Laserfiche WebLink
a <br /> Technical Data Applicable Standards For best painting results, all surfaces, <br /> Surface Burning Characteristics and References including joint compound,should be <br /> • ASTM 01396 clean, dust-free and not glossy. If glossy <br /> CertainTeed Type C Gypsum Board paints are used, a thin skim coat of <br /> has a Flame Spread rating of 15 and • ASTM C840 compound over the entire surface, Level <br /> Smoke Developed rating of 0, in 5 finish, is recommended to reduce <br /> (UL 723, <br /> accordance with ASTM E84, ' CAN/CSA A82.31 <br /> highlighting or joint photographing.This <br /> NFPA 255,CAN/ULC-S102). • Gypsum Association GA-216 method is also recommended for areas <br /> Fire Resistance • Gypsum Association GA-214 of critical sidelighting of natural or <br /> artificial light sources. <br /> Fire resistance tests are conducted in • ICC International Building Code(IBC) <br /> accordance with ASTM El 19, A sealer application under wallpaper or <br /> (ANSI/UL 263,NFPA 251,CAN/ULC-5101) • National Building Code of Canada other wall covering is also recommended <br /> and no warranty is made other than (NBCC) so the board surface will not be <br /> conformance to the standard under which • Meets and exceeds Type X requirements damaged if the covering is subsequently <br /> the assembly was tested.Minor removed during redecorating.Joint <br /> discrepancies may exist in the values of treatment must be thoroughly dry before <br /> ratings,attributable to changes in Installation proceeding with primer-sealer application <br /> materials and standards,as well as Recommendations and final decoration. <br /> differences between testing facilities. Installation of CertainTeed Type C Gypsum <br /> Assemblies are listed as"combustible" Boards should be consistent with methods Notice <br /> (wood framing)and"noncombustible" described in the standards and references The information in this document is <br /> (concrete and/or steel construction). noted.Cutting should be from the face subject to change without notice. <br /> For fire resistance rating,refer to the side of the boards for best results. CertainTeed assumes no responsibility for <br /> Gypsum Association Fire Resistance Decoration any errors that may inadvertently appear <br /> Design Manual and UL Fire Resistance CertainTeed Type C Gypsum Board in this document. <br /> Directory—Vol.1 or ULC Fire Resistance accepts most types of paints,texture and <br /> List of Equipment and Materials. wall covering materials.The surface shall <br /> UL/cUL/ULC Type Designation listed in be primed and sealed with a full-bodied <br /> Fire Resistance Directories-Type C. latex primer before applying a final <br /> CertainTeed Type C meets and exceeds decorative material.This will equalize the <br /> the Type X requirements of ASTM C1396 suction between the joint compounds and <br /> and CAN/CSA-A82.27. the paper surface. <br /> O <br /> •STM <br /> GREENGUARD <br /> ---", Health Product PRODUCT CERTIFIED FOR <br /> ��� DECLARATION OWCHE 71CALEMISSIONS <br /> o© UL.2COM/GG <br /> 8W <br /> The Health Product Declaration"and UL DU <br /> l550 is owned by the Health Product <br /> ',yeMe�p yJ MEMBER Declaration Collaborative'"and is GOLD <br /> ^,r K. used with permission. <br /> .---- 7-"Th <br /> _n11flJ U ll _ CertainTeed Corporation F <br /> x ROOFING • SIDING • TRIM • DECKING • RAILING • FENCE • GYPSUM • CEILINGS • INSULATION <br /> SAI NT-GOBAI N 20 Moores Road Malvern,Pa 19355 Professional;800-233-8990 Consumer:800-782-8777 certainteed.com <br /> Ca 12/16 CertainTeed Corporation,Printed in the USA Code No.CTG-2319 <br />