on a half-chassis and one NFS2-3030 or NCA-2 mounted on a ABF-4B Annunciator Flush Box <br /> half-chassis. The right side houses a microphone/handset ABS-1T6(C)Annunciator Surface Box <br /> well.The CA-2 assembly includes CMIC-1 microphone.ADDR ABS-1 B(C)Annunciator Surface Box <br /> Series doors with two-tier visibility are available for use with <br /> the CA-2 configuration: ADDR-B4, ADDR-C4, ADDR-D4 ABS-26 Annunciator Surface Box <br /> {below). ABS-2D(C)Annunciator Surface Box <br /> ADDR-B4:Two-tier-sized door designed for use with the CA-2 ABS-4D(C)Annunciator Surface Box <br /> chassis configuration.ADDR Series doors are similar to CAB- SEISKIT CAB: Seismic mounting kit. Required for seismic- <br /> 4 Series "DR" doors, but a clear window space exposes the certified applications with NFS2-3030 and other equipment <br /> top two tiers of the CAB-4 enclosure.Use an SBB-B4 backbox mounted in CAB-4 Series Enclosures.includes battery bracket <br /> with the ADDR-B4.See DN-7045,DN-6857. for two 26 AH batteries. • <br /> ADDR-C4:Three-tier-sized door designed for use with the CA- SEISKIT LBB: Seismic kit for the NFS-LBB. includes battery <br /> , 2 chassis configuration. ADDR Series doors are similar to bracket for two 55 AH batteries. <br /> CAB-4 Series"DR"doors, but a clear window space exposes <br /> the top two tiers of the CAB-4 enclosure. Use an SBB-C4 OTHER OPTIONS <br /> backbox with the ADDR-C4. See DN-7045,DN-6857. 411:Slave digital alarm communicator.See DN-6619. <br /> ADDR-D4:Four-tier-sized door designed for use with the CA-2 411 UDAC: Digital alarm communicator.See DN-6746. <br /> chassis configuration.ADDR Series doors are similar to CAB- IPDACT 2, IPDACT Internet Monitoring Module• Connects <br /> 4 Series "DR" doors, but a clear window space exposes the to primary and secondary DACT telephone output ports for <br /> top two tiers of the CAB-4 enclosure.Use an SBB-D4 backbox internet communications over customer-provided Ethernet <br /> with the ADDR-D4.See DN-7045,DN-6857. connection. Requires compatible Teldat VisorALARM Central <br /> DPA-1:Dress panel,used with the CA-1 chassis when config- Station Receiver.Can use DHCP or static IP.See DN-60408. <br /> ured with a DVC-EM, DVC-KD,and CMIC-1.See DN-7045. �pCHSKiT: IP Communicator Chassis Mounting Kit For <br /> DPA-2:Dress Panel used with the CA-2 chassis assembly. mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 <br /> DPA-1A4: Dress panel, used with the CA-1 chassis when the series chassis.Use IPENC for external mounting applications. <br /> CMIC-1 is not used. Provides mounting options on right two IPSPLT:Y-adapter option allow connection of both panel dialer <br /> bays for two ACS annunciators, or for blank plates. See DN- outputs to one IPDACT-2/2UD cable input. <br /> 7045. IPENC: Extemal enclosure for IPDACT, includes IPBRKT <br /> ADP-46:Annunciator dress plate. Mounts in rows 2,3 or 4 of mounting bracket;Red;for black,order IPENC-B. <br /> a CAB-4 series enclosure. Used with ACS series annuncia- �pGSM-4G:Internet and Digital Cellular Fre Alarm Communica- <br /> tors. tor.Provides selectable configurable paths:cellular only,IP only, <br /> BMP-1:Blank module for unused module positions. or fP primary with cellular backup.Connects to the primary and <br /> DP-1B: Blank dress panel. Provides dead-front panel for secondary ports of a DACT. For Canadian applications order <br /> unused tiers;covers DAA2/DAX series or AA-series amplifier. �PGSM-4GC.See DH-60769. <br /> BP2-4•Battery plate,required. NOTE:For other options including compatibility with retrofit equip- <br /> - ment,refer to the pane!'s installation manual,the SLC manual,and <br /> CHS-4�: Low-profile four-position Chassis. Mounts two AA-30 the Device Compatibility Document. � <br /> amplifiers. <br /> • CHS-4N:Chassis for mounting up to four APS-6Rs. System Specifications <br /> CHS-6: Chassis used with the XP6 and XP10 Multi-Modules. SrS7eht CAPaCITY <br /> Mounts up to six modules in any CAB-4 series row. • Intelligent Signaling Line Gircuits...........1 expandable to 10 <br /> NFS-LBB: Battery Box.The NFS-LBB is used to mount up to . Intelligent detectors..........................................159 per loop <br /> two 55 AH batteries. Dimensions: Box: 24" (610 mm) wide x . Addressable monitor/control modules..............159 per loop <br /> 14"(356 mm)high x 7.75"(197 mm)deep. Door:24.125"(613 <br /> mm)wide x 14.25"(362 mm)high;door adds 0.0625"(approx. • Programmable software zones.............................over 2000 <br /> 1.6 mm)to depth. • ACS annunciators <br /> BACKBOXES per CPU2-3030.......................32 address x 64 or 96 points <br /> NOTE.•"C'suffix indicates ULGListed modeL NOTE: The CPU2-3030 can support up to 96 annunciator <br /> address points per ACM-24AT/-48A. <br /> BB-100: Backbox for batteries and power supplies. The BB- <br /> 100 is used to mount up to two 100 AH batteries and power SPECIF/CATIONS <br /> supply,if needed.30"(76.20 cm)wide x 25"(63.50 cm)high x Primary Input Power: <br /> 7.5"(19.05 cm)deep;depth includes door. -AMPS-24: 110-120 VAC,50/60 Hz,4.5 A maximum. <br /> BB-200: Backbox for batteries and power supplies. Holds up -AMPS-24E:240 VAC,50/60 Hz,2.25 A maximum. <br /> to four 100 AH batteries(200 AH capacity)and power supply. DC Output- <br /> 30"(76.20 cm) wide x 36" (91.44 cm) high x 7.5" (19.05 cm) ' <br /> deep;depth includes door. -Main 24 VDC:Up to 5.0 A <br /> BB-UZC: Backbox for housing the UZC-256 for applications -Aux 24 VDC:Up to 5.0 A <br /> where the UZC will not fit in panel enclosure. Black; for red, -5 VDC:Up to 0.15 A. <br /> order BB-UZC-R.See DN-3404. Current draw(Standby/Alarm): <br /> ABF-1 B(C)Annunciator Flush Box -CPU2-3030D board:0.340 A. <br /> ABF-1DB(C)Annunciator Flush Box with Door.UUULC Listed. _CPU2-3030ND board:0.120 A. • <br /> ABF-2B Annunciator Flush Box -LCM-320:0.130 A. <br /> ABF-2D8(C)Annunciator Flush Box with Door -LEM-320:0.100 A. <br /> DN-7070:P•3/8/17-Page 7 of 8 <br />