exceeding 400 lbs. _ _.%._____N___ <br /> I <br /> z <br /> 33"1761 <br /> I 1 31/2"[891 <br /> ] <br /> 2"[51]MAX <br /> }� — TOP OF FIN.FLOOR A. <br /> L FLOOR \ TOP OF SLAB <br /> HIHUFCOR COVERING No Scale <br /> THICKNESS Vertical Section <br /> FigillOin brackets[ [are in millimeters unless otherwise lip. 4w yam__ <br />
The URL can be used to link to this page
Your browser does not support the video tag.