Laserfiche WebLink
. �. <br /> Model 5495 <br /> Distributed Power Module <br /> Model 5495 Block Diagram <br /> Signal Circuit Output Signal 1 Signal 1 <br /> Input <br /> Distributed Signal 2 <br /> Signal Circuit Output Signal 2 power � <br /> Input Module 5495 Signal 3 <br /> � (Optional) <br /> Signal4 <br /> 12Q V'AC Aux. Power <br /> Trouble Output <br /> Local Fire Control {Alternativ�to notific�tion <br /> circuit trouble.} <br /> Supervision Current: Input <br /> The 5495 supervises a variety of Standby 75 mA voltage range: 9-32 VDC <br /> functions including: Alarm 205 mA Battery charging <br /> • Low AC power Auxiliary capacity: 35.0 AH <br /> • Low battery condition power circuit: 1 Ambient temp.: 32°to 120° F <br /> • Earth ground fault Notification (0° to 49° C) <br /> • Auxiliary output power limit circuits: 4 Mechanical <br /> condition Output Dimensions: 12.25" W x 16" H x <br /> • EOL supervision trouble or configuration: 2 Class A(Style Z) 3" D (30.88 cm W <br /> power limited condition at an 4 Class B (Style Y) x 40.64 cm H x <br /> output (1 Class A& 7.62 D cm) <br /> When a trouble condition occurs, 2 Class B) Indicator Lights � <br /> the 5495 creates a trouble Amps per AC power on : Green <br /> • condition on the host control signal <br /> circuits to which it is connected.the output circuit: 3.0 (6.0 amps total) gattery trouble: Yellow <br /> 5495 still maintains the ability to be Noti�cation Ground fault: Yellow <br /> activated by the host control. In circuit output: 20.4 to 27.3 VDC Aux trouble: Yellow <br /> addition, the 5495 provides a Form @ 3.0 amps each, <br /> C trouble relay output as an 4.7 kS2 EOL Output troubles (1-4): Yeliow <br /> alternative to using the notification resistor required Ordering Information <br /> circuit trouble. on each Class B 5495 Distributed Power Module <br /> Electrical Specification <br /> circuit <br /> AC input: 120 VAC at 2 amps <br /> No. of inputs 2 <br /> Input <br /> Output: 24 VDC at 6 amps configuration: 2 Class B or 2 <br /> , Class A <br /> SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA <br /> KNIGHT keep our product information up-to-date and accurate.We cannot cover all <br /> specific applications or anticipate all requirements.All specifications are FORM#350395 Rev D <br /> subject to change without notice.For more information,contact Silent Knight O 2010 Honeywell International Inc. <br /> by Honeywell 12 Clintonville Road,Northford,CT 06472-7161 Phone:(800)328-0103, <br /> Fax:(203)484-7118.www.silentknight.com <br />