My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-53 2020-10-22
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-53
>
3003 W CASINO RD BLDG 40-53 2020-10-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2020 9:49:25 AM
Creation date
4/27/2018 3:47:49 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-53
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
169
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 34 of 51 I 08/24/2012 <br /> . a <br /> CD50 AMCA LICENSED PERFORMANCE DATA <br /> CD50 PRESSURE LIMITATIONS <br /> s 60" The CD50 may be used in systems with total pressures exceeding 3.5" by reducing <br /> � (7524) <br /> damper section width as indicated.Example:Maximum design total pressure of 8.5"w.g. <br /> � would require CD50 damper with maximum section width of 36"(914). <br /> ° �•� Pressure limitations shown above allow maximum blade deflection of 1/180 of span on <br /> �� (7219) <br /> N 60"(1524)damper widths. Deflections in other damper widths(Iess than 4S"[1219])at <br /> higher pressures shown will result in blade deflection substantially less than 1/180 of <br /> Q36" span. <br /> (914) <br /> oQmC4 Ruskin Company certifies that the CD50 <br /> Z4.. oe�mn� shown herein is licensed to bear the AMCA <br /> 3 (610) �T��� Seal. The ratings shown are based on tests <br /> � p�R and procedures performed in accordance with <br /> �x 12•� AMCA Publication 511 and comply with the <br /> � (305) p�R requirements of the AMCA Certified Ratings <br /> 3 4 5 6 7 8 9 10 11 72 13 Program.The AMCA International Certified <br /> Maximum Design Total Static Pressure Ratings Seal applies to Air Pertormance and <br /> Inches Water Gage Air Leakage. <br /> Pressure/ Leakage,L/s/mz(ft'/minlft?) DAMPER WIDTH(INCHES) 1 JN.W.G. -4 IN.W:G. 81N.W.G <br /> Class . : Requiceil�R�ting ;; �tended`Ranges;j4pYJ; 12" 305 IA I II <br /> 9"(0.25 kPa) 4"(1.0 kPa) 8"(2A kPa) 12"(3.0 kPa) 24" 610 IA I II <br /> 1A 3(15.2) N/A N/A N/A 36" 914 IA I NA <br /> 1 4(20.3) 8(40.6) 11 (55.9) 14(71.1) 48" 1219 IA I NA <br /> 2 10(50.8) 20(102) 28(142) 35(178) 60"(1524) IA I NA <br /> 3 40(203) 80(406) 112(569) 140(711) <br /> Leakage testing conducted in accordance with AMCA Standard 500- dampers.Air leakage is based on operation between 50°F to 104°F. <br /> D-98. Torque applied holding damper closed, 5 in. Ibs./sq. ft. on All data corrected to represent standard air density 0.075 Ibs/ft'. <br /> opposed blade dampers and 7 in. Ibs./sq. ft. on parallel blade <br /> VELOCITY VS. PRESSURE DROP <br /> � 100 500 7000 5000 10D00 <br /> 2 3 � b 7 89 2 3 4 6 7 89 <br /> 1.0 1.0 <br /> 0.9 0.9 <br /> 0.8 0.8 <br /> 0.7 12 X 12 0.7 <br /> � 0.6 ,4 X 12 0.6 <br /> 0.5 0.5 <br /> � 0.4 ' 12X48 0.4 <br /> 0.3 %� 24 X 24 0.3 <br /> (� <br /> � <br /> W 0.2 , 6 % 36 0.2 <br /> 2 <br /> Z <br /> a o.� o.i <br /> p .oe .ae <br /> � .as .�8 <br /> o .o� .m <br /> W .O6 .06 <br /> Q' <br /> � .OS .OS <br /> N <br /> N .04 .04 <br /> W <br /> Q' <br /> n. .03 .03 <br /> .02 .02 <br /> .Ot <br /> 2 3 4 6 7 8 9 2 3 � 6 7 89 <br /> t00 500 t000 5000 t000D <br /> FACE VELOCITY-FEET/MINUTE <br /> AMCA FIG.5.3 <br /> CD50 sizes 12 x 12,24 x 24,48 x 12, 12 x 48,36 x 36(305 x 305,610 x 610, 1219 x 305,305 x 1219,914 x 914) <br /> All data corrected to represent standard air at a density of 0.075 ibs/ft'. <br />