My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-05 2018-09-24
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-05
>
3003 W CASINO RD BLDG 40-05 2018-09-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 8:10:58 AM
Creation date
4/27/2018 8:31:12 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-05
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
136
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br /> REFER TO SHEET EO FOR SYMBOLS AND ABBREVIATIONS. <br /> REFER TO SHEET E506 FOR FIRE ALARM ABBREVIATIONS. <br /> GENERAL NOTES <br /> 1. WET RISER/PIPING CONFIGURATION SHOWN IS <br /> DIAGRAMMATIC AND DOES NOT NECESSARILY REPRESENT <br /> ANY ACTUAL INSTALLATION. <br /> REFERENCE DRAWINGS <br /> TO SPRINKLERS <br /> WATERFLOW <br /> PRESSURE SWITCH <br /> WITH BUILT-IN <br /> RETARD/DELAY <br /> (ALARM) <br /> i� <br /> I CONSTRUCTION NOTES <br /> I PROVIDE VALVE ON ALARM LINE WITH LOCKABLE HANDLE <br /> AND PIPING UPSTREAM OF ALARM SWITCH AS SHOWN. <br /> L TO WATER D�::- PROVIDE TAMPER SWITCH ON ALARM LINE VALVE AS <br /> MOTOR GONG SHOWN. PROVIDE CONNECTION TO NEW FIRE ALARM <br /> WATER PRESSURE GAUGE �I SYSTEM UTILIZING EXISTING INFRASTRUCTURE. PROVIDE <br /> (SYSTEM PRESSURE) _ J L — — — ADDITIONAL CONDUIT AND CONDUCTORS AS REQUIRED. <br /> rALARM LINE 2 WATERFLOW <br /> (OPEN) I SHUT-OFF ISOLATION i 3� PROVIDE WATERFLOW PRESSURE SWITCH WITH <br /> q� VALVE TAMPER SWITCH ADJUSTABLE DELAY AS SHOWN. PROVIDE CONNECTION TO <br /> (SUPERVISORY) ( NEW FIRE ALARM SYSTEM UTILIZING EXISTING <br /> BY-PASS LINE INFRASTRUCTURE. PROVIDE ADDITIONAL CONDUIT AND <br /> F_ — — — CONDUCTORS AS REQUIRED. <br /> 4. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR <br /> CHECK VALVE RETARD INSTALLATION OF SWITCH(ES),VALVE AND ALL PIPING <br /> e I I DRAIN CHAMBER MODIFICATIONS. <br /> WATER PRESSURE GAUGE CHECK VALVE <br /> (SUPPLY PRESSURE) OPEN I I (CLOSED) <br /> OS&Y TAMPER <br /> SWITCH WATER BY-PASS <br /> (SUPERVISORY) TEST VALVE (CLOSED) STRAINER DRIP <br /> qI CUP <br /> OS&Y VALVE <br /> CONTROL (OPEN) <br /> CHECK <br /> VALVE <br /> DRAIN <br /> WATER SUPPLY PIPE S A z A N <br /> GROUP <br /> 600 Stewart St., Ste 1400 <br /> SPRINKLER RISER WATERFLOW FR-SSURE SWITCH W/DELAY DETAIL Seattle,Washington 98101 j <br /> SCALE: NONE E506--2 IFC SUBMITTAL40Tel 206.267.1700 <br /> OCTOBER 14,2016 Fax 206.267.1701 <br /> SAZAN%444-1564 <br /> WN IXTESUBfIRF CURk':v'HfVSgN SYMBOL OWTE <br /> SYN KV19)k BY APPROVED DATE SYM REVSpR 9Y APPRWED DATE ACCEPTABILITY FIRE ALARM SYSTEM DETAILS W2640474 - 10.14.16 <br /> EVERET'FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 10.1416Rq 1N6 DESGk AND/OR `N S."SPEC"I"E"Is APPROVED <br /> BOE//V�i �L "°PR°�D DAY °EPt- °"TE ME EVERETT FIRE PANEL REPLACEMENTCHE-ED E506-2 <br /> K'Fau BUILDING 40-05 °B ND <br /> ,a+anDie POOR ELECTRICAL MASTER EVERETT, WA.D N0 45-005-E506-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.