Laserfiche WebLink
� <br /> Inteltigent Peripheral Devices <br /> Quad Tnterface Module (4-Input / 4-0utput) <br /> Model FDCI0422 <br /> ARCHITECT AND ENGINEER SPECLFICATIONS <br /> • Four (4) inputs/four (4) outputs via one (1) address <br /> • Status indication via light-emitting diode (LED) screen of all input/output functions <br /> • Input lines can be supervised for open, short and ground-fault conditions <br /> • Supports'Class A'and 'Class B' input-circuit wiring <br /> • Polarity insensitive utilizing SureWireT""technology � <br /> • Microprocessor-controlled signal evaluation <br /> • Two-wire installation � ' , <br /> • Power supply via C-Net module �`� <br /> • Communication via C-Net <br /> ■ Individual addressing �w� <br /> • Mounts in one (1) electrical back box � <br /> • Optional 4-inch and 5-inch square back boxes � � <br /> • Four(4) relay outputs '_. `" . , <br /> • Restriction of Hazardous Substances (RoHS compliant) <br /> • Electronic address programming is easy and dependable <br /> • Easy front-end access to programming port and wiring terminals <br /> • Model 8720/DPU programs and verifies device's address,as well as performs test funetionality <br /> • QUt268A Listed [for direct air-duct use); <br /> �ULC Pending; CSFM Approved <br /> Product Overview Specifications <br /> The four(4)input!(4)output interface module Model FDC10422 is used for the connection of up to two(2) <br /> (Model FDCI0422)from Siemens—Fire Safety is independent'Class A'or four(4)independent'Class B;dry <br /> designed to provide the means of interfacing direct and N.O configurable contacts. Input lines can be <br /> shorting devices to the Cerberus PRO fire-alarm supervised for open,short and ground-fault conditions <br /> control panels(FACPs). (depending on end-of-line[EOL]termination resistor and <br /> Model FDC10422,which contains microcomputer-chip class configuration). <br /> (SureWire)technology and is polarity insensitive, Inputs can be independently configured,via the FACP,for <br /> achieves the state of an'intelligent device'through its Alarm, Trouble,Supervisory or Status zones. <br /> highly advanced method of address programming and Model FDCI0422 has four(4)programmable outputs with <br /> supervision—combined with its sophisticated,bi- four(4)potential free-latching-type'Form A(dry)relay <br /> directional FACP communication. contacts for fire-control installations. <br /> The relays and contact device inputs for Model The FACP's C-NET module provides supervised,power-limited <br /> FDC�0422 are controlled at the same address. From power supply for Model FDd0422. The four(4)input 1(4) <br /> the FACP,the relays and input contacts can be output interface module provides status indication per LED <br /> controlled as a separate function. The relay is typicalfy for each input/output,plus one(1)LED for general device <br /> used where control or shunting of external equipment status. Also included with Model FDCT0422 are four(4)EOL <br /> is required. devices(470 ohms},as well as three(3)separators to <br /> Model FDCI0422 is designed to monitor Normally separate power-limited wiring from non-power-limited <br /> Open(N.0)or Norma►ly Closed(N.C)dry contacts. wiring. <br /> Each interface module reports the status of the(N.0) <br /> or(N.C}to the FACP. <br /> CerberusT"" PRo 9905 <br /> Fire Safety&Security Products uad Interface Module <br /> Answers for infrastructure S 1 E M E N S <br />