My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-53 2020-10-22
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-53
>
3003 W CASINO RD BLDG 40-53 2020-10-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2020 9:49:25 AM
Creation date
4/27/2018 3:47:49 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-53
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
169
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> • Boein 40-31 Phase 1 Jul 12,2012 <br /> Ta s HVAC-2 <br /> � Coii section ressure dro in H20 0.109 0.976 <br /> Coil ri in wei ht Ib 228.8 1216.5 <br /> Coil installed wei ht Itr 288.5 1547.4 <br /> To or sin le coil d wei ht Ib 103.0 538.5 <br /> Middle or bottom coil d wei ht Ib 125.8 678.1 <br /> Leavin d bulb F 70.89 54.00 <br /> Leavin wet bulb F - 53.90 <br /> Enterin d bulb F 20:00 78.00 <br /> Enterin wet bulb F - 67.00 <br /> Fluid type Propylene Water <br /> I col <br /> Coil fluid ercenta e % 20.00 100.00 <br /> Enterin fluid tem erature F 180.00 45.00 <br /> Leavin fluid tem erature F 150.00 60.81 <br /> Fluid tem erature rise F - 15.81 <br /> Fluid tem erature dro F 30.00 - <br /> Standard fluid flow rate m 90.83 122.00 <br /> Fluid ressure dro ft H20 16.69 7.70 <br /> Fluid veloci ft/s 5.02 3.29 <br /> Fluid volume al 7.17 39.58 <br /> Sensible ca aci MBh - 635.47 <br /> Total ca acit MBh 1324.54 967.54 <br /> Air mixin section <br /> Position #1 <br /> Section len th in 48.000 <br /> Section wei ht Ib 1079.4 <br /> Openin 1 back-airflow cfm 24000 <br /> O enin 1 front-airFlow cfm 24000 <br /> O enin 1 to -airtlow cfm 24000 <br /> O enin 1 back-area sq ft 18.59 <br /> Openin 1 front-area sq ft 58.43 <br /> O enin 1 to -area s ft 18.59 <br /> O enin 1 back-face veloci fUmin 1291 <br /> O enin 1 to -face velocit ft/min 1291 <br /> O enin 1 back- ressure dro in H20 0.294 <br /> O enin 1 to - ressure dro in H20 0.294 � <br /> O enin 1 back total ressure dro in H20 0.294 <br /> O enin 1 to total ressure dro in H20 0.294 <br /> Back inlet pe Unducted <br /> To inlet t e Unducted <br /> Greatest ent PD in H20 0.294 <br /> Filter condition User <br /> specified <br /> PD <br /> Filter airflow cfm . 24000 <br /> Filter area s ft 100.00 <br /> FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 5 of 26 <br /> Insfalled by Others <br />
The URL can be used to link to this page
Your browser does not support the video tag.