<br /> SYMBOL LEGEND MATERIALS LEGEND ABBREVIATIONS GENERAL NOTES p
<br /> � �
<br /> 4=1► X BUILDWG AND WALL o LWEAR 4 FOOT , ,.+�5.�:���� EARTH, DIRT, UNDISTURBED 1. CONTRACTOR SHALL INVESTIGATE AND VERIfY LOCATIONS OF (,�
<br /> XX XX xx SECTIONS & AND L LENGTH STRUCTURAL, MECHANICAL AND ELECTRICAL ELEMENTS ALONG WITH OTHER =
<br /> �-' � AT LB LAG BOLT EXISTING CONDITIONS PRIOR TO BEGINNING OF ANY WORK. �
<br /> o LINEAR 8 F00T �p-�=�� EqRTH, DIRT, COMPACTED AB ANCHOR BOLT LEN LENGTH �
<br /> � �_- ADJ ADJACENT LF LINEAL FEET 2t CONTRACTdR IS TO VERIFY ALL DIMENSIONS AND CONDIiIONS SHOWN
<br /> . � DETAIL AFF ABOVE FINISHED FLOOR LL LIVE LOAD ON THE DRAWINGS AND SHALL BE RESPONSIBLE FOR THE JOINING OF HIS �
<br /> vX xX Xx 0 LINEAR 12 FOOT o•a,qaeoao„8vea STONE, GRAVEL, POROUS FILL AGG AGGREGATE LWR LOWER
<br /> WORK TO THE WORK OF OTHER TRADES. ANY DISCREPANCIES BEiWEEN �
<br /> � X �� � ALT ALTERNA E MATL MATERIAL THE EXISTING CONDITIONS AND CONTRpCT DOCUMENTS SHOULD BE CA�LED O
<br /> � REFERENCE TO DETAIL LINEAR 16 FOOT %//////////////� BRICK, COMMON ANCH ANCHOR;ANCHORAGE MAX MAXIMUM TO THE ATfENTION Of THE ARCHITECT OR ENGINEER. IN THE EVENT OF C3
<br /> �x xx xx �\` J j p�p,N APA AMERICAN'PLYWOOD ASSOCIATION MB MACHINE BOLi SUCH A DISCREPANCY, THE MOST STRINGENT REQUIREMENT(S) WILL
<br /> e LWEAR WALL WASHER 3 F00T APPD APPROVED MBR MEMBER GOVERN THE SCOPE Of WORK. �
<br /> XX SIIIIII�4S4,S�fSISIS�54� CERAMIC TILE APPROX APPROXIMATE MEf METAL O
<br /> ROOM NUMBER _e ASTM AMERICAN SOCIETY MFR MANUFACTURE(R) 3. THE CONTRACTOR SHALC BE RESPONSIBLE FOR SAFETY 1N THE AREA �
<br /> XX LINEAR WASHER 4 FOOT OF TESTING MATERIALS MIN MINIMUM
<br /> • � CONCRETE: CAST-IN-PLACE, PRECAST OF WORK IN AC�ORDANGE WITH ALL SAFETY LAWS AND CODES. W
<br /> ' ' ' MiSC MISCELU+NEOUS CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ALL SECURITY
<br /> � WALL MOUNTED LINEAR 3 FOOT BTWN BEPNEEN MT MOUNT(ED) (ING) REQUIREMENTS AND REGULATIONS WITHIN THE AREA OF WORK: �
<br /> XX DOOR NUMBER BLDG BUILDWG MTL METAL-
<br /> Q�U`�P�SZR,RSZSISUIRR INSULATION: BATT, LOOSE, FILL BLANKET gLKG BLOCKING �
<br /> � WALL MOUNTED LINEAR 4 FOOT BOT BOTfOM N NORTH (COORDINATE) 4: CONTRACTOR SHALL INSURE THAT ALL WORK CONFORMS TO/WITH ALL Cn
<br /> O WINDOW lYPE ��� INSUlATION: RIGID NF NEAR FACE APPLICABLE BUILDING CODES AND STATE REGUfATIONS. -
<br /> C CHANNEL NIC NOT W CONTRACT
<br /> � ROUND PENDANT CB CATCH BASIN N0. NUMBER 5. CONTRACTOR SNALL KEEP AREAS UNDER CONSTRUCTION CLEAR Of
<br /> � WALL iYPE %%/%///%////i ALUMINUM CC CENTER TO CENTER NOM NOMINAL DEBRIS CAUSED'BY DEMOLITION AND SHALL STORE CONSTRUCTION
<br /> CEM CEMENT NTS NOT TO SCALE
<br /> : � 2'X4'TROUGH CF CUBIC FPEf - MATERIALS AND EQUIPMENT IN AREAS DESIGNATED BY THE CONSTRUCTION
<br /> �/%/./,/././%/,/%/ BRASS, BRONZE, COPPER � MANAGER. IF THE CONTRACTOR HAS ANY QUESTIONS OR COMMENTS
<br /> % \ ' CJ CONTROL JOINT OA OVERALL ABOUT CLEANWG THROUGHOUT THE COURSE OF WORK, THEY WILL BE
<br /> � r - - GRID�GRID BUBBLE AND CL CENTER LINE OC ON CENTER(S) ADDRESSED BY THE CONSTRUCTION MANAGER. CONTRACTOR IS REQUIRED
<br /> � MTL CEILING GRID W/ LAY-IN CLG TILES /�����/��j MEfAL, STEEL, IRON CLR CLEAR(ANCE)' OD OUTSIDE DIAMETER
<br /> L'�.f CENI`ERLINE -i—r
<br /> COL COLUMN OF OUTSIDE FACE TO PROVIDE A DAILY CLEAN-UP ON THE JOB SITE.
<br /> --------------- CONSTRUCTION ABOVE OR BELOW EXIST. 2'X4' LAY-IN FLUORESCENT LIGHT COMP COMPRESS(ED) (ION) OPG OPENING
<br /> BEYOND OR BEHIND � FIXTURE '. PIASTER: SAND, CEMENT, GROUT CONC CONCRETE OPP OPPOSITE 6. REPETITIVE FEATURES NOT EULLY SHOWN OR NOTED ON THE DRAWWGS
<br /> CONN CONNECTION SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL
<br /> DIMENSION DIMENSION LINE PLASTER: GYPSUM WALL BOARD CONST CONSTRUCTION P PAINT
<br /> 4, w RELOCATED EXIST. 2'X4' LAY-W CONT CONTINUOUS, CONTINUE PAR PARALLE� 7.DIMENSIONS-0N DRAWINGS ARE TAKEN TO THE FACE OF MASONRY
<br /> � � CONTR CONTRACT(OR) PCC PRECAST CONCRETE
<br /> a Z FLUORESCENT IIGHT FIXTURE � AND OR CONCRETE'WALLS, FACE OF STUDS, OR TO THE CENTERLINE OF
<br /> "- w ��/ J I WOOD: FINISH CTSK COUNTERSUNK PCF POUNDS PER CUBIC FOOT COLUMNS UNLESS OTHERWISE NOTED ON THE DRAWINGS.
<br /> o � CY CUBIC YARD(S) PERF PERFOR4TE(D)
<br /> � � �� FLOURESCENT FIXTURE(RECESSED, D DIAMETER PERIM PERIMETER
<br /> �"=� WODD: ROUGH PL PLATE 8. DOOR OPENINGS ARE 6° FROM A6JACENT WALLS dR CENTERED IN THE
<br /> SURFACE) DBL DOUBLE p �pM PLASTIC LAMINATE ROOM, UNLESS SHOWN OR NOTED OTHERWISE ON THE DRAWWGS.
<br /> �-� bEMOL DEMOLISH; DEMOLITION PNL PANEL
<br /> ��---' FLAG NOTE FOR SPECIFIC .------"'"�- WOOD: INTERRUPTED BLOCKING DEP DEPRESSED PREST PRESTRESS(ED)
<br /> INCANDESCENT/F�OURESCENT FIXTURE DIA DIAMETER 9. PARTITIONS SHALL RUN FULL HEIGHT, FROM FLOOR TO STRUCTURE
<br /> CONSTRUCTION DIRECTION �;( PRF PREFORMED
<br /> (CAN) ,, � ��; DIAG DIAGONAL PSF POUNDS PER SQUARE FOOT ABOVE, UNLESS SNOWN OR NOTED QTHERWISE ON THE DRAWWGS.
<br /> �r��n PLYWOOD: SMALL SCALE DIM DIMENSION PSI POUNDS PER SQUARE INCH
<br /> � GENERAL NOTE FOR DL DEAD LOAD PT POINT 10. PLANS WHICH APPEAR AS BACKGROUNDS ON CNIL, STRUCTURAL,
<br /> NON-SPECIFIC INfORMATION �,t� TRACK LIGHTING (SURFACE) DN DOWN PVC PO�YVINYL CHLORIDE PIPE MECHANICAL AND ELECTRICAL DRAWINGS ARE FOR THE PURPOSE ONLY OF
<br /> ������ PLYWOOD: LARGE SCALE DS DOWNSPOUT PWD PLYWOOD ILLUSTRATING GENERAL PLAN CONFIGURATION. SUCH BACKGROUNDS
<br /> DWG DR4WING SNALL NOT BE USED FOR PORTIONS OF THE WORK QTHER THAN THAT
<br /> �J FLDOR DRAIN E EAST (COORDINATE) R RADIUS (CURVATURE) PERTAINWG TO SHE TITLE OF EACN SHEET. REFER TO THE APPROPRIATE
<br /> EA ' EACH R RISER SHEET FOR EACH SPECIfIC PORTION OF THE WORK.
<br /> EMERGENCY PHONE • ' ' ' WALL TYPE: CONCRETE E8 EXPANSION BOLT REF REFERENCE REFER TO
<br /> � DOOR - NEW EF EACH FACE REINF REWFORCE(D) QNG)
<br />- X � 11. THE GENERAL CONTRACTOR AND RESPECTNE SUBCONTRACTORS SHALL
<br /> EJ EXPANSION JOINT REQ REQUIRE(D) (ING}
<br /> ■ F L O O R B O X %�/.�/f�/y/�//r/; WALL TYPE CONCRETE MASONRY UNIT (CMU) EL EIEVAiION REV REVISION(S), REVISED B E R E S P O N S I B L E F O ft T H E C O O R D I N A T I O N O f T H E E N T I R E S C O P E O F
<br /> ELEV ELEVATION RH RIGHT HAND WORK. THE fNTIRE SET OF CONTRACT DOCUMENTS SHALL BE REFERRED
<br /> � 2-0"x2'-0" SUSPENDED ES EACH SIDE RO ROUGH OPENING TO IN DETAII FOR COORDINATION OF SPECIFIC REQUIREMENTS. THE
<br /> CEILING GRID �'�—'�i,•4—. WALL TYPE: WOOD STUD E4 EqUAI GENERAL CONTRACTOR SHALL REVIEW THE ENTIRE SET OF DOCUMENTS
<br />� EW EACH WAY SQ S4UARE FOR WORK OF VARIOUS TRADES WHICH MAY BE INCLUDED ON OTHER
<br /> EXIST EXISTING SECT SOUTH (COORDINATE) DISCIPLINE DRAWINGS OR-SPECIFICATION SECTIONS fOR EXAMPLE:
<br /> WALL TYPE EXISTING EXP EXPOSED SECT SECTION ELECTRICAL WORK INDICATED ON MECHANICAL SHEETS BUT NOT SHOWN
<br /> EXT EXTERIOR ON TNE ELECTRICAL-0RAWINGS. THE CONTRACTOR.SNALL PROVIDE ALL
<br /> 2'-0"x4'-0" SUSPENDED Sf SQUARE FEE� WORK REQUIRED TO COMPLETE ALL SYSTEMS INDICATED IN ALL i
<br /> CEILING GRID WALL lYPE: NEW FAS fASTEN(ER) SHi SHEET DOCUMENTS WHETHER OR NOT THE WORK IS INDICATED IN THE lYPICAL
<br /> Fp FLOOR DRNN SIM SIMILAR
<br /> FCO FLOOR CLEAN OUT SS STAINLESS STEEL DISCIPLINE LOCATION.
<br /> --� WAI.L TYPE: GLASS FF FACTORY FINISH SQ SQUARE
<br /> FF FINISHED FLOOR ST STRUCTURAL TEE 12, CONSTRUCTION MANAGER TO INDICATE STAGING AREAS WHERE THE
<br /> GWB CEILING OR SOFFIT FGR FINISH GRADE STD STANDARD CONTRACTOR MAY STORE SALVAGEp MATERIALS TO BE REUSED IN LATER
<br /> FH FIRE HYDRANT STL STEEL PHASES OF THIS PROJECT AND WHERE MATERIALS TO BE STAGED BY
<br /> FW FINISH(ED) STR STRUCTURAL BOEING ARE T0 BE LOCATED:
<br /> FND FOUNDATION SYM SYMMETRY,SYMMETRICAL
<br /> FEO- FIRE EXTWGUISHER FOC FACE OF CONCRETE SYS SYSTEM 13. SYMBOLS SNOWN QN MATERIALS LIST ARE NOT ALWAYS USED IN THE
<br /> FOF FACE OF FINISH DR4WINGS. CONTRACTOR TO VERIFY ALL EXISTING MATERIAL AND SEE
<br /> FOIC fURNISHED BY OWNER/ T&B TOP AND BOTTOM CONSTRUCTION NOTES.FOR MATERIAL CAlLOUTS.
<br /> " SUPPLY AIR DIFFUSER INSTALLED BY CONTRACTOR T&G TONGUE AND GROOVE
<br /> FO FINISHED OPENING TC TOP OF CURB
<br /> � FRT FIRE-RETARDANT TREATED ELEVATION 74. SEE MECNANICAL AND ELECTRICAL DRAWINGS FOR WORK OF THOSE
<br /> RETURN AIR GRILLE Ff FOOT TEMP TEMPORARY TRADES AND OTHERS WHICH DAMAGE EXISTING BUILDMG COMPONENTS AND
<br /> FTG FOOTING THK THICK(NESS) FINISHES, REQUIRE PATCHING, REPAIR AND REfINISHING TQ SEAMLESS
<br /> FUT FUTURE TOC TOP OF CONCREfE CONDITION. REPAIR WALL OR SURFACE TO BE REPAINTED TO THE NEXT
<br /> RETURN AIR GRILLE TOL TOLERANCE CORNER PROJECTION OR BREAK IN SURfACE.
<br /> ' GA GAGE TOM TOP OF MASONRY
<br /> �''-'� GALV GALVANIZED TOS TOP OF STEEL
<br /> ii i FAN POWERED AIR TERMINAL GC GENERAL CONTRACTOR TS STRUCTURAL TUBE
<br /> �---� GI GALVANIZED IRON TYP lYPICAL
<br /> GR GRADE U8C UNIFORM BUILDING
<br /> • fIRE SPRINKLER HEAD GT GROUT
<br /> � CODE
<br /> �I-� EXIT SIGN HDWO HARDWOOD UL UNDERWRI7ERS' LABEL
<br /> UON UNLESS OTHERWISE
<br /> HG HIGH GRADE NOTED
<br /> G SMOKE DETECTOR HM HOLLOW ME7AL UPR UPPER
<br /> HOR NORIZONTAL
<br /> HS HIGH STRENGTH VB VAPOR BARRIER
<br /> � EMERGENCY LIGHT HT HEIGHT VERT VERTICAL
<br /> � ROOF/ACCESS DOOR ID INSIDE DIAMETER W WEST (COORDINATE)
<br /> ID INSIDE DIMENSION W WIDE FLANGE
<br /> IF INSIDE FACE W WIDTH, WIDE
<br /> W INCH
<br /> WCl INCLUDED(D) (WG) W%0 WITHOUT
<br /> JT JOINT �'F WELDED WIRE FABRIC �oaea
<br /> � . � � REGISTERED
<br /> . . . ' . . . . . . . . . .. . . . �,_ - ARCHITECT�.
<br /> K KIP(S)
<br /> � � � � �� .� � � � - � � . �� � � KO �KNOCK OUT .� � � � . �t�t�l����.a���t t�� 6,[ .0 r��-X- GREGG R.KIRKENDALL
<br /> . � � � . � . . . .. . . .. .. . . � 7U.V.JrI �U�1A 7�Pf»Et:.7CII�E�17T .. STAIE OF WASHINGTON � �i
<br /> , ���,tQn,w��ntn�o��so��
<br /> ACCEPTABILITY MEW�� �� 03 13 14 $ue'rmt . . - � � cuRaerR�a�nsioN rnaeo� on� g..
<br />_ svM a�visior+ ar APPROYED onh srM e�visioN �' ���o �^T� E°` '""s"��pr mis oesicN nno/oa ABBREVIATIONS 8c SYMBOLS LEGEND O 03/13/14
<br /> 0 ISSUE FOR CONSTRUCTION � MEW GRK 03/73/74 � � � � � � � GRK - � 03 13 14 � - � � �
<br /> /��/ SPECIFlCATION IS APPROVED � � SHEEr . '�'
<br /> � . � � � � � . . . ��//����,���,B_� OE,��� a.�E�'�n��o APPROVED BY � DEPT. DATE� �RKN� . D3 73 14 n�E NEW 4O—Z� BUILDING . ^�� �I
<br /> . . ' Y . .. � � �: `I
<br /> HJ313I H K
<br /> APPROVED BUILDING 40-037 � ��B N�. v COMP N0. "���
<br />- 15477651
<br /> zwaP"�~ -pPP OV DWG N0. N I
<br /> ARCHITECTURAL MASTER EVERETT, WA 40-037-0GO I