My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-05 2018-09-24
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-05
>
3003 W CASINO RD BLDG 40-05 2018-09-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 8:10:58 AM
Creation date
4/27/2018 8:31:12 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-05
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
136
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIRE ALARM ABBREVIATIONS LEGEND <br /> POINT NUMBER/ZONE TYCO COMMENT/BOEING DESCRIPTION FACP o01NT/COMMENTS/GRID LOC. <br /> SV5-1 WF PRESSURE WATERFLOW PRESSURE W/DE AY E/15 ALT SECONDARY OR ALTERNATE ELEVATOR RECALL REFER TO SHEET EO FOR SYMBOLS AND ABBREVIATIONS. <br /> BEAM DET BEAM DETECTOR <br /> SV5-1 TAMPER SPRINKLER RISER OS&Y VALVE E/15 CDR COMPUTER/NETWORK/DATA/IDF ROOM <br /> COL COLUMN <br /> SV5 WF ISO TAMPER WATERFLOW ISOLATION TAMPER E/15 COMM FAIL COMMUNICATION FAILURE <br /> SV5-2 WF PRESSURE WATERFLOW PRESSURE W/DELAY A/15 CTRL CONTROL <br /> CW CATWALK <br /> SV5-2 TAMPER SPRINKLER RISER OS&Y VALVE A/15 DMPR DAMPER <br /> DO DUCT SMOKE DETECTOR <br /> SV5-2 WF ISO TAMPER WATERFLOW ISOLATION TAMPER A/15 DIESEL DIESEL <br /> SV5-3 WF PRESSURE WATERFLOW PRESSURE W/DELAY E/9 FP FIRE PUMP <br /> ELEC ELECTRICAL; ELECTRICAL ROOM <br /> SV5-3 TAMPER SPRINKLER RISER OS&Y VALVE E/9 ELEV ELEVATOR GENERAL NOTES <br /> EPP EXCESS PRESSURE PUMP <br /> SV5-3 WF ISO TAMPER WATERFLOW ISOLATION TAMPER E/9 FACP FIRE ALARM CONTROL PANEL 1. RACEWAY CONFIGURATION AND ROUTING SHOWN ARE <br /> SV5-4 WF PRESSURE WATERFLOW PRESSURE W/DELAY A/9 ELEV FF HAT LIGHT FIRE FIGHTER HAT LIGHT IN A ELEVATOR DIAGRAMMATIC AND DO NOT NECESSARILY REPRESENT <br /> FLR FLOOR ACTUAL INSTALLATION. FINAL PATHS SHALL BE <br /> SV5-4 TAMPER SPRINKLER RISER OS&Y VALVE A/9 FM FIRE MAIN VALVE DETERMINED BY ELECTRICAL CONTRACTOR. <br /> HEAT HEAT DETECTOR <br /> SV5-4 WF ISO TAMPER WATERFLOW ISOLATION TAMPER A/9 INTDEV INTERFACE DEVICE, MONITORING OR CONTROL <br /> ISO ISOLATION VALVE 2. ELECTRICAL CONTRACTOR SHALL PROVIDE ENCLOSURE(S) <br /> AND POWER. <br /> SV5-5 WF PRESSURE WATERFLOW PRESSURE W/DELAY E/3 KITCHEN KITCHEN <br /> L BATT LOW BATTERY <br /> SV5-5 TAMPER SPRINKLER RISER OS&Y VALVE E/3 L FUEL LOW FUEL(FIRE PUMP DIESEL TANK IS BELOW 507 FILLED) <br /> SV5-5 WF ISO TAMPER WATERFLOW ISOLATION TAMPER E/3 LBY LOBBY <br /> LRD LOW RATE DISCHARGE <br /> SV5-6 WF PRESSURE WATERFLOW PRESSURE W/DELAY A/5 MAN PULL MANUAL PULL STATION <br /> MECH MECHANICAL ROOM <br /> SV5-6 TAMPER SPRINKLER RISER OS&Y VALVE A/5 NAC NOTIFICATION APPLIANCE CIRCUIT OR POWER SUPPLY <br /> SV5-6 WF ISO TAMPER WATERFLOW ISOLATION TAMPER A/5 OS&Y OUTSIDE SCREW AND YOKE VAVLE <br /> P PRESSURE TYPE <br /> UV5-2A WF PRESSURE WATERF-DW PRESSURE SWITCH A/16 PD PUMP DISCHARGE VALVE; PRESSURE TYPE W/DELAY <br /> PH PENTHOUSE REFERENCE DRAWINGS <br /> UV5-2A HI/LO AIR PRESSURE SWITCH A/16 PIV POST INDICATOR VALVE <br /> POWER FAIL FACP POWER FAILURE <br /> UV5-2A TAMPER SPRINKLER VALVE A/16 PREACT PREACTION SYSTEM <br /> UV5-3A WF PRESSURE WATERROW PRESSURE SWITCH E/9 PRI PRIMARY <br /> PS PUMP SUPPLY VALVE <br /> UV5-3A HI/LO AIR PRESSURE SWITCH E/9 PWR POWERRF ROOF <br /> UV5-3A TAMPER SPRINKLER VALVE E/9 RLY RELAY <br /> UV5-4A WF WATERFLOW SWITCH A/9 SEC SECTION VALVE <br /> SHUNT SHUNT TRIP <br /> UV5-4A TAMPER SPRINKLER VALVE A/9 I <br /> SMK SMOKE DETECTOR CONSTRUCTION NOTES <br /> STK STALL <br /> UV5-6A WF PRESSURE WATERFLOW PRESSURE SWITCH A/5 STROBE STROBE, HORN OR ANY NOTIFICATION DEVICE <br /> SUPPR SUPPRESSION 1. ALL WIRING SHALL BE DRESSED AND TRAINED IN A <br /> UV5-6A HI/LO AIR PRESSURE SWITCH A/5 SUPV SUPERVISORY WORKMANLIKE MANNER. <br /> SV SPRINKLER VALVE 2. ALL WIRES SHALL BE LABELED WITH WIRE ID ON BOTH <br /> UV5-6A TAMPER SPRINKLER VALVE A/5 TAMPER TAMPER SWITCH ENDS OF WIRE. <br /> SMK 0 FACP SO ABOVE FACP STAIR 1 E/9.5 TL300 TL300 TYCO COMMUNICATION DEVICE <br /> TRBL TROUBLE 3. ALL INCOMING POWER WIRING SHALL BE IN CONDUIT. <br /> MAN PULL ® FACP MAN PULL AT STAIR 1 E/9.5 UV UNIT VALVE <br /> VLV VALVE 4. ALL PENETRATIONS TO FACP AND TELECOMMUNICATIONS <br /> WF WATERFLOW SWITCH ENCLOSURES SHALL BE IN ACCORDANCE WITH <br /> ZN ZONE MANUFACTURER'S INSTRUCTIONS. <br /> PROVIDE PHENOLIC LABELS, INSTALL AND CENTER ON <br /> UPPER ENCLOSURE DOOR WITH POWER CIRCUIT ID. <br /> SYSTEM DEVICE POINTS LIST PROVIDE LABEL THAT READS: "FACP NETWORK <br /> SCALE: NONE E506 ENCLOSURE". (WHITE LETTERING AND RED BACKGROUND). <br /> CONFIGURE FIRE ALARM CONTROL PANEL TO <br /> TRANSMIT PRIMARY AND SECONDARY <br /> RE ALARM ANALOG PHONE LINE (PRIMARY COMMUNICATIONS) COMMUNICATIONS IN A SIMULTANEOUS MANNER IN <br /> CONTROL PANEL — — — — ACCORDANCE WITHNFPA72-2010/13 26.6.3.2.1.4(8)(7). <br /> 6 (FACP) "TELCO � PROVIDE CONDUIT WITH PULLSTRING. <br /> DEMARC MONITORED BY TYCO AND <br /> g SIGNAL SENT TO CENTRAL <br /> BOEING FIRE DEPARTMENT <br /> 12"X12" <br /> 2 12"PHONE DX FIRE ALARM CABLING ANALOG PHONE LINE (SECONDARY COMMUNICATIONS) <br /> FACP EVi-FA-40-05 0PRIMARY AND <br /> (BY FIRE ALARM VENDOR) SECONDARY PHONE PRIMARY CONNECTION: PHONE LINE TO Q <br /> LINE JACKS TELEPHONE BACKBOARD/DEMARC. s SMOKE R, <br /> (BY ELECTRICAL (CABLING BY BOEING IT) PULL STAATION,TION, -BOEING SERVICES REQUEST MUST BE MADE <br /> WATER FLOW& REQUESTING:TWO ANALOG VOICE (FLAT BUSINESS LINE) <br /> CONTRACTOR) TAMPER SWITCHES JACK/CONNECTIONS. AFTER JACKS ARE INSTALLED, <br /> ANALOG LINES MUST BE REQUESTED TO CONNECT <br /> HORNS, BELLS ANALOG VOICE JACKS. <br /> SECONDARY CONNECTION: PHONE LINE Q &STROBES <br /> TO TELEPHONE BACKBOARD/DEMARC. <br /> (CABLING BY BOEING IT) <br /> FIRE ALARM SYSTEM COMMUNICATIONS DETAIL �2 FIRE ALARM SYSTEM SIGNAL AND COMMUNICATIONS OVERVIEW S A Z A N <br /> SCALE: NONE EE�06 <br /> SCALE: NONE E5`06 G R O U P <br /> 600 Stewart St., Ste 1400 <br /> Seattle,Washington 98101 <br /> IFC SUBMITTAL Tel 206.267.1700 <br /> OCTOBER 14,2016 Fax 206.267.1701 <br /> SAZAN N 444-1564 <br /> SYM REV6pN 81 APPRDVED DATE SYM REVISION BY APCR�: �.�.. DPAWN SUHIREE -REN'REVSION SYMSDL — pATF <br /> ACCEPTABILITY zo 06.13.16 FIRE ALARM DETAILS W2640474 10.14.16 <br /> EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN ZO 10.74.16 THIS OEONI MID/OR <br /> EVERETT X KA 06.13.16 SHEET <br /> t �� �.ew SPECIFp1TpN S APPROVED <br /> ® `' V ^T'E EVERETT FIRE PANEL REP:ACEMENT E506 <br /> wPRwEn er DEPT. wTc KA 06.73.16 CJ U I <br /> iNECNED / <br /> BUILDING 40-05 0B N0 W2640474 <br /> 0""p1E A`PROOE ELECTRICAL MASTER EVERETT.WA.ONO ND. 40-O5-E506 <br />