Laserfiche WebLink
transfer relay, and overcurrent protection. Mounts on two of DAA Series Digital Audio Amplifiers: Legacy DAA Series <br /> four positions on a CHS-4L or CHS-4 chassis. See DN-5952. ampiifiers are compatible with DVC systems running SR4.0. <br /> ACPS-610• 6.0 A or 10.0 A addressable charging power sup- For specific information on DAA-50 series ampiifiers, refer to <br /> ply.See DN-60244. DN-7046. For information on DAA-7525 Series, refer to DN- <br /> 60257. <br /> FCPS-24S6/-24S8: Remote 6 A and 8 A power supplies with <br /> battery charger. See DN-6927. COMPATIBLE DEVICES,EIA-232 PoRrs <br /> BAT Series:Batteries.AMPS-24 uses two 12 volt,7 to 200 AH PRN-7:80-column printer.See DN-60897 <br /> batteries. See DN-6933. VS4095/5: Printer, 40-column, 24 V. Order from Keltron, Inc. <br /> AUDlO OPTIONS See DN-3260. <br /> NOTE:See"Enclosures,Chassis,and Dress Plates"on page 6 for DPI-232: Direct Panel Intertace, specialized modem for <br /> mounting hardware. extending serial data links to remotely located FACPs and/or <br /> peripherals. See DN-6870. <br /> DVC-EM:Digital Voice Command,digital audio processor with . <br /> message storage for up to 32 minutes of standard quality (4 COMPATIBLE DEVICES,ElA-485 PORTS <br /> minutes at high quality)digital audio. See DN-7045. ACM-24AT:ONYX�Series ACS annunciator-up to 96 points <br /> DVC-RPU: Digital Voice Command Remote Paging Unit for of annunciation with Alarm or Active LED, Trouble LED, and <br /> use with DVC-EM. Includes the keypad/display. See DN- switch per circuit.Active/Alarm LEDs can be programmed (by <br /> 60726. powered-up switch selection) by point to be red, green,or yel- <br /> DS-DB: Digital Series Distribution Board, provides bulk ampli- low•,the Trouble LED is always yellow.See DN-6862. <br /> fication capabilities to the DVC-EM while retaining digital audio AEM-24AT: Same LED and switch capabilities as ACM-24AT; <br /> distribuition capabilities.Can be configured with up to four DS- expands the ACM-24AT to 48,72,or 96 points. See dN-6862. <br /> AMPs,supplying high-levei risers spread throughout an instal- ACM-48A:ONYX�Series ACS annunciator-up to 96 points <br /> lation. See DN-60565. of annunciation with Alarm or Active LED per circuit. Active/ <br /> DVC-KD:DVC-EM keypad for local annunciation and controls; Alarm LEDs can be programmed(by powered-up switch selec- <br /> status LEDs and 24 user-programmable buttons. See DN- tion)in groups of 24 to be red,green,or yellow.Expandab�e to <br /> 7045. 96 points with one AEM-48A. See DN-6862. <br /> DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS AEM-48A: Same LED capabilities as ACM-48A; expands the <br /> requires DS-XF70V step-up transformer. Digital Series Ampli- ACM-48A to 96 points.See DN-6862. <br /> fier,part of the DS-DB system.See DN-60663. ACM-8R: Remote Relay Module with eight Form-C contacts. <br /> DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for Can be located up to 6,000 ft. (1828.8 m)from panel on four <br /> DVC-EM, DS-DB distribution board, and DAA2/DAX Series wires.See DN-3558. <br /> amplifiers. See DN-60633. LCD-160: Liquid Crystal Display annunciator, 160-character <br /> DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- backlit.Can store character sets for multiple languages. LCD- <br /> bly with power supply;includes chassis.See DN-60556. 160C is used for ULC applications.See DN-6940. <br /> DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier LCD2-S0:Terminal and ACS mode. 80-character,backlit LCD <br /> assembly with power supply;includes chassis. See DN-60556. display.Mounts up to 6,000 ft.(1828.8 m)from panel.Up to 32 <br /> DAA2-7525(E):75W,25 Vrms digital audio amplifier assembly Per FACP. See LCD2-80(DN-60548). <br /> with power supply;includes chassis.See DN-60556. SCS Series: Smoke controf station; eight (expandable to 16) <br /> DAX-3525(E):35W,25 Vrms Digital Audio Amplifier assembly circuits. See DN-4818. <br /> with power supply,includes chassis.See DN-60561. TM-4:Transmitter Module. Includes three reverse-polarity cir- <br /> DAX-3570(E)•35W,70.7 Vrms Digital Audio Amplifier assem- cuits and one municipaf box circuit. Mounts in panel module <br /> bly with power supply,includes chassis. See DN-60561. position (as in single-address mode applications) or in CHS- <br /> M3 position. See DN-6860. <br /> DAX-5025(E):50W,25 Vrms Digital Audio Amplifier assembly UDACT 2: Universal Digital Alarm Communicator Transmitter, <br /> with power supply,includes chassis.See DN-60561. 636 channel.See DN-60686. <br /> DAX-5070(E):50W,70.7 Vrms Digital Audio Amplifier assem- UZC-256•Programmable Universal Zone Coder provides pos- <br /> bly with power supply,includes chassis. See DN-60561. itive non-interfering successive zone codin$. Microprocessor- <br /> TELH-1: Firefighter's Telephone Handset for use with the controlled, field-programmable from IBM -compatibte PCs <br /> DVC-EM when mounted in the CA-2 chassis.See DN-7045. (requires optional prog�amming kit). Mounts on a CHS-4 <br /> CMIC-1: Microphone used with DVC/DVC-EM. Included with series chassis within NFS2-3030. <br /> CA-2 chassis assembly.See DN-7045. Con�tPATIBLE INTELUGEIVr DEv►CES <br /> RM-1/RM-1 SA: Remote microphone assemblies, mount on NOTE`A"suffix indicates ULC-Listed model. <br /> ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1SA) <br /> stand-alone cabinets.See DN-6728. FWSG Wireless SWIFT Gateway:Addressable gateway sup- <br /> ports wireless SLC devices. Not appropriate for ULC applica- <br /> AA-30: Audio Amplifier, 30 watts,25 Vrms. Includes amplifier tions.See DN-60820. <br /> and audio input supervision,backup input,and automatic swi- <br /> tchover,power supply,cables.See DN-3224. FSA-5000:Intelligent FAASI�XS Fire Alarm Aspiration Sens- <br /> ing Technology. Intelligent aspirating smoke detector for appli- <br /> AA-120/AA-100: Audio Amplifier. AA-120 is 120 watts, 25 cations up to 5,000 sq.ft. For Canadian applications, order <br /> Vrms.AA-100 is 100 watts,70.7 Vrms.The amplifier contains FSA-5000A. <br /> an integral chassis for mounting to a CAB-B4, -C4, or -D4 <br /> backbox(consumes one row).Includes audio input and ampli- FSA-8000: Intelligent FAAS?� XM Fire Alarm Aspiration <br /> fied output supervision, backup input, and automatic switcho- Sensing Technology. Intelligent aspirating smoke detector for <br /> ver to backup tone.See DN-3224. applications up to 8,000 sq.ft.For Canadian applications,order <br /> FSA-8000A.See DN-60792. <br /> DN-7070:P•3/8/17-Page 5 of 8 <br />