My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-12 2018-09-20
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-12
>
3003 W CASINO RD BLDG 45-12 2018-09-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 1:08:21 PM
Creation date
4/30/2018 8:39:21 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-12
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> Lighting, Motor, and T isformer Permit Documen Checklist LTG-CHK <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address BOEING ED Static Test Bldg Date 9/3/2015 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and transformer requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> LIGHTING CONTROLS(Section C405.2) <br /> Indicate on plans the manual control type&locations served; 1E10-10 TO 1E10- <br /> Yes C405.2.1.1 Manual interior 15 <br /> C405.2.1.2 lighting controls Indicate of plans the 50%lighting load reduction method 1E10-10 TO 1E10- <br /> provided or identify exception taken 15 <br /> Indicate lighting system automatic shut-off capability-identify 1E10-10 TO 1E10- <br /> lighting zone areas served on plans; 15 <br /> Automatic time Indicate locations of override switches on plans and the areas 1E10-10 TO 1E1 0- <br /> Yee C405.2.2.1 switch controls and <br /> override switching served,include area sq.ft.; 15 <br /> Indicate locations where automatic shutoff is provided by other 1E10-10 TO 1E1 0- <br /> methods <br /> E10- <br /> methods(occupancy sensor,daylight controls,etc) 15 <br /> Yes C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors 1E10-10 TO 1E10- <br /> 15 <br /> Daylight zones- Indicate vertical fenestration primary and secondary daylight 1E10-10 TO 1E1 0- <br /> Yes <br /> E10- <br /> Yes C405.2.2.3 Vertical fenestration zone areas on plans,include sq.ft.; 15 <br /> and skylights Indicate skylight daylight zone areas on plans,include sq.ft. <br /> Indicate on plans the locations served by daylight zone 1E10-10 TO 1E10- <br /> Yes C405.2.2.3.2 Daylight zone controls; 15 <br /> controls Indicate in plans the lighting load reduction(dimming)method- 1E10-10 TO 1E10- <br /> stepped or continuous dimming 15 <br /> Specific application Indicate on plans the locations served by specific application <br /> NA C405.2.3 lighting controls lighting controls <br /> General <br /> Indicate lighting control method for display and accent lighting, <br /> and display case lighting; <br /> NA C405.2.3- Display and accent <br /> Items 1&2 lighting Indicate these fixtures are controlled independently from both <br /> general area lighting and other lighting applications within the <br /> same space <br /> C405.2.3 Hotel/motel guest Provide a lighting control device at each guest room entry for <br /> NA Item 3 rooms all permanently installed fixtures in guest room; <br /> Indicated whether lighting control is manual or automatic <br /> NA C405.2.3- Supplemental task Provide automatic shut-off vacancy controls for supplemental <br /> Item 4 lighting task lighting,including under-shelf or under-cabinet lighting <br /> Identify eligible non-visual applications and method of lighting <br /> control; <br /> NA C405.2.3- Lighting for non- <br /> NA - - <br /> Item 5 visual applications Indicate these fixtures are controlled independently from both <br /> general area lighting and other lighting applications within the <br /> same space <br /> Indicate lighting control method for lighting equipment for sale <br /> C405.2.3- Lighting equipment or demonstration; <br /> NA for sale or Indicate these fixtures are controlled independently from both <br /> Item 6 demonstration <br /> general area lighting and other lighting applications within the <br /> same space <br /> If egress lighting power density is greater than 0.05W/ft2, 1E10-10 TO 1E10- <br /> C405.2.3 Means of egress indicate method of automatic shut-off during unoccupied 15 <br /> Yes periods; <br /> Item 7 lighting <br /> Identify on plans the egress fixtures that function as both 1E10-10 TO 1E10- <br /> normal and emergency means of egress illumination 15 <br /> C405.10 Cooler and freezer Provide vacancy device or timer to turn off fixtures within 15 <br /> NA minutes of unoccupancy for cooler and freezer lighting fixtures <br /> C405.11 lighting with lamp efficacy less than 40 lumens per watt <br /> Yes C405.2.4 Exterior lighting Indicate on exterior lighting plans the automatic lighting control 1E10-10 TO 1E10- <br /> controls method and locations served 15 <br /> Exterior building Provide motion sensor controls for building grounds fixtures <br /> 1E10-10 TO 1E10- <br /> Yes C405.6.1 grounds lighting rated at greater than 100 watts with lamp efficacy less than 60 15 <br /> controls lumens,or identify exception taken <br /> Identify applicable commissioning documentation requirements <br /> per Section C408 or eligibility for exception; <br /> Lighting system Provide written procedures for functional testing of all <br /> NA C408.3 functional testing automatic controls and describe the expected system <br /> response; <br /> Identify in construction documents the party responsible for <br /> functional testing of automatic lighting controls <br />
The URL can be used to link to this page
Your browser does not support the video tag.