Search
Reece Construction Company Inc 4/24/2018
>
Contracts
>
Capital Contract
>
Reece Construction Company Inc 4/24/2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2019 10:44:28 AM
Creation date
4/26/2018 10:20:12 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Reece Construction Company Inc
Approval Date
4/24/2018
Council Approval Date
3/28/2018
Department
Public Works
Department Project Manager
Richard Hefti
Subject / Project Title
Water Main Improvement S
Public Works WO Number
UP3664
Tracking Number
0001163
Total Compensation
$1,866,805.49
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
Reece Construction Co 9/12/2018 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
Reece Construction Company 8/29/2019 Change Order 2
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
275
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF EVERETT SPECIAL PROVISIONS <br /> Provide valve stem extension in accordance with COE Standard Drawing No. 504. <br /> 9-30.3(8) Tapping Sleeve and Valve Assembly <br /> Revise the last sentence of 9-30.3(8) to read as follows: <br /> Provide all stainless steel tapping sleeves, Romac SST, Romac SSTIII, or City <br /> approved equal. <br /> 9-30.5 Hydrants <br /> Delete first paragraph of 9-30.5 and substitute the following: <br /> 1 Provide fire hydrants with ANSI 125 flanged connection conforming to AWVVA C502. <br /> Provide Mueller "Super Centurion No. 250", American Flow Control "Waterous Pacer <br /> No. WB67", or City approved equal. <br /> 9-30.5(2) Hydrant Dimensions <br /> Delete last sentence of first paragraph of 9-30.5(2) and substitute the following: <br /> Provide hydrants having two 2-1/2 inch hose nozzles and one 4-1/2 inch pumper <br /> nozzle. The 4-1/2 inch pumper nozzle shall be National Thread and fitted with a <br /> 5-inch STORZ fitting. <br /> Delete last sentence of second paragraph of 9-30.5(2) and substitute the following: <br /> Paint hydrants with two coats of high gloss Caterpillar yellow, Luxite 6100-516, <br /> Rost-Oleum 7448, or City approved equal. Paint the port caps with two coats of <br /> high gloss black enamel paint. <br /> 9-30.5(4) Hydrant Restraints <br /> Revise the first paragraph of 9-30.5(4) to read as follows: <br /> Provide either mechanical joint restraint system in accordance with 9-30.5(6) of <br /> these Special Provisions, or field lock gaskets for hydrant restraint. <br /> 9-30.6 Water Service Connections (2-inches and Smaller) <br /> 9-30.6(1) Saddles <br /> Revise 9-30.6(1) to read as follows: <br /> Provide Romac, Ford, Mueller, or City approved equal single strap ductile iron, <br /> bronze, brass, or stainless steel service saddle with C.C. (AWWA tapered) thread <br /> for 3/4-inch and 1-inch services. <br /> Provide Romac, Ford, Mueller, or City approved equal double strap ductile iron, <br /> bronze, brass, or stainless steel service saddle with I.P. thread for 2-inch services. <br /> All materials shall meet the requirements of AWWA C800-05. <br /> 9-30.6(2) Corporation Stops <br /> Revise 9-30.6(2) to read as follows: <br /> Provide Ford FB600 Series, or City approved equal, corporation stops for 3/4-inch <br /> and 1-inch services. <br /> All materials shall meet the requirements of AWWA C800-05. <br /> 9-30.6(4) Service Fittings <br /> ' Revise third paragraph to read as follows: <br /> Provide either compression fittings, or stab type fittings using internal grip and 0 <br /> ring seal, for polyethylene pipe. <br /> 9-30.6(5) Meter Setters <br /> Delete the second, third and fourth paragraphs of 9-30.6(5) and substitute the <br /> following: <br /> Provide A.Y. McDonald 62-212WWDD33-15, or City approved equal, meter setter <br /> for 3/4-inch and 1-inch metered service. Provide Ford 70 Series copper setter <br /> Water Main Improvement S Division 9—MATERIALS January 29, 2018 <br /> ' WO No.—UP3664 SP—177 <br />
The URL can be used to link to this page
Your browser does not support the video tag.