6. Please indicate exit signage and emergency illumination on the reflected ceiling plans, <br /> per IBC sections 1006.3 and 1011.1. See G.1.2.0 <br /> Please see exits signs at sheet G1.2.C,please see revised sheet A3.11A.C, RCP with <br /> exit signs and emergency illuminate (clouded area) <br /> 7. Braille exit signage should be indicated on the plans per IBC section 1011.4. <br /> Please see revised sheet A3.11A.C, RCP with Braille signs (clouded area) and also <br /> the detail on A9.1.0 <br /> 8. Pull side dimension of new door(112) should be shown on the drawings as 18 inches, <br /> per ICC/ANSI A117.1-2009 figure 402.3.2 (a). <br /> Please see floor plan A2.11.0 (clouded area) on door 112. <br /> 9. Hardware should be shown on the door schedule to operate without tight twisting or <br /> grasping requiring use of the wrist,per IBC section 1008.1.9.1. <br /> Please see photo of door level on sheet A2.32.0 (clouded area) <br /> 10. Door lites should be shown on the drawings to comply with the heights listed in <br /> ICC/ANSI A117.1-2009 section 404.2.10. <br /> Door with vision panel (door lite) is not used;please see revised door elevation <br /> (crossed out and clouded) on sheet A2.32.C. <br /> Accessibility <br /> 1. IBC sections 1106.1 and 1106.5 require a van accessible parking space where 1 to 25 <br /> parking spaces are provided. <br /> a. A facility that is altered should comply with applicable sections of requirements <br /> for new construction, unless technically infeasible,per IBC section 3411.7. <br /> b.Where an alteration affects the accessibility to a primary function,the route to the <br /> primary function area should be accessible,per IBC section 3411.7. <br /> i. The cost of providing the accessible route is not required to exceed 20 <br /> percent of the costs of the alterations affecting the area of primary <br /> function. <br /> c. The van accessible space is required to be a total of sixteen feet, with an access <br /> aisle of either 5 or 8 feet,per ICC/A117.1-2003 section 502.2. <br /> d.Please note the words ADA on the parking spaces reference a law, but not a <br /> requirement of the building code. <br /> See General item#4 response <br /> 2. Parking signage should be shown on the drawings to comply with IBC section 1110.1 <br /> and ICC A117.1-2003 section 502.7. The minimum height to the underside of the sign is <br /> 5'-0" above adjacent grade <br /> See General item#4 response <br /> Eil/ <br />