transfer relay, and overcurrent protection. Mounts on two of DAA Series Digital Audio Amplifiers: Legacy DAA Series
<br /> four positions on a CHS-4L or CHS-4 chassis. See DN-5952. ampiifiers are compatible with DVC systems running SR4.0.
<br /> ACPS-610• 6.0 A or 10.0 A addressable charging power sup- For specific information on DAA-50 series ampiifiers, refer to
<br /> ply.See DN-60244. DN-7046. For information on DAA-7525 Series, refer to DN-
<br /> 60257.
<br /> FCPS-24S6/-24S8: Remote 6 A and 8 A power supplies with
<br /> battery charger. See DN-6927. COMPATIBLE DEVICES,EIA-232 PoRrs
<br /> BAT Series:Batteries.AMPS-24 uses two 12 volt,7 to 200 AH PRN-7:80-column printer.See DN-60897
<br /> batteries. See DN-6933. VS4095/5: Printer, 40-column, 24 V. Order from Keltron, Inc.
<br /> AUDlO OPTIONS See DN-3260.
<br /> NOTE:See"Enclosures,Chassis,and Dress Plates"on page 6 for DPI-232: Direct Panel Intertace, specialized modem for
<br /> mounting hardware. extending serial data links to remotely located FACPs and/or
<br /> peripherals. See DN-6870.
<br /> DVC-EM:Digital Voice Command,digital audio processor with .
<br /> message storage for up to 32 minutes of standard quality (4 COMPATIBLE DEVICES,ElA-485 PORTS
<br /> minutes at high quality)digital audio. See DN-7045. ACM-24AT:ONYX�Series ACS annunciator-up to 96 points
<br /> DVC-RPU: Digital Voice Command Remote Paging Unit for of annunciation with Alarm or Active LED, Trouble LED, and
<br /> use with DVC-EM. Includes the keypad/display. See DN- switch per circuit.Active/Alarm LEDs can be programmed (by
<br /> 60726. powered-up switch selection) by point to be red, green,or yel-
<br /> DS-DB: Digital Series Distribution Board, provides bulk ampli- low•,the Trouble LED is always yellow.See DN-6862.
<br /> fication capabilities to the DVC-EM while retaining digital audio AEM-24AT: Same LED and switch capabilities as ACM-24AT;
<br /> distribuition capabilities.Can be configured with up to four DS- expands the ACM-24AT to 48,72,or 96 points. See dN-6862.
<br /> AMPs,supplying high-levei risers spread throughout an instal- ACM-48A:ONYX�Series ACS annunciator-up to 96 points
<br /> lation. See DN-60565. of annunciation with Alarm or Active LED per circuit. Active/
<br /> DVC-KD:DVC-EM keypad for local annunciation and controls; Alarm LEDs can be programmed(by powered-up switch selec-
<br /> status LEDs and 24 user-programmable buttons. See DN- tion)in groups of 24 to be red,green,or yellow.Expandab�e to
<br /> 7045. 96 points with one AEM-48A. See DN-6862.
<br /> DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS AEM-48A: Same LED capabilities as ACM-48A; expands the
<br /> requires DS-XF70V step-up transformer. Digital Series Ampli- ACM-48A to 96 points.See DN-6862.
<br /> fier,part of the DS-DB system.See DN-60663. ACM-8R: Remote Relay Module with eight Form-C contacts.
<br /> DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for Can be located up to 6,000 ft. (1828.8 m)from panel on four
<br /> DVC-EM, DS-DB distribution board, and DAA2/DAX Series wires.See DN-3558.
<br /> amplifiers. See DN-60633. LCD-160: Liquid Crystal Display annunciator, 160-character
<br /> DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- backlit.Can store character sets for multiple languages. LCD-
<br /> bly with power supply;includes chassis.See DN-60556. 160C is used for ULC applications.See DN-6940.
<br /> DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier LCD2-S0:Terminal and ACS mode. 80-character,backlit LCD
<br /> assembly with power supply;includes chassis. See DN-60556. display.Mounts up to 6,000 ft.(1828.8 m)from panel.Up to 32
<br /> DAA2-7525(E):75W,25 Vrms digital audio amplifier assembly Per FACP. See LCD2-80(DN-60548).
<br /> with power supply;includes chassis.See DN-60556. SCS Series: Smoke controf station; eight (expandable to 16)
<br /> DAX-3525(E):35W,25 Vrms Digital Audio Amplifier assembly circuits. See DN-4818.
<br /> with power supply,includes chassis.See DN-60561. TM-4:Transmitter Module. Includes three reverse-polarity cir-
<br /> DAX-3570(E)•35W,70.7 Vrms Digital Audio Amplifier assem- cuits and one municipaf box circuit. Mounts in panel module
<br /> bly with power supply,includes chassis. See DN-60561. position (as in single-address mode applications) or in CHS-
<br /> M3 position. See DN-6860.
<br /> DAX-5025(E):50W,25 Vrms Digital Audio Amplifier assembly UDACT 2: Universal Digital Alarm Communicator Transmitter,
<br /> with power supply,includes chassis.See DN-60561. 636 channel.See DN-60686.
<br /> DAX-5070(E):50W,70.7 Vrms Digital Audio Amplifier assem- UZC-256•Programmable Universal Zone Coder provides pos-
<br /> bly with power supply,includes chassis. See DN-60561. itive non-interfering successive zone codin$. Microprocessor-
<br /> TELH-1: Firefighter's Telephone Handset for use with the controlled, field-programmable from IBM -compatibte PCs
<br /> DVC-EM when mounted in the CA-2 chassis.See DN-7045. (requires optional prog�amming kit). Mounts on a CHS-4
<br /> CMIC-1: Microphone used with DVC/DVC-EM. Included with series chassis within NFS2-3030.
<br /> CA-2 chassis assembly.See DN-7045. Con�tPATIBLE INTELUGEIVr DEv►CES
<br /> RM-1/RM-1 SA: Remote microphone assemblies, mount on NOTE`A"suffix indicates ULC-Listed model.
<br /> ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1SA)
<br /> stand-alone cabinets.See DN-6728. FWSG Wireless SWIFT Gateway:Addressable gateway sup-
<br /> ports wireless SLC devices. Not appropriate for ULC applica-
<br /> AA-30: Audio Amplifier, 30 watts,25 Vrms. Includes amplifier tions.See DN-60820.
<br /> and audio input supervision,backup input,and automatic swi-
<br /> tchover,power supply,cables.See DN-3224. FSA-5000:Intelligent FAASI�XS Fire Alarm Aspiration Sens-
<br /> ing Technology. Intelligent aspirating smoke detector for appli-
<br /> AA-120/AA-100: Audio Amplifier. AA-120 is 120 watts, 25 cations up to 5,000 sq.ft. For Canadian applications, order
<br /> Vrms.AA-100 is 100 watts,70.7 Vrms.The amplifier contains FSA-5000A.
<br /> an integral chassis for mounting to a CAB-B4, -C4, or -D4
<br /> backbox(consumes one row).Includes audio input and ampli- FSA-8000: Intelligent FAAS?� XM Fire Alarm Aspiration
<br /> fied output supervision, backup input, and automatic switcho- Sensing Technology. Intelligent aspirating smoke detector for
<br /> ver to backup tone.See DN-3224. applications up to 8,000 sq.ft.For Canadian applications,order
<br /> FSA-8000A.See DN-60792.
<br /> DN-7070:P•3/8/17-Page 5 of 8