My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-12 2018-09-20
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-12
>
3003 W CASINO RD BLDG 45-12 2018-09-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 1:08:21 PM
Creation date
4/30/2018 8:39:21 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-12
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Seatronics,Inc.Job#111008 BOEING EVERETT 45-12 BLDG.STATIC TEST FACILITY PHASE 2 Acceptance Test Procedure <br /> FIRE ALARM SYSTEM MODIFICATIONS&ADDITIONS Page 2 of 6 <br /> 3.4 After the ATP is satisfactorily completed and all exceptions have been cleared, the <br /> Owner's Representative shall sign the "Approved and Accepted" block. <br /> 3.5 The Contractor's Field Engineer shall be responsible for the organization and <br /> performance of this accepted test. <br /> 3.5.1 The Contractor shall provide all material and equipment required to perform the <br /> test except as noted below: <br /> 4.0 TEST PREPERATIONS <br /> 4.1 EQUIPMENT REQUIRED <br /> 4.1.1 Test gas, Digital Volt Meter <br /> 4.2 TEST CONDITIONS - GENERAL <br /> 4.2.1 Notify interested parties that system tests are beginning. <br /> 4.2.2 Verify that all required system pre-tests have been completed. <br /> 4.2.3 Visually inspect equipment installation to verify proper mounting. <br /> 4.2.4 Verify that the system is in normal supervisory condition (power lamp is "on" and <br /> other lamps and audible devices are "off°). <br /> 5.0 ACCEPTANCE TESTS -ALARM & SUPERVISORY CONDITIONS <br /> 5.1 Verify alarm and supervisory conditions as specified in Table 1. For each alarm condition <br /> listed, the appropriate system response should occur. After initiation of each alarm or <br /> supervisory condition, the following steps should be completed: <br /> 5.1.1 Alarm condition -silence audible alarms (if activated) by pressing Alarm <br /> Acknowledge button, followed by the Alarm Silence button. <br /> 5.1.2 Supervisory condition - silence panel Supervisory audible by pressing <br /> Supervisory acknowledge control button. <br /> 5.1.3 Reset the control panel after the alarm condition system response(s) have been <br /> verified.(Do not reset if the test step specifically indicates not to reset) The <br /> system trouble lamp and audible trouble alarms will be"on". <br /> 5.1.4 Verify the control panel is in normal supervisory condition and all trouble <br /> indications have been cleared. <br />
The URL can be used to link to this page
Your browser does not support the video tag.