My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-12 2018-09-20
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-12
>
3003 W CASINO RD BLDG 45-12 2018-09-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 1:08:21 PM
Creation date
4/30/2018 8:39:21 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-12
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r , <br /> Interior Lighting Sun ary - Building Area 11/lett J LTG-INT-BLD <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address BOEING ED Static Test Bldg Date 9/3/2015 <br /> Lighting Alterations, Renovations &Building Additions For Building Department Use <br /> 0 Less than 60% 0 60%or more 0 Stand alone 0 Addition <br /> Notes: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be <br /> combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. <br /> b.For retrofits and building additions,provide Building Area types and gross interior areas in the <br /> Maximum Allowed Lighting table.If a builidng addition will comply as combined with the overall <br /> existing builidng,include all applicable existing Building Area types and gross interior areas. <br /> c.Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br /> d.If less than 60%of existing fixtures will be replaced,use LTG-INT-SPACE form. <br /> Total Building Performance - No lighting calcs required <br /> Location(plan#, Allowed Gross Interior Watts Allowed <br /> Building Area* room#,or ALL) Area Description Watts per ft2 Area in ft2 (watts/ft2 x area) <br /> Manufacturing All 1.11 110513 122669 <br /> facility <br /> * Select Table C405.5.2(1)Building Area from drop down menu. Total 110513 <br /> Total Building Performance -No lighting calcs required <br /> Location(plan#, Number of Watts/ Watts <br /> Building Area* room#) Fixture Description** Fixtures Fixture Proposed <br /> Manufacturing ALL TYPE Al 108 400 43200 <br /> facility <br /> Manufacturing ALL TYPE A2 44 500 22000 <br /> facility <br /> Manufacturing ALL TYPE B 8 44 352 <br /> facility <br /> Manufacturing ALL TYPE C 26 64 1664 <br /> facility <br /> * Select Table C405.5.2(1)Building Area from drop down menu. <br /> **Include existing to remain lighting and exempt lighting equipment per notes below. <br /> Compliance by Building Area <br /> Total Allowed Total Proposed Interior Lighting Power <br /> Building Area Warnings Watts Watts Allowance <br /> Manufacturing Confirm all fixtures are reported under proposed lighting-low watts 122669 67216 COMPLIES <br /> facility relative to maximum allowed. <br /> Total 122669 I 67216 <br /> Notes: <br /> 1.Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between <br /> Building Area types is not allowed under the Building Area Method compliance path. <br /> 2.Proposed fixtures must be listed in the building area in which they occur. Include ALL proposed lighting fixtures. <br /> 3.For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> 4.For proposed Watts/Fixture,use manufacturer's listed maximum input wattage of the fixture(not simply the lamp wattage)and other criteria <br /> as specified in Section C405.5.1.For line voltage track lighting,list the greater of actual luminaire wattage or length of track multiplied by 50, --- <br /> or as applicable,the wattage of current limiting devices or of the transformer.For low voltage track lighting list the transformer rated wattage. % e <br /> 5.For lighting equipment eligible for exemption per C405.5.1,note exception number and leave Watts/Fixture blank. I <br /> r_ n...............s,...:..s:......a........,...:.,s:..s......,.:., n.. a r;..tia:.....,a,.a,r..:.,a......... s:..s....,.., r.d.....a;t....,..,.,:..s:.....:..s:..s......a....,...:...r:,.., <br />
The URL can be used to link to this page
Your browser does not support the video tag.