GENERAL NOTES: (R311.7.8) HANDRAILS. 2015 WASHINGTON STA E ENERGY CO REVISIONS: <br /> HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR MORE ResponsetoCltyofEverettLetter10,10.16 <br /> THESE DOCUMENTS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT. REPRODUCTION OR USE OF THESE RISERS. �•Drawings Revlsed 10.20,16 <br /> DOCUMENTS BEYOND THE SCOPE OF THIS PROJECT IS PROHIBITED WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT. (R302.1) DESIGN CONDITIONS <br /> (R311.7.8,1)HANDRAIL HEIGHT MEASURED VERTICALLY SHALL NOT BE LESS THAN 34"AND NOT MORE THAN 38". 2, <br /> (R311.7.8.2)CONTINUITY. HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULI. LENGTH OF THE FLIGHT. HANDRAILS ENDS (R302.1) INTERIOR DESIGN CONDITIONS. INTERIOR TEMPERATURES USED FOR HEATING AND COLLOING LOAD CALCULATIONS SHALL BE <br /> A MAX. OF 72° FOR HEATING AND 75° FOR COOLING. 3 <br /> 1. CONFORM TO ALL APPLICABLE CODES &REGULATIONS. SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS . HANDRAI�S ADJACENT TO WALL SHALL HAVE A SPACE OF NOT LESS (R302.2) EXTERIOR DESIGN CONDITIONS PER TABLE (R301.1)4C SNOHOMISH COUNTY. C=MARINE. <br /> 2015 International Residential Code(2015 IRC) THAN 1 1/2" BETWEEN THE WALL AND HANDRAIL. 4 <br /> 2015 WA State Energy Code(WSEC) (R311.7.8.3)GRIP SIZE. (R303) MATERIALS, SYSTEMS AND EQUIPMENT <br /> 2015 International Mechanical Code TYPE I MIN. 1 1/4", MAX.2° CIRCULAR CROSS SECTION. (R303.1.1.1) BLOWN OR SPRAYED ROOF/CEILING INSULATION. THE THICKNESS SHALL BE WRITTEN IN INCHES ON MARKERS THAT ARE 5' <br /> 2. VERIFY ALL CONDITIONS & DIMENSIONS IN FIELD BEFORE STARTING WORK, &REPORT ANY DISCREPANCIES TO THE TYPE II REQUIRED GRASPABLE FINGER RECESS BOTH SIDES INSTALLED AT LEAST ONE FOR EVERY 300 S.F.THROUGHOUT THE ATTIC. R-VALUE SHALL BE LISTED ON CERTIFICATE <br /> ARCHITECT. PROVIDED BY THE INSULATION INSTALLER. <br /> 3. TAKE EVERY PRECAUTION TO SAFEGUARD PERSONS& PROPERTY. R303.7 INTERIOR STAIRWAY ILLUMINATION (R303.2.1) PROTECTION OF EXPOSED FOUNDATION INSULATION. INSULATION APPLIED TO THE EXTERIOR OF BASEMENT, CRAWLSPACE pq <br /> 4. STORE MATERIALS IN AREA APPROVED BY OWNER. PROTECT ALL BUILDING MATERIALS FROM WEATHER DURING A�L INTERIOR AND EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH A MEANS TO ILLUMINATE THE STAIRS, INCLUDWG THE LANDINGS WALLS AND THE PERIMETER OF SLAB-ON-GRADE SHALL HAVE RIGID, OPAQUE AND WEATHER-RESISTANT PROTECTIVE � � <br /> CONSTRUCTI(3N. PROTECT CONSTRUCTION FROM WEATHER AS WORK PROCEEDS. AND TREADS. INTERIOR STAIRS SHALL BE CAPABLE OF ILLUMINATfNG TREADS AND LANDING TO LEVELS NOT LESS THAN 1 w � � '� <br /> COVERING AND SHALL COVER THE EXPOSED EXTERIOR INSULATION AND EXTEND A MIN. OF 6"BELOW GRADE. H � �'' � o 0 <br /> 5. REPAIR ALL DAMAGES CAUSED BY CONSTRUCTION IN THIS CONTRACT. FOOT-CANDLE. � � � � � � � <br /> 6. REMOVE DEBRIS FROM THE BUfLDING SITE AS IT ACCUMULATES TO PREVENT UNSAFE CONDITIONS. (R303.7.1} LIGHT ACTIVATION. SWITCH REQUIRED TOP AND BOTTOM OF INTERIOR STAIRS GREATER AND OR EQUAL TO 6 RISERS. (R402)BUILDING THERMAL ENVELOPE � � � � � o <br /> � rn � �1 q <br /> 7. ELECTRICAL& MECHANICAL WORK UNDER SEPARATE PERMIT. SWITCH FOR EXTERIOR LIGHT INSIDE DWELLING OR AUTOMATICALLY CONTROLLED. (R402.2.1)CEILINGS WITH ATTIC SPACES WOULD REQUIRE R-49 IN THE CEILING, INSTALLING R-38 OVER 100 PERCENT OF THE CEILING c�z � � � �' �' -" <br /> 8. INSTALL AND APPLY MATERIALS PER MANUFACTURER'S INSTRUCTIONS &RECOMMENDATIONS. c� � cfl � p � <br /> AREA SHALL BE DEEMED TO SATISFY THE REQUIREMENT OF R-49 WHEREVER THE FULL HEIGHT OF UNCOMPRESSED R-38 ,� o a •� � <br /> 9. DIMENSIONS GIVEN ARE TO FACE OF STUD FRAMING, FACE OF CONCRETE OR MASONRY, &TO CENTER OF OPENING SECTION R312 GUARDS AND WINDOW FALL PROTECTION A v� 'r� � <br /> INSULATION EXTENQS OVER THE WALL TOP PLATE AT THE EAVES. O � � � <br /> UNLESS OTHERWISE NOTED. (R312.1.1)REQUIRED FOR OPEN-SIDED WALKING SURFACE GREATER THAN 30"ABOVE FLOOR OR GRADE WITHIN 36"HORIZONTALLY OF py O � �''� •d .d � <br /> 10. PERMIT NO SMOKING IN BUILDING. OPEN SIDE (R4 02.2.1.1) L O O S E I N S U L A T I O N I N A T T I C S P A C E S M A Y B E U S E D I N A T T I C S P A C E S W H E R E T H E S L O P E O F T H E C E I L I I N G IS N O T M O R E � � . � <br /> (R312.1.2) HEIGHT. REQUIRED GUARDS SHALL BE NOT LESS THAN 36 (34 IF GUARD IS STAIR HANDRAIL) THAN 3 FEET IN 12 AND THERE IS AT LEAST 30" OF CLEAR DISTANCE FROM THE TOP OF THE BOTTOM CHORD OF THE TRUSS .-� � x � o <br /> 11. VERIFY FIGURES SHOWN ON THE DRAWINGS BEFORE LAYING OUT THE WORK. REPORT ERRORS&/OR " " c+� c�. <br /> OR CEILING JOIST TO THE UNDERSIDE OF THE SHEATHfNG AT THE ROOF RIDGE o h � � <br /> INACCURACIES IN WRITING TO THE ARCHITECT BEFORE COMMENCWG WORK. MEASURE HEIGHT VERTICALLY FROM FIXED SEATING. (R402.2.3)EAVE BAFFLE IN VENTED ATTICS SHALL MAWTAIN AN OPENING EQUAL OR GREATER THAN THE SIZE OF THE VENT. THE � � .� <br /> 12. WRITTEN DIMENSIONS SUPERSEDE SCALED DRAWINGS. (R312.1.3)OPENING LIMITATIONS. GUARDS SHALL NOT HAVING OPENINGS THAT ALLOW PASSAGE OF A SPHERE 4" IN DIAMETER. BAFFLE SHALL EXTEND OVER THE TOP OF THE ATTIC INSULATION. �3 <br /> 13. WRITTEN NOTES SUPERSEDE GRAPHIC DEPICTIONS. EXCEPTION:6"SPHERE AT SPACE BETWEEN RISER, TREAD&RAIL.4 3/8"SPHERE AT OPEN SIDE OF STAIRS. ` � <br /> (R402.2.4)ACCESS HATCHES AND DOORS FROM CONDITIONED SPACES TO UNCONDITIONED SPACES SHALL BE iNEATHERSTRIPPED AND � <br /> 14. ENGINEERING SPECIFICATIONS SUPERSEDE DRAWINGS. -f--� <br /> INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. � E°"� <br /> 15. ALIGN WINDOW& DOOR HEADS UNO. SECTION R807 ATTIC ACCESS EXCEPTIONS:VERTICAL DOORS THAT PROVIDE ACCESS SHALL BE PERMITTED TO MEET THE FENESTRATION REQUIREMENTS OF � � � � <br /> 16. ALL HAZARDOUS MATERIALS SHALL BE REMOVED BY A LICENSED ABATEMENT CONTRACTOR, PRIOR TO ANY DEMOLITION OR ACCESS REQUIRED IF GREATER OR EQUAL THAN 30" NET HEIGHT BETWEEN FRAMWG&GREATER THAN 30 SQ. FT. TABLE (R402.1.1) � � <br /> ACTIVITY WHICH WOULD DISTURB THE MATERIAL. ROUGH OPENING MIN.22"X 30" A <br /> MIN. 30" HEADROOM AT LEAST ONE POINT ABOVE HATCH (R402.2J} FLOORS. CAVITY INSULATION SHALL BE INSTALLED TO MAINTAIN PERMANENT CONTACT WITH THE UNDERSIDE OF THE � � .,... <br /> SUBFLOOR DECKING. I--� � H � <br /> ARCHITECTURAL&LIFE SAFETY(2015 IRC) OPENING MUST ALLOW REMOVAL OF ATTIC MECHANICAL EQUIPMENT. (SEE SECTION M1305.1.3) EXCEPTIONS: 2. WHEN FOUNDATION VENTS ARE NOT PLACEQ SO THAT THE TOP IS BELOW THE LOWER SURFACE OF THE FLOOR U� -�-� � � <br /> (SECTION R317) PROTECTION OF WOOD AND WOOD BASED PRODUCTS AGAINST DECAY SECTION R8Q6 ROOF VENTILATION INSU�ATION,A PERMANENTLY ATTACHED BAFFLE SHALI BE INSTALLED AT AN ANGLE OF 30° FR4M HORIZONTAL,TO w � � o <br /> (R317.1) LOCATION REQUIRED. PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE PROVIDED IN THE (R806.1)VENTILATION REQUIRED.VENT EACH ENCLOSED ATTIC&ENCLOSED RAFTER BAY DIVERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION. Q � Q, <br /> FOLLOWIING LOCATIONS. OPENINGS LEAST DIMENSION MIN. 1/16" MAX. 1J4" (R402.2.8) BELOW-GRADE WA�L INSULATION USED ON THE EXTERIOR(COLD)SIDE OF THE WALL SHALL EXTEND FROM THE TOP OF �j � <br /> BELOW-GRADE WALL TO THE TOP OF FOOTING AND SHALL BE APPROVED FORBELOW-GRADE USE.ABOVE GRADE � e� v <br /> 1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18"OR WOOD GIRDERS WHEN CLOSER OPENINGS GREATER THAN 1/4" REQUIRED 1/16"TO 1/4" MESH SCREENING INSULATION SHALL BE PROTECTED. INSULATIC)N USED ON THE INTERIOR(WARM)SIDE OF THE WALL SHALL EXTEND FROM � <br /> THAN 12"TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED WITHIN THE PERIPHERY OF THE (R806.2)MIN. NET OPENING AREA 1/150 TH OF VENTED AREA OR 1/300TH IF 40%-50% MIN. 3'ABOVE EAVE OR CORNICE VENTS <br /> TOP OF THE BELOW GRADE WALL TO THE BELOW GRADE FLOOR LEVEL AND SHALL INCLUDE R-5 RIGID BOARD PROVIDING A �c' <br /> BUILDING FOUNDATIOIN. (R806.3)VENT AND INSULATION CLEARANCE. NOT LESS THAN 1"CLEARANCE TO SHEATHING NEAR VENTS THERMA� BREAK BE7WEEN THE CONCRETE WALL AND THE SLAB. � <br /> 2. AL�WOOD FRAMING MEMBER THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8" (R806.5)UNVENTED ATTIC AND UNVENTED ENCLOSED RAFTER ASSEMBLIES OK WITHIN BUILDING THERMAL ENVELOPE (R402.2.9)SLAB-ON-GRADE FLOOR MIN. THERMAL RESISTANCE (R-VALUE)OF INSULATION AROUND THE PERIMETER OF UNHEATED OR A <br /> FROM THE EXPOSED GROUND. HEATED SHALL BE AS SPECIFIED lN TABLE R401.1.1.THE INSULATION SHALL BE PLACE ON THE OUTSIDE OF THE FOUNDATION � o <br /> 3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS SEPARATED SECTION R309 GARAGES AND CARPORTS OR ON THE INSIDE OF THE FOUNDATION WALL. THE INSULATION SHALL EXTEND DOWNWARD FROM THE TOP OF THE SLAB `� <br /> FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER. GENERAL FOR A MIN. DISTANCE AS SHOWN IN THE TABLE OR TO THE TOP OF THE FOOTWG,WHICHEVER IS LESS, OR DOWNWARD TO � <br /> 4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2"ON (R309.1&2) FLOOR SURFACE. GARAGE AND CARPORT FLOORS SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL. AT LEAST TNE BOTTOM OF THE SLAB AND THEN HORIZONTALLY TO THE INTERIOR OR EXTERIOR FOR THE TOTAL DISTANCE �r'°"" '� <br /> TOPS, SIDES AND ENDS. (R309.2}CARPORTS SHALL BE OPEN ON NOT LESS MORE 2 SIDES. NOT OPEN ON 2 OR MORE SIDES SHALL BE CONSIDERED A GARAGE SHOWN IN THE TABLE. A 2 X2 MAX. P.T. NAILER MAY BE PLACED AT THE FINISHED FLOOR ELEVATION FOR ATTACHMENT OF a <br /> 5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6" FROM COMMON WALLS, CEILINGS&PENETRATIONS INTERIOR FINISH MATERIALS. INSULATION EXTENDING AWAY FROM THE BUILDING SHALL BE PROTECTED BY PAVEMENT OR " <br /> THE GROUND OR LESS THAN 2" MEASURED VERTICALLY FROM CONCRETE STEPS, PORCH SLABS, PATIO SLABS,AND SIMILAR (TABLE R302.6) MIN. 1/2"GYPBOARD ON GARAGE SIDE BY A MIN. OF 10" OF SOIL. � <br /> HORIZONTAL SURFACES EXPOSED TO THE WEATHER. 5/8"TYPE X GYPBOARD ON GARAGE CEILING UNDER HABITABLE ROOMS <br /> 6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE WEATHER, MIN. 1/2" GYPBOARD ON WALLS SUPPORTING SUCH CEILING (R402.2.9.1) HEATED SLAB-ON-GRADE FLOORS SHALL BE THERMALLY ISOLATED FROM THE SOIL WITH A MIN. OF R-10 INSULATION. <br /> SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS MOISTURE (R302.5.1) NO OPENINGS BETWEEN GARAGE&SLEEPING ROOMS (R402.4,1.2)TEST AND VERIFY AS HAVING AN AIR LEAKAGE RATE OF NOT EXCEEDING 5 AIR CHANGES PER HOUR. <br /> BARRIER. DOORS BETWEEN HOUSE&GARAGE 20-MINUTE FIRE-RATED OR 1 3/8"THICKNESS, SOLID OR HONEYCOMB CORE STEEL, (EXCEPTIONS) 1.ADDITI(3NS LESS THAN 500 S,F. OF CONDITIONED FLOOR AREA. <br /> 7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY EQUIPPED WfTH A SELF-CLOSING DEVICE. 2.ADDITIONS TESTED WITH THE EXISTING HOME HAVING ACOMBINED MAX.AIR LEAKAGE RATE OF 7 AIR CHANGES � <br /> WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL (R302.5.2)DUCTS FROM HOUSE TO GARAGE MIN. NO.26 GAGE SHEET OR APPROVED MATERIAL AND SHALL NOT HAVE OPENINGS INTO PER HOUR. <br /> AND THE FURRING STRIPS OR FRAMING MEMBERS, THE GARAGE. (R402.4.2)NEW WOOD-BURNING FIREPLACES SHALL HAVE TIGHT-FITTING FLUE DAMPERS OR DOORS AND OUTDOOR COMBUSTION � <br /> (R302.5.3)APPROVED SEALANT MATERIAL AT PENETRATIONS TO HOUSE AIR. � <br /> (R317.1.1} FIE(,D TREATMENT. FIELD-CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE-TREATED WOOD SHALL BE TREATED (R402.4.3)AIR LEAKAGE OF FENESTRATION (WINDOWS, SKYLIGHTS AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION � <br /> IN THE FIELD IN ACCORDANCE WITH AWPA M4. SECTION R905 REQUIREMENTS FOR ROOF COVERINGS RATE OF NO MORE THAN 0.3 CFM PER S.F.AND SWINGING DOORS NO MORE THAN 0.5 CFM PER S.F. � <br /> (R905.2.1)ASPHALT SHINGLES SHALL BE FASTENED TO SOLIDLY SHEATHED DECKS. (EXCEPTIONS) 1. FIELD-FABRICATED FENESTRATION PRODUCTS(WINDOWS, SKYLIGHTS AND DOORS). �� <br /> 2. CUSTOM EXTERIOR FENESTRATION PRODUCTS MANUFACTURER BY A SMALL BUSINESS PROVIDED THEY MEET THE <br /> �SECTION R308}GLAZING (R803.2.1&2)WOOD STRUCTURAL PANELS REQUIRED GRADE STAMP&SPAN RATING V� <br /> (R308.4.1 through R308.4.7} HAZARDOUS LOCATIONS REQUIRING SAFETY GLASS (T602.3(1)) NAIL TO SCHEDULE (6" EDGE- 12" FIELD MIN.) APPLICABLE PROVISION5 OF CHAPTER 24 OF IBC. <br /> GLASS W SWINGING, BIFOLD, OR SLIDING DOORS(EXCEPTION#1) (R402.4.5) RECESSED LIGHTING INSTALLED IN THE SUILDING THERMAL ENVELOPE SHALL BE TYPE lC-RATED AND CERTIFIEQ UNDER � r <br /> -DECORATIVE GLAZING OR OPENINGS W/LESS THAN 3°I.EAST DIMENSION RUOF COVERINGS: GENERAL ASTM E283 AS HAVING AN AIR LEAKAGE RATE NOT MORE THAN 2.0 CFM. ALL RECESSED LUMINAIRES SHALL BE SEALED � � Q <br /> SIDELITES WHERE GLASS IS WITHIN LESS THAN OR EQUAL TO 24"ARC OF DOOR FRAME&ANY PART OF GLASS LESS THAN 60"ABOVE (R902.1)CLASS A, B, OR C FIRE RATING REQUIRED IF E�GE LESS THAN 3' FROM PROPERTY LINE OR PER LOCAL LAW WITH A GASKET OR GAULK BETWEEN 7HE HOUSING AND THE INTERIOR WALL OR CEILING COVERING. � � <br /> FLOOR OR WALKING SURFACE (R904.4)MATERIALS REQUIRE MANUFACTURER IDENTIFICATION &AGENCY APPROVALS ; = Q � <br /> -DECORATIVE GLAZING OR WHERE SEPARATED BY WALL OR INTERVENING BARRIER (R903.1)ROOF DECKS SHALL BE COVERED WITH APPROVED ROOF COVERINGS PER MANUFACTURER'S INSTRUCTIONS. 0 <br /> -WHERE DOOR ONLY ACCESSES CLOSET LESS THAN 3 FT. DEEP (R903.2) FLASHING REQUIRED AT ROOF/WALL INTERSECTIONS, PENETRATIONS, CHIMNEYS, ETC. <br /> t� '�' Q <br /> -GLASS PERPENDICULAR TO DOOR&ON LATCH SIDE WHEN CLOSED � � <br /> -GLASS ADJACENT TO FIXED PANEL OF PATIO DOORS SLOPED ROOFING � �j <br /> WINDOWS W/WALK-THROUGH HAZARD, INCLUDING ALL OF: (1)EXPOSED AREA OF GLAZING LESS THAN 9 SQ. FT. (2) BOTTOM EDGE LESS (R905.2-8) MINIMUM 24" ICE-DAM MEMBRANE FROM EDGE TO 24" INSIDE EXTERIOR WALL LINE OF BUILDING IN AREAS W/HISTORY OF ICE � � •. <br /> THAN 18"ABOVE FLOOR OR GROUND, (3)TOP EDGE LESS THAN 36"ABOVE FLOOR, &(4)LESS THAN OR EQUAL TO 36"HORIZONTAL OF A FORMING AT EAVES U � ,� <br /> WALKWG SURFACE (EXCEPTION#3) (R905.2.2)ASPHALT SHINGLE MIN SLOPE 4:12 M � <br /> -DECORATIVE GLASS EXCEPTION:2:12 SLOPE OK W/DOUBLED UNDERLAYMENT SHINGLE FASHION �""� M � <br /> f,� ALL GLAZiNG IN RAILINGS (R905.2.5)ASPHALT SHINGLE MIN.4 FASTENERS, MIN 3/4"INTO(OR THROUGH)SHEATHING � M � <br /> Q ENCLOSURES& FACING WALLS OF SHOWERS, BATNS, WHIRLPOOLS, ETC.,WHEN LOWER EDGE OF GLASS LESS THAN 60"ABOVE (R905.7.2) 16"WOOD SHINGLES MIN. SLOPE 3:12(3 3/4" MAX. EXPOSURE IF LESS THAN 4:12) ' W <br /> � STANDING OR WALKING SURFACE(EXCEPTION#5) (R905.8.2)WOOD SHAKES MIN. SLOPE 3:12 (MIN. 4:12 RECOMMENDED) � <br /> E -GLAZING LESS THAN 60" HORIZONTAL FROM EDGE OF HOT TUB,WHIRLPOOL, OR BATH (R905.3.2)CLAY/CONCRETE TILE MIN. SLOPE 2 1/2:12, DOUBLE UNDERLAYMENT IF LESS THAN 4:12 � <br /> z WALLS & FENCES LESS THAN 60" FROM POOLS/HOT TUBS&LESS THAN 60"ABOVE GROUND (R903.2.2)CRICKET REQUIRED AT CHIMNEYS&OTHER PENETRATIONS GREATER THAN 30"WIDE <br /> � GLAZING LESS THAN OR EQUAL TO 3 FT. HORIZONTALLY FROM STAIR, LANDING, OR RAMP "�r' <br /> � -INTERVENING RAIL WITHSTANDING 50PSF LOAD&34-36"ABOVE WALKING SURFACE LOW-SLOPE ROOFING O <br /> -' -GLAZING GREATER THAN 18" HORIZONTALLY FROM GUARDRAIL OR HANDRAIL (R905.9.1} BUILT-UP ROOFS MIN. SLOPE 1/4"VERTICAL TO 12" HORIZONTAL <br /> � -SOLID WAL� BELOW GLASS TO 34-36"ABOVE WALKING SURFACE (R905.9.3) INSTALL AMI &TO APPROPRIATE ASTM STANDARDS O <br /> � GLAZING LESS THAN 60" HORIZONTAL OF BOTTOM STAIR NOSING&LESS THAN 60" HIGH (R903.4)DRAIN OVER EDGES OR WSTALL DRAINS AT EACH LOW POINT � <br /> � -GLAZING GREATER THAN 18" HORIZONTALLY FROM GUARDRAIL OR HANDRAIL (R903.4.1)SECONDARY DRAINS OR SCUPPERS REQUIRED 2"ABOVE LOW POINT OF ROOF <br /> � -SOLID WALL BELOW GLASS TO 34-36"ABOVE WALKING SURFACE <br /> o DECKS& BALCONIES - <br /> o �R308.6)SKYLIGHTS AND SLOPED GLAZING (TABLE 301.5) EXTERIOR BALCONIES &DECKS LIVE LOAD 40 PSF <br /> � <br /> � (R308.6.2) SKYLIGHTS MAY BE TEMPERED, HEAT-STRENGTHENED, LAMINATED,WIRED, OR APPROVED RIGID PLASTICS (R311.5.1) EXTERIOR LANDINGS, DECKS, BALCONIES, STAIRS POSITIVE ANCHOR(NO TOENAILS)TO STRUCTURE TO RESIST VERTICAL& <br /> � (R308,6.8) MIN.4"CURB IF ROOF SLOPE LESS THAN 3/12 UNLESS OTHERWISE SPECIFIED AMI LATERAL FORCE. <br /> �.. <br /> E (R507.1}DECKS.WOOD FRAMED DECKS SELF-SUPPORTING IF CONNECTION NOT VERIFIABLE <br /> � (SECTION R310)EMERGENCY ESCAPE AND RESCUE OPENINGS (R507.2.1) LEDGER CONNECTIONS MIN 1/2" LAG SCREWS OR BOLTS ��qQ _ ED <br /> zo (R310.1) ESCAPE & RESCUE OPENINGS REQUIRED FOR ALL SLEEPING ROOMS, BASEMENTS& HABITABLE ATTICS LAG SCREWS/BOLTS MIN. HOT-DIPPED GALVANIZED OR STAINLESS TABLE R402.1.1 TABLE R402.1.3 <br /> -BASEMENTS LESS THAN OR EQUAL TO 200 SQ. FT.&ONLY FOR MECHANICAL EQUIPMENT. DECK LEDGERS NOT TO BE SUPPORTED ON MASONRY VENEER INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT EQUIVALENT U-FACTORS a <br /> = EACH BASEMENT SLEEPING ROOM REQUIRES ITS OWN OPENING (R507.3)COMPOSITE DECKING LABELED FOR COMPLIANCE W/ASTM D 7032 <br /> U WINDOW SILL HEIGHT MAX. 44"ABOVE FLOOR CLIMATE ZONE 5 AND MARINE 4 CLIMATE ZONE 5 AND MARINE 4 QAI�N N <br /> Z MIN. 20"WIDE &24" HIGH, 5.7 SQ. FT. CLEAR OPENING AREA FIREBLOCKING: REQUIRED LOCATIONS <br /> � -5.0 SQ. FT. OK IF DIRECT GRADE LEVEL ACCESS (R302.11) IN COMBUSTIBLE CONSTRUCTION, FIREBLOCKING SHALL BE PROVIDED TO CUT OFF BOTH VERTICAL AND HORIZONTAL b , T�QFM(�{I��I�I'I <br /> o FENESTRATION U-FACTOR 0.30 FENESTRATfON U-FACTOR 0.30 <br /> po SECURITY BARS REQUIRED INTERIOR QUICK-RELEASE HARDWARE CONCEALED DRAFT OPENINGS AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE <br /> � WINDOW WELLS MIN. 9 SQ. FT. &36" MIN. HORIZONTAL DIMENSION ROOF SPACE. FIREBLOCKING SHALLL BE PROVIDED IN WOOD-FRAMED CONSTRUCTION IN THE FOLLOWING LOCATIONS: SKYLIGHT b U-FACTOR 0.50 SKYLIGHT U-FACTOR 0.50 <br /> �, PERMANENT LADDER REQUIRED IF LESS THAN 44"BELOW GRADE 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR <br /> � LADDER MAY PROJECT 6" INTO REQUIRED WELL SPACE STAGGERED STUDS AS FOLLOWS; b e <br /> GLAZED FENESTRATION SHGC ' NR CEILING U-FACTOR 0.026 <br /> �E 1.1.VERTICALLY AT THE CEILING AND FLOOR LEVELS. <br /> � (SECTION R408) UNDER-FLOOR SPACE (CRAWLSPACE) 1.2. HORIZONTALLY AT WTERVALS NOT EXCEEDING 10' k <br /> o- CEILING R-VALUE 49 WOOD FRAME WALL U-FACTOR 0.056 <br /> z (R408.1)VENTILATION 2.AT INTERCONNECTIONS BETWEEN CONCEALEQ VERTICAL AND HORIZONTAL SPACES SUCH AS SOFFITS, DROP CEILINGS <br /> ¢ EXTERIOR OPENINGS UNDER FLOORS EXCEPT FOR BASEMENTS AND COVED CEILINGS. WOOQ FRAME WALL g'm'n R-VALUE 21 int MASS WALL U-FACTOR 0.056 <br /> _ (5R408.1 &2)VENT OPENINGS WITHIN 3'OF EACH CORNER 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES <br /> c� (R408.2)OPENINGS SCREENED OR GRATED UNDER STAIRS SHALL COMPLY WITH SECTION R302.7. MASS WALL R-VALUE � 21/21 FLOOR U-VALUE 0.029 <br /> Q (R408.2) MIN.AREA 1 SQ. FT. PER 300 SQ. FT. UNDER-FLOOR AREA 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT CEILING AND FL�OR LEVEL WITH APPROVED <br /> � -REDUCTION TO 1 SQ. FT./1500 SQ. FT. OK W/CLASS 1 VAPOR RETARDER MATERIAL TO RESIST THE FREE PASSAGE OF FLAME. MATERIAL FILLING SHALL MEET ASTM E 136 REQUIREMENTS. FLOOR R-VALUE 30 BELOW-GRADE WALL U-FACTOR 0.042 <br /> p {R408.3} NO VENTILATION REQUIRED IF VAPOR RETARDER, INSULATED WA�LS &SPACE CONDITIONED OR CONTINUOUS MECHANICAL (R302.11.1) 1.2" NOMINAL LUMBER. <br /> � VENTILATION 2. 2 THICKNESSES OF 1" NOMINAL LUMBER WITH BROKEN LAP JOINTS ��m a <br /> C� � � BELOW-GRADE WALL R-VALUE 10/15/21 int+TB Nonfenestration U-factors shall be obtained from measurement,caiculation <br /> 'a� (R408.4)ACCESS. ACCESS OPENING THROUGH FLOOR, MIN. 18"X 24".ACCESS OPENING THROUGH WALL, MIN. 16"X 24" 3. (1)THICKNESS OF 23/32"WOOD STRUCTURAL PANELS AND JOINTS BACKED <br /> 3 or an approved source or as specified in Section R402.1.3. <br /> � BY 23/32"WOOD STRUCTURAL PANELS <br /> � {R602.9) FOUNDATION CRIPPLE WALLS DRAFTSTOPPING SLAB R-VALUE&DEPTH 10,2 ft. <br /> � <br /> Y FOUNDATION CRIPPLE WALLS SHALL BE FRAMED OF STUDS NOT SMALLER THAN THE STUDDING ABOVE.WHEN EXCEEDING 4' IN HEIGHT, (R302.12) FLOOR/CEI�ING DRAFTSTOPPED IF GREATER THAN 1,000 SQ. FT. (OPEN WEB TRUSSES OR CEILING SUSPENDED <br /> � SUCH WALLS SHALL BE FRAMED OF STUDS HAVING THE SIZE REQUIRED FOR AN ADDITIONAL STORY. FROM FLOOR FRAMING) For SI: 1 foot=304.8 mm, ci=continuous insulation, int= intermediate framing. � <br /> 3 CRIPPLE WALLS SUPPORTING BEARING WALLS OR EXTERIOR WALLS OR INTERIOR BRACED WALL PANELS AS REQUIRED IN SECTION (R302.12.1) MATERIAL MIN. 1/2" GYPSUM OR 3/8"WOOD PANELS a Q <br /> -g R403.1.2 AND R602.10.9.1 WITH A STUD HEIGHT LESS THAN 14°SHALL BE SHEATHED ON AT LEAST ONE SIDE WITH A WOOD STRUCTURAL R-values are minimum. U-Factors and SHGC are maximums. When insulation is installed in a cavity which � <br /> L PANEL THAT IS FASTENED TO BOTH THE TOP AND BOTTOM PLATES IN ACCORDANCE WITH TABLE R602,3(1), OR THE CRIPPLE WALLS SMOKE A�ARMS is less than the label or design thickness of the insulation, the compressed R-value of the insulation <br /> � SHALL BE GONSTRUCTED OF SOLID BLOCKING.ALL WALLS CRIPPLE SHALL BE SUPPORTED ON CONTINUOUS FO�TINGS, FOUNDATIONS. (R314.1) NFPA 72 SYSTEMS W/DETECTORS OK IN LIEU OF SMOKE ALARMS from Appendix Table A101.4 shall not be less than the R-value specified in the table. _ <br /> .o NFPA 72 SYSTEMS REQUIRE CENTRAL STATION MONITORING&BECOME PERMANENT FIXTURE OF THE PROPERTY b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. � � <br /> � R401.3 DRAINAGE EXCEPTION: SYSTEMS THAT SUPPLEMENT A COMPLIANT ALARM SYSTEM <br /> � SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT DOES {R314,3) REQUIRED IN EACH SLEEPING ROOM&ADJOINING AREA � „ „ Q,� <br /> � NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS.THE GRADE SHALL FALL MIN. 1 DETECTOR EACH STORY INCLUDING BASEMENTS 10/15/21 +TB means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation <br /> `�' A MINIMUM OF 6"WITHIN THE FIRST 10'. INTERCONNECT SO ACTIVATION OF 1 SETS OFF ALL ALARMS on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the � <br /> � EXCEPTION:WHERE LOT LINES, WALLS, SLOPES OR OTHER PHYSICAL BARRIERS PROHIBIT 6"OF FALL WITHIN 10', DRAINS OR SWALES (R314.4) POWER FROM BUILDING WIRING PLUS BATTERY BACKUP basement wall at the interior of the basement wall. "10/15/21 +TB"shall be permitted to be met with � <br /> v SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE . IMPERVIOUS SURFACES WITHIN 10'OF THE BUILDING EXCEPTION: BATTERY POWER ALONE OK FOR REMODEL WHERE NO FINISHES REMOVED&NO ATTIC OR CRAWL AVAILABLE FOR WIRE R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior � <br /> as <br /> FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 PERCENT AWAY FROM THE BUILDING. or exterior of the wall. "TB"means thermal break between floor slab and basement wall. <br /> � CARBON MONOXIDE ALARMS d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1 <br /> E R302.7 UNDER-STAIR PROTECTION (R315.1) REQUIRED OUTSIDE SLEEPING AREAS IN NEW DWELLINGS W/FUEL-FIRED APPLIANCES OR W/ATTACHED GARAGES <br /> o ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER-STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE (R315.3)EXISTING DWELLING SAME AS NEW WHEN WORK REQUIRING PERMIT PERFORMED e There are no SHGC requirements in the Marine Zone <br /> c? ENCLOSED SIDE WITH 1/2"GYPSUM BOARD REQUIRED LIGHT&VENTILATION DATE: 09-01-16 <br /> = jR311.7) STAIRWAYS. i <br /> (R303.1) HABITABLE ROOM NATURAL LIGHT OPENINGS MIN. 8°/a OF FLOOR AREA The second R-value applies when more than half the insulation is on the interior of the wall. <br /> � (R311.7.1)WIDTH. STAIRWAYS SHALL NOT BE LESS THAN 36" IN CLEAR WIDTH. HANDRAILS SHALL NOT PROJECT MORE THAN 4 1/2"ON DESIGNED:TR <br /> o EXCEPTION:ARTIFICIAL LIGHT @ 6 FOOTCANDLES OK W/MECHANICAL VENTILATION � <br /> i-- EITHER SIDE OF THE STAIRWAY. k <br /> (R311.7.2)THE HEADROOM IN STAIRWAYS SHALI. BE NOT LESS THAN 6'-8" MEASURED VERTICALLY. (R303.1}HABITABLE ROOM NATURAL VENTILATION OPENINGS MIN. 4%OF FLOOR AREA For single rafter-orjoist-vaulted ceilings, the insulation may be reduced to R-38 DRAWN: TR <br /> E EXCEPTION:APPROVED MECHANICAL VENTILATION SYSTEM W/0.35 ACH=AIR CHANGES PER HOUR <br /> a EXCEPTION: EDGE OF FLOOR PASSING OVER STAIR OK TO PROJECT 4 3/4" m <br /> ; � (R303.3) BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING Int. (intermediate framing}denotes standard framing 16 inches on center with headers insulated with a min of R-10. JOB NO: 2016-31 <br /> � (R311.7,5.1) RISERS. THE RISER HEIGHT SHALL NOT BE MORE THAN 7 3/4". OPEN RISERS ARE ALLOWED BUT DO NOT PERMIT THE AREA IN WINDOWS OF NOT LESS THAN 3 SQ. FT., ONE-HALF OF WHICH TO BE OPENABLE - <br /> , PASSAGE OF A 4 DIAMETER SPHERE. EXCEPTION: FAN TO OUTSIDE 50CFM INTERMITTENT OR 20 CFM CONTINUOUS.VENTILATION AIR SHALL BE EXHAUSTED DIRECTLY TO � Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from thls insulatipn requirement SHEET: <br /> ° (R311.7.5.2)TREADS. THE TREAD DEPTH SHALL NOT BE L;ESS THAN 10". OUTSIDE <br /> N (R311.7.5.1&R311.7.5.2) MAX. DIFFERENCE BETWEEN GREATEST&SMALLEST RISER HEIGHT OR LARGEST&SHORTEST TREAD DEPTH 3/8" (R1501.1) BATH FAN MAY NOT DISCHARGE INTO ANY PART OF ATTIC <br /> N (R311.7.5.3) NOSINGS.A NOSING PROJECTION NOT LESS THAN 314"AND NOT MORE THAN 1 1/4". (R303.2) EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE EQUIPPED WITH SOURCE SPECIFIC AND WHOLE HOUSE <br /> o EXCEPTION;A NOSING PROJECTION (S NOT REQUIRED WHERE THE TREAD DEPTH IS NOT LESS THAN 11" VENTILATION SYSTEMS DESIGNED AND INSTALLED AS SPECIFIED IN SECTIONS R1507 AND R1508. � � <br />