My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11225 19TH AVE SE ARTESIA APARTMENTS 2023-07-03
>
Address Records
>
19TH AVE SE
>
11225
>
ARTESIA APARTMENTS
>
11225 19TH AVE SE ARTESIA APARTMENTS 2023-07-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2023 11:05:28 AM
Creation date
4/16/2018 9:07:42 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
11225
Tenant Name
ARTESIA APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
316
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Operation 2) Total current for nonresettable power, resettable power and <br /> Activation of a compatible smoke detector or any normally-open two NACs must not exceed 6.0 A for the MS-4(required optional <br /> fire alarm initiating device activates audible and visual signaling second transformer). <br /> devices, illuminates an indicating LED, sounds the piezo CABINET DIMENSIONS <br /> sounder at the FACP, activates the FACP alarm relay and oper- Door: 15.342" (38.97 cm) high x 14.667' (37.28 cm) wide x <br /> ates an optional module used to notify a remote station or initi- 0.375"(0.95 cm)deep. <br /> ate an auxiliary control function. Backbox: 15.0" (38.10 cm) high x 14.5' (36.83 cm)wide x 3.0" <br /> (7.62 cm)deep. <br /> Specifications BACKBOX MOUNTING <br /> AC POWER-TB3 The cabinet can be surface mounted. The door is removable <br /> • MS-4: 120 VAC,50/60 Hz,2.3 A. during installation by opening and lifting it off the hinges. The <br /> • MS-4E:240 VAC,50 Hz, 1.15 A. cabinet mounts using two key slots at the top of the backbox and <br /> • Wire Size: Minimum 14 AWG(2.0 mm2)with 600 V insulation. two additional 0.25'diameter holes at the bottom. <br /> BATTERY(SEALED LEAD-ACID ONLY)-J8 <br /> • Maximum charging circuit: normal flat charge 27.6 VCD @ Listings and Approvals <br /> 0.8 A. • UL Listed: S624 <br /> • Maximum battery charger capacity: 18.0 AH battery (two • MEA: 297-01-E <br /> 7.0 AH batteries can be housed in the FACP cabinet. Larger • CSFM:7165-0075:200 <br /> batteries require a separate battery box such as the Fire-Lite <br /> BB-17F). Ordering Information <br /> INITIATING DEVICE CIRCUITS-TB3 MS-4: Four-zone conventional FACP; 120 VAC,50/60 Hz,2.3 A. <br /> • Alarm zones 1 -4. MS-4E: Same as above, but 240 VAC, 50 Hz, 1.15 A operation. <br /> • Power-limited circuitry. CAC-4: Class A converter module. Used to convert Style B <br /> • Operation:all zones Style B(Class B). (Class B) IDC to Style D(Class A)and Style Y(Class B)NAC to <br /> • Normal operating voltage: nominal 20 VDC. Style Z (Class A). The module connects to J1 on the MS-4 cir- <br /> • Alarm current: 15 mA minimum. cuit board. <br /> • Short-circuit current:40 mA maximum. 4XTMF:Transmitter module. <br /> • Maximum loop resistance: 100 ohms. 4XLMF: LED interface module. <br /> • End-of-line resistor:4.7K ohm, 112 watt(P/N 71252). 4XZMF:Zone relay module,4 form C relay. <br /> • Standby current:4 mA. RZA:-4XF: Remote Annunciator. <br /> • Compatible devices: refer to the Fire-Lite Device Compatibil- BB-17F: Battery box, required to house two batteries greater <br /> ity Document PN 15384 for a complete list of compatible than 7 AH to a maximum of 18 AH. <br /> devices. 411/411UD: Three-input (channels) model 411, and four-input <br /> model 411 UD, dual-line Digital Alarm Communicator/Transmit- <br /> NOTIFICATION APPLIANCE CIRCUITS-T62 ters (DACTs). Can be used as slave communicators with the <br /> • Two NACs. FACP. <br /> • Power-limited circuitry. DP-MS2/4: Optional dress panel. <br /> • Normal operating voltage:nominal 24 VDC. MS-4RB: Replacement board. <br /> • Maximum signalling current: 2.5 A total with standard trans- TR-1-R: Optional trim ring for semi-flush mounting. <br /> former 5.0 A total (2.5 A maximum per NAC) with optional A 2-zone version of this panel is also available. See DF-52211. <br /> transformer. <br /> • End-of-line resistor:4.7K ohm,1/2 watt(P/N 71252). <br /> • Compatible devices: refer to the Fire-Lite Device Compatibil- <br /> ity Document PN 15384 for a complete list of compatible <br /> devices. <br /> FORM-C RELAYS <br /> • Trouble Relay TB5(fail-safe). <br /> • Alarm Relay TB6. <br /> • Supervisory relay TB7. <br /> • Relay contact ratings:2.0 A @ 30 VDC(resistive). <br /> AUXILIARY OUTPUT:RESETTABLE POWER-TB1 <br /> • Operating voltage: nominal 24 VDC. <br /> • Maximum available current: 500 mA-appropriate for pow- <br /> ering four-wire smoke detectors (see notes). <br /> • Power-limited circuitry. Fire-Lite®Alarms is a registered trademark of Honeywell International Inc. <br /> y. ©2011 by Honeywell International Inc.All rights reserved.Unauthorized use <br /> Notes: 1) Refer to the Fire-Lite Device Compatibility Document of this document is strictly prohibited. <br /> for a complete list of compatible devices. <br /> I�O �oo� This document is not intended to be used for installation purposes. <br /> We try to keep our product information up-to-date and accurate. <br /> We cannot cover all specific applications or anticipate all requirements. <br /> ENGINEERING 8 MANUFACTURING All specifications are subject to change without notice. <br /> QUALITY SYSTEMS Made in the U.S.A. <br /> For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. <br /> www.firelite.com <br /> Page -DF-52266:132.12/21/2012 <br /> 3� <br />
The URL can be used to link to this page
Your browser does not support the video tag.