Laserfiche WebLink
LEGEND <br /> REFER TO SHEET EO FOR SYMBOLS AND ABBREVIATIONS. <br /> REFER TO SHEET E506 FOR FIRE ALARM ABBREVIATIONS. <br /> I <br /> I ' <br /> --- t - - - --:� -- <br /> i ' <br /> I <br /> GENERAL NOTES <br /> SV5 FR <br /> JWWF Vs VS UV5-6A TAMPER 2 <br /> SP5-6 WE PS W5-6A HI/LO AIR 1 <br /> F W5-6A WE PRESSURE <br /> 5 <br /> SV5-6 WE ISO TAMPS 1 4 <br /> SV5-6 WE PRESSURE I <br /> REFERENCE DRAWING <br /> B <br /> CONSTRUCTION NOTES <br /> CONNECT EXISTING HI/LO AIR SWITCH DEVICE TO <br /> NEW FIRE ALARM SYSTEM, UTILIZING EXISTING <br /> CONDUIT. REPLACE WIRING. <br /> w <br /> I �PROVIDE OS&Y TYPE TAMPER SWITCH. CONNECT TL <br /> i NEW FIRE ALARM SYSTEM UTILIZING EXISTING <br /> INFRASTRUCTURE. PROVIDE ADDITIONAL CONDUIT <br /> I AND CONDUCTORS AS REQUIRED. <br /> i <br /> o PROVIDE WALL POST INDICATOR TYPE -AMPER <br /> SWITCH. CONNECT TO NEW FIRE ALARM SYSTEM <br /> ? __ UTILIZING EXISTING INFRASTRUCTURE. PROVIDE <br /> o ADDITIONAL CONDUIT AND CONDUCTORS AS <br /> REQUIRED. <br /> I <br /> I <br /> PROVIDE WATERFLOW PRESSURE SWITCH. PROVIDE <br /> CONNECTION TO NEW FIRE ALARM SYSTEM, <br /> UTILIZING EXISTING INFRASTRUCTURE. PROVIDE <br /> -C ADDITIONAL CONDUIT AND CONDUCTORS AS <br /> REQUIRED. <br /> I �PROVIDE WATERFLOW PRESSURE SWITCH WITH <br /> ADJUSTABLE DELAY ON EXISTING ALARM CHECK <br /> VALVE ASSEMBLY. PROVIDE BALL VALVE WITH <br /> i TAMPER SWITCH UPSTREAM OF WATERFLOW SWTICH. <br /> PROVIDE CONNECTIONS TO NEW FIRE ALARM <br /> SYSTEM. PROVIDE CONDUIT AND CONDUCTORS AS <br /> REQUIRED. SEE DETAIL 1/E506-2 FOR <br /> - INSTALLATION DETAILS. <br /> 6. COORDINATE WITH FIRE SPRINKLER CONTRACTOR <br /> FOR INSTALLATION OF DEVICES AND ANY VALVE OR <br /> PIPING MODIFICATIONS AS REQUIRED. <br /> STORAGE ARE4 <br /> SEE SHEET 1E261 <br /> FOR CONTINUATION <br /> 1 C <br /> .1 <br /> MATCH LINE - FOR CONTINUATION SEE SHT 1E267 1 13 9 5 <br /> I � ✓A <br /> 1E260 1E261 1E262 1E26 <br /> C <br /> 1E264 1E265 1E266- IE267 <br /> PARTIAL PLAN VIEW S A Z A N E <br /> SCALE: 1/8"=1•—D" N G R O U P KEY PLAN <br /> 600 Stewart St.. Ste 1400 SCALE: NONE N <br /> Seattle.Washington 98101 ` DENOTES DRAWING NOT IN SET <br /> IFC SUBMITTAL �� Tel 206.267.1700 8' 4' c 4 16' <br /> OCTOBER 14, 2016 Fax 206.267.1701 r = = 1 <br /> SAZAN#444-1564 SCALE: 1/8"=!'—D' <br /> SW REVSM BY APPNWED QME Sy. Sr APPAm 64E ACCEPTABILITY MDK" '14.16 PARTIAL FIRE ALARM PLAN cuR��W 640474 `Yv 10.14.16 <br /> A FIRE ALARM REWIRE CO SUPPORT 19419798 MDK KER MNH 04,D4.16 THIS DCONO!MID/OR/1Y / ` PECffIC47lOn'S APPROYEO KER _34.16 SHED �/�B EVERETT nRE PANEL REPLACEMENT W2640474 SAZAN/ZO 10.14.16 �O ,�� APPe w XPt. WE NDN 4.3416 'QLE EVERETT TIP -;`JEL REPLAG=:' 1 E263 <br /> `R °.34'6 BUILDING 40-05 C v <br /> au: <br /> 04.16 <br /> 1a,<x1e ;W- 104.04.16 ELECTRICAL MASTEk COL. A-C/1-5 EVERETT, WA. 40-005-1E263 <br />