Laserfiche WebLink
WIRING DIAGRAM SPECIFICATIONS <br /> Input Voltage: 16.5-27.5 VDC <br /> Typical N.O,Initiatirg <br /> °eV"�s Standby Current: 450µA Max <br /> Alarm Current: 450 µA Max <br /> Max. No.Of Devices per <br /> See lotes:1,2,ana 4 <br /> Communication Circuit: 255 (Will support all <br /> Se���� devices in alarm simul- <br /> c-, �t7 �10KR�sistor) taneously) <br /> s����e {_� {_� SLCline Operating Temperature: -31 - 151�F (-35-66�C) <br /> ooc <br /> See No�e 3 Typicol N,C.Supervisory 0-95% RH <br /> Devices <br /> RemoteLED LED Pulse Modes <br /> (ODGonep <br /> SeeN�, Normal: 9 second interval <br /> g ` � y ° ` z ` Trouble: LED is off <br /> ;' s M°°=�',���� � Alarm: 2 second interval <br /> ' �g � EOL <br /> _ ���'e= � _� p <br /> z7� -'���g�5� �� ���a (10K Resislor) <br /> $�� g �W%3P <br /> �y��i�M�ay$ � 9 G 9 S s E 2 t <br /> 7 41;� <br /> �` ia � 3 <br /> NOTES ORDERING INFORMATION <br /> 1. Maximum 25 52 resistance per conductor/50 S2 per Part Number Description <br /> circuit. 70-407008-001 Addressable Contact Input <br /> 2. Max. #14 AWG (1.5 mm=)wire. Device N.O. <br /> Min. #18 AWG (0.75 mmz)wire. 70-407008-002 Addressable Contact Input <br /> 3. Referto Control Panel Manual forwiring specifica- Device N.C. <br /> tion. 70-411001-005 Package of 10 End-of-Line <br /> 4. Maximum 10 VDC @ 1 mA. Resistors <br /> 5. All wiring is power limited and supervised. <br /> 6. This module will not support 2-wire smoke detec- <br /> tors. ARCHITECTURAL/ENGINEERING <br /> 7. Rating of LED circuit: 26 VDC Max., 7mA Max. If SPECIFICATIONS <br /> not used leave terminals open circuit. For specifications request a copy of the Architectural/ <br /> 8. N/O and N/C initiating device circuits are NFPA Engineering Specification Disk: Available from Kidde- <br /> Class B/Style B. Fenwal Inc. Marketing Department. <br /> 9. AI N/C is intended for non-fire applications. <br /> ALARM TEST <br /> Any or all Als can be tested by command from the com- <br /> patible control unit. Results of the test may be printed out <br /> at the system printer. <br /> INSTALLATION <br /> The AI can be mounted in a North American 2-1/2-in. (64 <br /> mm) deep, 1-gang box, or standard 4-in. square box, <br /> 1-1/2-in. (38 mm) deep with cover. The terminal block <br /> will accept#14, 16 and 18 AWG wire (1.5 mm2, 1.0 mm2, <br /> 0.75 mm2). <br /> SmartOne�is a registered trademark of Kidde-Fenwal,Inc. <br /> This literature is provided for informational purposes only. KIDDE-FENWAL,INC. <br /> assumes no responsibility for the producYs suitability for a particular application.The prod- � • � � • <br /> uct must be properly applied to work correctly. <br /> If you need more information on this product,or if you have a particular problem or ques- <br /> tion,contact KIDDE-FENWqL,INC.,Ashland,MA 01721.Telephone:(508)881-2000. <br /> KIDDE-FENWAL INC. <br /> F-74-214 Rev AD OO 2008 Kidde-Fenwal Inc. Printed in USA 400 MAIN STREET,ASHLAND,MA pt721 <br /> TEL:(508)881-2000 FAX:(508)881-8920 <br /> www.Kidde-Fenwal,com <br />