My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-12 2018-09-20
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-12
>
3003 W CASINO RD BLDG 45-12 2018-09-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 1:08:21 PM
Creation date
4/30/2018 8:39:21 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-12
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Seatronics,Inc. Boeing 45-012 Building—EDC Static Test Facility-Phase 2 Section 1 <br /> Job: 111008 Fire Alarm System Data Submittal Manual Page 3 <br /> C. FIRE SPRINKLER SYSTEM MONITORING DEVICES -CONTINUED <br /> 2. SUPERVISORY CONDITIONS-VALVE TAMPER <br /> 2.1 ACTIVATION OF ANY FIRE SPRINKLER SYSTEM VALVE TAMPER DEVICE OR PIV <br /> CLOSURE, SHALL CAUSE THE FOLLOWING TO OCCUR: <br /> A. ILLUMINATE THE YELLOW"SUPERVISORY" INDICATOR ON THE FAP. <br /> B. DISPLAY MESSAGE ON THE CONTROL PANEL LCD DISPLAY INDICATING LOCATION <br /> INFORMATION FOR THE DEVICE THAT WAS ACTIVATED. <br /> C. TRANSMIT A"SUPERVISORY" SIGNAL(WITH POINT INFORMATION)TO THE REMOTE <br /> MONITORING STATION. <br /> D. AIRPLANE VESDA SYSTEMS <br /> 1. ALARM CONDITIONS—HIGH LEVEL SMOKE DETECTION <br /> 1.1 ACTIVATION OF A HIGH LEVEL SMOKE ALARM (LEVEL 3)ON THE VESDA SMOKE <br /> DETECTOR SHALL CAUSE THE FOLLOWING TO OCCUR: <br /> A. ILLUMINATE THE RED"ALARM" INDICATOR ON THE FAP. <br /> B. DISPLAY MESSAGE ON THE CONTROL PANEL LCD DISPLAY INDICATING LOCATION <br /> INFORMATION FOR THE DEVICE THAT WAS ACTIVATED. <br /> C. VESDA GRAPHICS SYSTEM—AIRPLANE POSITION DISPLAYED IN RED WITH PC <br /> SPEAKERS EMITTING "HIGH ALARM" SOUND. "HIGH ALARM" MESSAGE DISPLAYED. <br /> D. ACTIVATE LOCAL VESDA AUDIBLE&VISUAL ALARM DEVICE FOR THE AFFEGI`ED <br /> SYSTEM ONLY. <br /> E. AFTER 60 SECOND TIME DELAY,ACTIVATE AIRPLANE POWER SHUNT TRIP <br /> BREAKER(S). <br /> F. NOTE: PRESSING THE POWER SHUTDOWN"SAVE"SWITCH BEFORE THE 60 <br /> SECOND COUNTDOWN TIMER HAS EXPIRED WILL STOP SHUTDOWN TIMER. <br /> RELEASING THE SWITCH WILL RESTART THE TIMER FROM 60 SECONDS. THE FAP <br /> MUST BE RESET TO CLEAR THIS CYCLE. <br /> G. TRANSMIT AN "ALARM" SIGNAL(WITH POINT INFORMATION)TO THE REMOTE <br /> MONITORING STATION. <br /> 2. ALARM CONDITIONS—MANUAL STATION <br /> 2.1 ACTIVATION OF A MANUAL STATION FOR THE AIRPLANE VESDA SYSTEM SHALL CAUSE <br /> THE FOLLOWING TO OCCUR: <br /> A. ILLUMINATE THE RED"ALARM" INDICATOR ON THE FAP. <br /> B. DISPLAY MESSAGE ON THE CONTROL PANEL LCD DISPLAY INDICATING LOCATION <br /> INFORMATION FOR THE DEVICE THAT WAS ACTIVATED. <br /> C. VESDA GRAPHICS SYSTEM—AIRPLANE POSITION DISPLAYED IN RED WITH PC <br /> SPEAKERS EMITTING"HIGH ALARM" SOUND. "HIGH ALARM" MESSAGE DISPLAYED. <br /> D. ACTIVATE LOCAL VESDA AUDIBLE &VISUAL ALARM DEVICE FOR THE AFFECTED <br /> SYSTEM ONLY. <br /> E. IMMEDIATELY ACTIVATE AIRPLANE POWER SHUNT TRIP BREAKER(S). <br /> F. TRANSMIT AN "ALARM" SIGNAL(WITH POINT INFORMATION)TO THE REMOTE <br /> MONITORING STATION. <br /> SeatroniCs, InC. PO BOX 1138 Auburn,WA 98001 253-939-6060 <br />
The URL can be used to link to this page
Your browser does not support the video tag.