Laserfiche WebLink
Pag 3 of 4 <br /> -Building of Type IIB, sprinklered construction story limitations (Table 503 and Section 504.2). <br /> Group B: 5 stories <br /> Group S-1: 4 stories <br /> Group F-1: 3 stories <br /> Group A-2: 3 stories <br /> -Building height in feet limitations (Table 503 and Section 504.2). <br /> 75 feet(Buildings are 88 feet in height with the highest occupied floor level 71 feet above the lowest <br /> level of fire department vehicle access, therefore not OK). <br /> Building allowable area: <br /> -Varies based on height of actual building in stories and the occupancies contained in the building <br /> (worse case actual examples for each story level condition shown). <br /> Containing Group F-1/three story maximum (Table 503, Section 506: <br /> Story 1: Group F-1, 40,000 square feet. <br /> Story 2: Group S-1, 35,000 square feet. <br /> Story 3: Group B, 40,000 square feet. <br /> Total: 115,000 square feet. <br /> F-1 At: 15,500 +Is: 31,000=Aa: 46,500 x 3 (stories)= 139.500 square feet allowed, therefore OK <br /> based on nonseparated use provisions at Section 302.3.1. <br /> Containing Group F-1/four story maximum(Table 503, Section 506: <br /> Story 1: Group F-1, 30,000 square feet. <br /> Story 2: Group B, 2,145 square feet. <br /> Story 2: Group A-2, 2,041 square feet. <br /> Story 2: Group F-1, 25,814 square feet. <br /> Story 3: Group B, 25,000 square feet. <br /> Story 4: Group B, 30,000 square feet. <br /> Total: 115,000 square feet. <br /> Story 2 sum of the ratio calculation: (2,145 /69,000=0.03) + (2,041 / 28,500 = 0.07) + (25,814/46,500 <br /> =0.56) = 0.60 less than 1.0 therefore OK. <br /> F-1 At: 15,500 +Is: 31,000=Aa: 46,500 x 3 (stories)= 139.500 square feet allowed, therefore OK <br /> based on separated use provisions at Section 302.3.2. No occupancy separations required based on <br /> anticipated approval of Item G-32 by ICC membership and Group A-2 accessory use area less than 10 <br /> percent in accordance with the provisions of Section 302.2. <br /> Containing Group F-1/five story maximum (Table 503, Section 506: <br /> Story 1: Group F-1, 30,000 square feet. <br /> Story 2: Group B, 9,246 square feet. <br /> Story 2: Group F-1, 5,000 square feet. <br /> Story 2: Group S-1,15,754 square feet. <br /> Story 3: Group B, 30,000 square feet. <br /> Story 4: Group B, 30,000 square feet. <br /> Story 5: Group B, 30,000 square feet. <br /> Total: 115,000 square feet. <br /> Story 2 sum of the ratio calculation: (9,246/69,000=0.13) + (5,000/46,500= 0.11) + (15,754/52,500 <br /> = 0.30) = 0.54 less than 1.0 therefore OK. <br /> F-1 At: 15,500+Is: 31,000+If. 7,750=Aa: 54,250 x 3 (stories) = 162,750 square feet allowed, <br /> therefore OK based on separated use provisions at Section 302.3.2. No occupancy separations required <br /> based on anticipated approval of Item G-32 by ICC membership. <br /> 8/5/2005 <br />